C2. Eng Report
Attached to the e-mail Response to Information Request - MCU17/0572 & OPW17/0611.
Original PDF page 181, section 1. The text section number identifies this passage in the reader.
LEGEND
IT'S HOW
WE CONNECT
For more info contact a Telstra Accredited Locater or Telstra Plan Services 1800 653 935
Exchange
(major cable present)
BK
—Lait—_
@ or &
C4
Footway access chamber
(can vary from 1-lid to 12-lid)
Pillar/cabinet
(above the ground / free standing)
Above ground complex equipment
housing (eg RIM)
Please Note: This equipment is
powered by 240V electricity.
oc other carrier
TP20
{ <—\— 2 pair lead-in to property
from pit in street
O59 <— 1 pair working (pair ID 059)
1DEAD 1 pair dead (i.e. spare, not connected)
107
<
on Se Qe 888
P100 (Attached text denotes conduit type and sce)
Single to multiple round conduit
Configurations 1, 2, 4, 9 respectively
Multiple square conduit
Cer EH e EH Confgurations 2, 4, 6 respectively
E85 (Attached text denotes conduit type and sze)
Cable jointing pit
(number indicating pit type)
—@)—
©
Elevated cable joint
(above ground joint on buried cable)
——}—_ Telstra Plant in shared utility trench
Aerial Cable
(above ground)
—_»A— Aerial Cable
(attached to joint use pole e.g. power)
Direct buried cable
®
@
—sSmoOF +— Optical fibre cable direct buried
Marker post installed
Buried transponder
Marker, transponder
Some examples of conduit type and size:
A - Asbestos cement, P - PVC / plastic, C - Concrete,
Gl - Galvanised iron, E - Earthenware.
Condutt sizes nominally range from 20mm to 100mm.
P50 50mm PVC conduit
P100 100mm PVC conduit
A100 100mm asbestos cement conduit
£85 85mm square earthenware conduit
Some examples of how to read Telstra plans:
- 50-
pe a
P50 20.0
3
P100
AA -[eadie nd Or}
AS -[ea0le nD maton]
BA - [cable NO maor}
oO
C100
One 50mm PVC conduit (P50) containing a 50-pair and a 10-pair cable
between two 6-pits, 20.0m apart, with a direct buried 30-pair cable
along the same route.
Two separate conduit runs between two footway
access chambers (manholes) 245m apart. A
nest of four 100mm PVC conduits (P100)
containing assorted cables in three ducts (one
\
ue z od
245.0
being empty) and one empty 100mm concrete
duct (C100) along the same route.
WARNING: Telstra plans and location information conform to Quality Level 'D' of the Australian Standard AS 5488
- Classification of Subsurface Utility Information. As such, Telstra supplied location information is indicative only.
Spatial accuracy is not applicable to Quality Level D. Refer to AS 5488 for further details. Telstra does not warrant
or hold out that its plans are accurate and accepts no responsibility for any inaccuracy shown on the plans.
FURTHER ON SITE INVESTIGATION IS REQUIRED TO VALIDATE THE EXACT LOCATION OF TELSTRA
PLANT PRIOR TO COMMENCING CONSTRUCTION WORK. A plant location service is an essential part of the
process to validate the exact location of Telstra assets and to ensure the assetis protected during construction
works. The exact position of Telstra assets can only be validated by physically exposing it. Telstra will seek