Appendix Q - Planning Scheme Code Responses
COMMUNITY USES CODE
Performance Criteria and Acceptable Solutions
COUNCIL USE
SPECIFIC OUTCOMES PROBABLE SOLUTIONS SOLUTIONS* COMMENTS
ONLY
O8 Development does not include spill S8.1 No solution provided.
light which gives rise to annoyance,
discomfort, distraction or a reduction in
the ability to see essential information.
Table 14.31 – Built Form
Safety and security A/S Complies with O9
O9 All property boundaries are clearly S9.1 Boundaries identified by such means While intended to be integrated with the residential
identifiable and public and private spaces as: care facility, the community uses are distinguishable
are clearly defined. (a) fencing; from the residential care facility through appropriate
(b) changes in surface materials or design measures.
levels;
(c) landscape treatments.
O10 All premises and access routes are S10.1 All premises are identified by the ✓ Complies with S10.1
clearly identifiable to all persons, provision of the street number in a The premises will be identified by provision of street
particularly emergency services prominent location, preferably near the numbers at the entrance to the facility.
personnel. site entry, (ie. On the kerb or letterbox or
by signage on the building or site).
O11 All building entries are designed to S11.1 The number of entrances and exits ✓ Complies with S11.1
be obvious and easily identifiable. are limited and main building The site has primary and secondary entrances, which
entrances/exits located at the front of the will be signed to be clearly visible from the street. It will
site are in view of the street. Where this is be easy to navigate to the community uses from the
not possible, due to site or existing site’s entrance. Having the buildings clearly visible from
building constraints, a well defined path is the street would be inappropriate given the size of the
provided to the entrance/exit; and site and its rural zoning.
S11.2 All entrances/exits to buildings are ✓ Complies with S11.2
lit and signed and signage includes hours Community buildings will be appropriately lit and
of operation; and signed.
S11.3 Entrances/exits are located to ✓ Complies with S11.3
provide a direct link to driveways and The chapel and community hall are appropriately
carparking areas; and located on the internal road, and provide pedestrian
links to a shared carpark of the facility.
S11.4 Recessed doorways are avoided ✓ Complies with S11.4
where the recess is of sufficient size to Recessed doorways are not proposed.
conceal a person. Where recessed
doorways are unavoidable, measures are
used to enhance safety as follows—
(a) good lighting is installed;
1 Solution: ✓ = Acceptable Solution Appendix O
A/S = Alternative Solution Cooroy Care Farm
N/A = Not applicable to this proposal
521 Elm Street and 10-22 Rose Gum Road, Black Mountain Commenced 3 February 2006 – Updated 3 March 2008 Page 3