Council archive · source document
22-0097 Structural Issue B(2)(2) · MCU22/0085
Attached to the e-mail Combined Application MCU22/0085 & OPW22/0139 - DA Form 1 - Plans - Owners Consent - Form 15 - 63 the Peninsula Noosaville - Signed.
FLOOR FRAMING SCHEDULE:
MARK SIZE DESCRIPTION
BR1 152x76x6.0 Rectangular Hollow Section Bearer (continuous span)
(Alloy & Temper - 6061/T6)
BR2 152x76x6.0 Rectangular Hollow Section Bearer (continuous span)
(Alloy & Temper - 6061/T6)
BR3 152x76x6.0 Rectangular Hollow Section Bearer (cont. span)
(Alloy & Temper - 6061/T6)
DJ1 200x50x3.0 Rectangular Hollow Section Deck Joist (continuos span)
(Alloy & Temper - 6060/T5 or 6106/T6)
SJ1 200x50x3.0 Rectangular Hollow Section Structural Joist (continuos span)
(Alloy & Temper - 6060/T5 or 6106/T6)
SJ2 200x50x3.0 Rectangular Hollow Section Structural Joist (continuos span)
(Alloy & Temper - 6060/T5 or 6106/T6)
TR1 2/200x50x3.0 Rectangular Hollow Section Trimmer
(Alloy & Temper - 6060/T5 or 6106/T6)
ST1 80x50x6.0 Rectangular Hollow Section Strut
(Alloy & Temper - 6060/T5 or 6106/T6)
C1 315Ø Jetted Concrete Piles Column
NOTES:
1. All floor joists to be at 450mm crs UNO.
315 outer diameter tube.
Filled with concrete, N50/20.
NOTE: Provide 6/N12 bars
All fixings, connectors, plates and angles and R10 helix with 150mm pitch.
to be Stainless Steel grade 316.
Property Boundary
NOTE:
All Steel to be protected
Approx Broadwater Bottom
as per AS/NZS 2312.1
NOTE: Cantilevered decking must not
All dissimilar metals to be be fixed to revetment wall.
Aluminum plate to end of jetty Hidden line indicates
isolated to prevent corrosion as specified by builder. location of ST1. Typical.
(Typical)
SJ1 DJ1
BR1 C1
C1
BR2 C1
C1
TBC by specilist contractor
BR1
(Typical)
SJ2
BR3
C1
65mm
315 outer diameter tube.
cover
Filled with concrete, N50/20.
Provide 6/N12 bars
TR1
DJ1
and R10 helix with 150mm pitch.
Similar to 'C'
C1
315mm Ø
Property Boundary
(Typical)
Pile depth to be confirmed with
specilist contractor and install piles
achieve minimum working loads:
315mm Ø Vertical load capacity - 21kN
Horizontal load capacity - 4kN
Confirm depth with engineer prior to construction
C1 - 315Ø PILE REINFORCEMENT
Issue Made By Date Description PROPOSED PONTOON Scale : 1:100 / 1:10 NOTES:
A JVB 09/03/22 Issue for construction
at No.65 THE PENINSULA, NOOSAVILLE
REVISION
B LF 14/03/22 BR1, BR2 & BR3 specification amended Job No.: 22-0097 1. Do not scale drawings.
2. Scale is correct at A3.
CLIENT: PONTOON WORKS
Dwg No.: S02 3. Check and verify all dimensions
Designed By : L. FRASER BEng (Civil) (Hons) GradIEAust Drawn By : JVB Date : 09/03/22 prior to commencement of work.
Certified By : B.R. CROMAR BEng (Civil) MIEAust CPEng RPEQ NER Date : 09/03/22 Ph: (07) 5444 5578 Email: [email protected] BEARER & JOISTS LAYOUT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
22-0097 Structural Issue B(2)(2).pdfRelated documentApplication case desk ↗
About this file
- File size
- 155 KB (small file)
- File type
No other editions are linked here.