Original source · versioned page text
SUPESEDED - Preliminry Amended plans - MCU19-0143
Plans and drawings: the text below has words only, no drawings.
Original PDF page 13, section 1. The text section number identifies this passage in the reader.
NOTE: ALL ADJACENT EXTERNAL WALLS
TO COMPLY WITH NCC VOL 2 2019 - -
PART 3.7.2 - FIRE SEPARATION OF EXTERNAL PRELIMINARY APPROVED PLAN
WALLS AND PART 3.7.2.4 - CONSTRUCTION MCU19/0143 & OPW19/0264
OF EXTERNAL WALLS AND BE FRL 60/60/60. NOOSA COUNCIL
ROOFING, FASCIA, GUTTER AND EAVES
LININGS TO BE OF A NON COMBUSTIBLE 26 FEBRUARY 2020
MATERIAL. -
VILLA 2 Trimdeck roof sheet,
Colorbond fascia/gutter fixed
VILLA 1 Trimdeck roof sheet,
Colorbond fascia/gutter fixed
as per manufacturer's as per manufacturer's
specifications specifications
Metal roof battens
External wall sarking/insulation fixed to manufacturer's Roof/ceiling
as per builders specification specifications insulation as
Metal roof battens Roof trusses/rafters - as per per builder's
900 Eaves fixed to manufacturer's engineer/manufacturer's specification
Aluminium specifications design & specifications
framed windows - installed 600 Eaves
as per manufacturer's F.C sheet
specifications to raked All External claddings
600
eaves to be installed as per
4.5 pitch manufacturer's
4.5 Pitch
specifications
600
Ceiling Ceiling
Joinery Joinery
Balustrade
1000 Balustrade
2700
Void Lounge Dine Lounge Dine
2700
2400
2400
1000
F.F.L F.F.L
Ceiling Garage
Garage Ceiling
Joinery 10mm plasterboard
to ceiling/walls Joinery
Entry Metal ceiling battens
Villa 1
3000
3600
Entry Hall Bed 2 Garage
2400
3000
Balustrade
1000
G.F.L DPC
900
Garage F.L
900
DPC
LB
100
G.L
Plasterboard direct Slab
G.F.L slab 225mm Min
Footing & Slab design to fixed to blockwork
to be infilled into
190mm C.M.B engineer's specifications and
base walls details
TYPICAL SECTION 1
Scale: 1:100
Refer to engineer's design Note: Termite Protection of
and specifications for all the building to be in accordance
timber framing, tie downs, with AS3660 - Protection of
bracing and connection details. buildings from Subterranean
FOR CONSTRUCTION Termites.
No. Description Date Tracy Dowden - Building Designer Client: Richard & Jodie Thomas
Section 1
19/12/2019 11:32:14 AM
15 Prelim WD's Rev 1 28/10/19
16 Prelim WD's Rev 2 6/11/19 QBCC: 1009413 Description Proposed duplex
17 For Construction WD's 11/11/19 Project number 5VEN
18
19
For Construction WD's Rev 1
For Construction WD's Rev 2
12/12/19
16/12/19
Site Address: 5 Ventura St
Sunrise Beach Qld
Date 22/4/19 A117
Drawn by T.D
20 For Construction WD's Rev 3 19/12/19
QBCC Lic 1184982 Checked by T.D Scale 1 : 100
THIS DESIGN REMAINS THE COPYRIGHT OF THE DESIGNER.