Council archive · source document
Approved Plans - 132000.200173.1
Plans and drawings: the text below has words only, no drawings.
Very large file (10.1 MB): may take a few minutes to open.
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
1 2 3 4 5 6 7
3,000 4,120 890 2,100 900 6,280
8M conc TIM DP FG FG BAL MR REN AFW ASD FG CS AL TIM AS conc AFW
note - 8.0M height line
measured at line of
8M
section cut EXT. FINISHES LEGEND
T.O.W R.L 32.730 AFD aluminium framed door.
10.00°
AFW aluminium framed window.
glazed roof
AL aluminium louvres, refer sched.
UPPER LEVEL 5.00° UPPER LEVEL
FFL 31.730 FFL 31.730 AS aluminium screen.
ref. det. ref. det.
REN aluminium sliding door.
ref. det. ref. det.
ASD
ref. det.
BAL1 balustrade-(no refers to type).
CS BLK masonry blockwork.
SP AFW W16 sliding door dock W14(b) W14(a) inv. corner W10 SBJ C carpet
T.O.W R.L 29.635
conc reinf. concrete wall/pool shell
TIM
TERRACE TIM FORMAL DINING BBQ DINING TIM WT
BAL CS concrete slab.
2,700
2,700
sliding door WT FSC
DP down pipe.
BAL
BLK MOS DS driveway slab.
FT CS FT join waterproof tanking BLK
ref. det. to inside of planter FC1 fibre cement cladding
MAIN LEVEL T.O.W R.L 27.535 MAIN LEVEL (no. ref. type).
FFL 27.535 sliding door track FFL 27.535 FG fascia gutter.
CS
pool window (wall) - refer pool engineer for rebate detail
PLANTER FT1 floor tile - (no refers to type).
1,500
1,500
POOL POOL PB PB NGL SF
void
GS garage slab.
EX. slab to remain MOS MOS MOS NGL BLK
ref. det. ref. det.
BLK
GARAGE hot water service.
2,400
HWS
waterproof membrane/
pool window (floor) - refer pool engineer for rebate detail PB
drainage & protected HR handrail, refer detail
termite barrier to BCA/AS
CELLAR
885
2,100
2,100
NGL AFW MOS MOS CS join epox CS CS epox join joinery item, by joiner
LOWER LEVEL 7 LOWER LEVEL
6
LPG LPG gas bottle.
FFL 24.950 5 STR FFL 24.950
EuroCave case storage join TF CS 4 NRG NRG board
BLK PB SF
3
2
R:0.17 BLK MOS mosaic pool tile
1
G:0.28
MR1 metal roof - (no refers to type).
waterproof membrane/
NE natural ground line.
SF SF NGL
drainage & protected
DU
ND termite barrier to BCA/AS
SECTION A PB plasterboard lining, ref. sched.
SA SCALE 1:100 @ A3
PF compliant pool fencing
3,000 PW parapet wall.
NOOSA COUNCIL PS patio slab.
A B C D E F G APPROVED PLAN PV photovoltaic cells.
132000.200173.1 REN polymer render
1,295 2,400 2,405 2,850 1,800 1,500 26 JUNE 2024 SBJ silicone butt jointed glass.
SP structural post, refer engineer.
AFW CS TF ASD PB MR CS 8M MR TIM CS REN AS REN DP FSC CS 8M
note - 8.0M height line
SF structural footing, refer engineer.
10.00° 10.00°
measured at line of STR1 stair (no. refers type)
section cut
T.O.W R.L 32.730 ROOF TERRACE note - 8.0M height line TIM timber cladding, ref. schedule
measured at line of
8M section cut TD timber deck.
5.00°
TF timber floor.
UPPER LEVEL
FFL 31.730 flashing TS timber screen, ref. detail
EX. stair to remain 'Villaboard' lining
EX
TIM VB
ST
AFW
BAL
WT1 wall tiles (no. ref. type)
AI
ref. det.
R
aluminium rafters and battens, refer detail D13 D18
PF
DA2 for Development Approval (DA2)
raking block wall - ref N.elevation
TIM
CS join TIM PB
EX. BAL issue issue / amendment
DINING LIFT BATHROOM 13.10.23 JH / MOD / SF
issue date drawn by
ASD
ref. det.
1,000
client
PB
Alum. batterns Ref. detail C & C Kelly
REN BLK
MAIN LEVEL project
FFL 27.535 CS Kelly Renovation
location
W01 W04 D08
1,500
AFW
D06 NGL 2 Arakoon Cres, Sunshine Beach
AL
MOS POOL PB PB AL EX.
join
EX.
Eurocave vent MOS LDY. FSC BLK FSC BLK
SECTIONS (A+B)
7 BATH ENS
2,285
VB REN
ex. block wall PB CELLAR 5
6
4 Aboda Lee Foster • director Scott Falconer • director
BLK W02 join
3 join
Design p - 0424 620 247
Group e - [email protected]
p - 0431 267 157
e - [email protected]
AFW 2
Eurocave R:0.172
1 the aboda design group trust Level 2 1794 David Low Way Coolum Beach,
LOWER LEVEL inoa50 7 G:0.25
waterproof membrane/
ABN 56 266 884 746 Q. 4573. PO box 2449 Noosa Heads Q 4567
2,100
t/a aboda design group • BSA License -150580097 • www.aboda.com.au
6
FFL 24.950 CS 5 drainage & protected
CELLAR PB 4 SF SF termite barrier to BCA/AS
• This drawing is to be read in conjunction with engineers drawings & reports • Construction
to comply with all relevant SAA & NCC Codes & standard Bldg By-law 1975 & as amended •
SF 3 Copyright for design & drawings remain the property of the authors • Verify all dimensions on
join
R:0.17
2 site prior to commencement of any works • These drawings are not to be used for scaling.
BLK 1
G:0.28
scale Scale as noted issue
SECTION B
drawing no.
SECTIONS (A+B) waterproof membrane/
WD.601 DA2
SF SF CS
CS
drainage & protected
termite barrier to BCA/AS SCALE 1:100 @ A3
SCALE 1:100 @ A3
Document Set ID: 22655219
Version: 1, Version Date: 08/11/2023
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.