Council archive · source document
Minor Change Existing Approval - 132007.2399.03 (AS PUBLISHED)
45. All stormwater drainage lines including inter-allotment drainage shall be inspected by closed
circuit television (CCTV) prior to commencement of the approved Use.
CCTV inspection will be carried out by Council's CCTV contractor and arranged by Council
following satisfactory completion of construction works. The developer will be responsible
for the full cost of CCTV inspection, including any additional inspection necessary following
defect identification and rectification. This charge is payable prior to the issue of Operational
Works approval and will be determined on the unit rate basis current at the time of approval.
Sewer Mains
46. Prior to endorsement of the Plan of Survey for Stage 1, the new parcel shall be connected
to Council’s existing sewerage reticulation systems and be constructed in accordance with
Council’s standards and requirements at no cost to Council. This work may be covered by
an uncompleted works bond at 150% of the value of the connection that can be in place for
a duration agreed to by the Manager Land Development.
47. Prior to endorsement of the Plan of Survey for Stage 2, the existing sewer main, rising main
and effluent main that traverse the site shall be relocated generally in accordance with Tate
Professional Engineers drawing No. C1732/07/J/P04 dated 19/11/07.
48. Prior to endorsement of the Plan of Survey for Stage 2, if required the applicant shall upgrade
any existing sewer services (including pumps or pump station) at no cost to Council.
49. To ensure Council’s sewer main is accessible for maintenance purposes and is protected
from risk of damage no structures requiring a building permit (eg. buildings, swimming pools,
retaining walls exceeding 1m in height, raised terraces, etc) shall be constructed within this
‘zone of influence’ or within 1.5m of the centreline of the sewer main, whichever is the greater.
As such the applicant shall amend Operational Works plans including Building plans to
ensure compliance.
50. Design for a sewerage system to connect all new lots within the site to Council's existing
sewerage reticulation system shall be to the standards and requirements set out in Council’s
Engineering Design Standards. If the design requires the construction of a pump station and
a rising main, the connection point to Council's existing system will be nominated by the
Manager - Land Development.
51. All connections to sewer system shall be carried out either by Council or by a Council
approved Contractor and at no cost to Council.
Town Water Supply
52. The site shall be connected to Council’s existing town water supply and be constructed in
accordance with Council’s standards and requirements at no cost to Council.
53. Prior to endorsement of the Plan of Survey for Stage 1, the newly created parcel shall have
a single water connection to the water reticulation system, which shall extend to the property
boundary and be metered. This work may be covered by an uncompleted works bond at
150% of the value of the connection that can be in place for a duration agreed to by the
Manager Land Development.
54. Prior to endorsement of the Plan of Survey for Stage 2. the development shall be served by:
• A single Body Corporate water meter to measure the total water consumption
(including fire hose reels, but excluding fire hydrants and fire sprinkler systems), and
• Individual water meters to each tenement capable of being separately rated, and
• A fire service (fully testable single detector check with metered bypass), where
applicable, for flows to fire hydrants and fire sprinkler systems (excluding fire hose
reels).
55. All fees for the supply of water meters shall be paid to the Council.
Page 8 of 19
Document Set ID: 24764739
Version: 6, Version Date: 18/05/2026
See the original