Council archive · source document
Minor Change Existing Approval - 132007.2399.03 (AS PUBLISHED)
Frontage Works
27. If any necessary footpath improvements such as topsoiling, grassing, and tree planting are
required to the Links Drive frontage of the site as a result of roadworks and to achieve
required sightlines, those works shall be in accordance with Planning Scheme Policy PSP03
Landscaping Plants & Guidelines.
28. A new 1.5 m wide concrete path shall be constructed along one side all of the road from
Links Drive to Lot 27on the site in accordance with Council’s design standards and shall
connect to the existing pathway on Links Drive.
29. Pram ramps shall be installed on the Links Drive pathway at the location of the pedestrian
refuge that is to be constructed on the leg of the roundabout servicing the proposed
development.
30. All paths, pram ramps, driveways and parking areas shall be designed and constructed to
ensure pedestrian safety using non-slip materials, to produce an evenly graded surface
finish, and to be in accordance with the Disability Discrimination Act 1992 and Australian
Standard 1428.1 Design for Access & Mobility.
31. All redundant vehicular crossings to the site shall be removed and replaced by kerb &
channel, footpath paving and landscaping such as trees and grasses in accordance with
Council’s Standard specifications prior to commencement of the use permitted by this permit.
Car Parking
32. Carparking shall be provided within the site as shown on Plan M1806-11A dated 7 November
2007 as submitted by Jones Flint & Pike except as modified herein for at least 14 spaces.
The carparking area shall be designed to comply with the provisions of AS 2890.1-2004 for
user class 1. The minimum head clearance (headroom) at any point shall be 2.3m.
33. The carparking area shall be drained and the pavement constructed to access road
standards. Plans and specifications for these works shall be submitted in conjunction with
an application for a Development Permit for Operational Works.
34. All carparking shall be kept maintained and line-marked in a condition fit for use, or delineated
in another approved manner, to the reasonable satisfaction of Council.
Power
35. An underground electricity service shall be provided to each lot.
In this regard, an approved ENERGEX Electrical Design Consultant shall work in conjunction
with Council’s Manager - Works Support to prepare detailed designs of the electrical
proposal.
The detailed designs shall then be submitted to ENERGEX for approval and a copy of their
approval submitted to Council in conjunction with a “Certificate of Electricity Supply for
Proposed Subdivisions” (prepared by an approved ENERGEX Electrical Design Consultant)
prior to Council endorsing the Plan of Survey.
Any agreement with ENERGEX or an approved ENERGEX Electrical Design Consultant
shall be wholly at the applicant’s expense and shall not entail a financial encumbrance on
future purchasers of the proposed lots.
36. Street lighting and pathway lighting throughout the subdivision shall have a high energy
efficient rating to the reasonable satisfaction of Council and shall generally be provided in
accordance with the principles of Council’s Engineering Design Standards.
Telecommunication
37. The requirements for TELECOMMUNICATION services shall be satisfied in relation to the
provision of new underground telephone services to the proposed lots. In this regard written
confirmation from an approved telecommunication agency shall be submitted to the Council
prior to Council endorsing the Plan of Survey.
Page 6 of 19
Document Set ID: 24764739
Version: 6, Version Date: 18/05/2026
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Minor Change Existing Approval - 132007.2399.03 (AS PUBLISHED).pdfRelated documentApplication case desk ↗
About this file
- File size
- 216 KB (small file)
- File type
No other editions are linked here.