Original source · versioned page text
Appendix Q - Planning Scheme Code Responses
COMMUNITY USES CODE
Performance Criteria and Acceptable Solutions
Table 14-13 – For all Community Uses
COUNCIL USE
SPECIFIC OUTCOMES PROBABLE SOLUTIONS SOLUTIONS* COMMENTS
ONLY
14.30 Effects of use
Electricity supply infrastructure ✓ Complies with O1
O1 The development does not adversely S1.1 No solution provided. The development will not adversely affect the existing
impact on existing or future electricity or future electricity supply infrastructure.
supply infrastructure; AND
O2 All uses and works maintain an S2.1 Development for uses adjacent to or ✓ Complies with O2
adequate safe distance from electrical within 50m of an existing electricity Buildings are located a significant distance from any
infrastructure including substations, substation incorporates noise attenuation electrical infrastructure.
overhead powerlines, power poles and measures to mitigate noise impacts;
transformers. AND
S2.2 Buildings and structures (including
swimming pools, sheds, tennis courts and
outbuildings) are not constructed under
overhead electricity transmission lines, or
within electricity easements;
AND
S2.3 A minimum separation distance is
maintained from the electricity
transmission line to the closest boundary
of habitable buildings and child activity
areas, as follows—
(a) 20m for transmission lines up to
132kV;
(b) 30m for transmission lines between
133Kv and 275kV; and
(c) 40m for transmission lines greater
than 275kV.
1 Solution: ✓ = Acceptable Solution Appendix O
A/S = Alternative Solution Cooroy Care Farm
N/A = Not applicable to this proposal
521 Elm Street and 10-22 Rose Gum Road, Black Mountain Commenced 3 February 2006 – Updated 3 March 2008 Page 1