Original source · versioned page text
ADAMS+SPARKES Response to Information Request (Gympie Tce) 160401
Attached to the e-mail Response to Information Request - MCU16/0138.
The original of this document is very large (12.8 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
PROPOSED DUPLEX DEVELOPMENT APPLICATION NO. 111 & 113 GYMPIE TERRACE, NOOSAVILLE PROPOSED STREET FRONT PERSPECTIVE GENERAL INFORMATION Minimum Design Standards Wall Construction Glazing Construction Construction of this building to be in Wall framing to be constructed in Powdercoated Aluminum Frame accordance with the following Australian accordance with engineering specification Windows in accordance with AS 4055 governing bodies. and must not differ from certification "wind loads for residential" & AS 1288 covered by the Form 15. Cladding systems "Glass in Buildings selection and ♦ National Construction Code (NCC) to be fixed in accordance with installation" ♦ Queensland Development Code manufactures specification. ♦ Standard Building Regulation 2006 Site Plan Notes Waterproofing & water Resistant ♦ Local government planning policies Surface water drainage must be prevented Materials PROPOSED NO. 111 PERSPECTIVE from entering the building with FGL sloping All wet area waterproofing is to away from the building & finished slab levels. comply with AS3740, waterproofing Wet Areas The builder is responsible to check all existing wet areas in residential buildings. Floors in "Wet Areas" to be impervious in services prior to beginning construction. NCC Vol2 P3.8.1.0 accordance with Australian Standards. Finish and fall gradients to floor wastes. Position of proposed building to Roof Construction be verified by builder on site. Colorbond sheet metal to be fixed in Location of existing services to be accordance with manufactures verified by builder prior to construction. specification. All ridge capping, steps, hips valleys and Soffit Construction vent flashings to provide waterproofing 4.5mm F.C Sheeting and Painted system. PROPOSED NO. 113 PERSPECTIVE C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only. Revision Schedule Client Name: The Property Clinic Revision Number Revision Description Revision Date Issued by Project Address: No. 113 Gympie Terrace, Noosaville Sheet Number:01 Project Number:16-024 A DA Set 1.0 07/03/2017 B.Hunt Climate Zone: 2 Wind Category: To engineers spec. Development Perspectives Phone: 0488209840 email: [email protected] Project Issue Date: 07/03/2017 Project Status: DA Set 1.0 - RFI Scale: 1 : 100 website: www.iconbuildingdesign.com.au Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.