Council archive · source document
00158E47.001
Plans and drawings: the text below has words only, no drawings.
Text sections not matched to the original PDF pages. See original document to check page numbers.
‘ge ee oe
a a CT
NCOSA SHTRE COUNCT
rn 2 eee 18500 we eee we ee eee ee eee 4 "HO APPROVED
eee —— —— —- tr ee ee er Lt, es [so |
00
500
6380 1870 3680 35D SIGS ATURE M ocprewenenaunbemennne®
240 a 70 70 240 PATI Ze} 2_fed
to 4200 920 | 800 4410 R20 jp 2900
FLOOR AREA CALCULATIONS
Living Area 258.00 sqm
Patio Area 17.68 sqm
-————. Porch Area 5.82 sqm
GD1 ee a ree down Total Floor Area 281.50 sqm
——
inp ‘ Hiover oe ey vt W2 [____: $7 MOKE DETECTOR NOTE (SD)
MB | ee -Masenry retwalls tp W3 Provide new hardwired smoke detectors with approved
battery backup system in accordance with BCA reqs
Pl FC coiling nines lo | porch 0°] fngineer reqs v1 hy POWDER ROOM VENTILATION NOTE
rch ared = 3110 1870 | BEDZ 7 Provide approved light switch activated mechanical vent
system to powder room area in accordance with BCA
BLO x3X0
GARAGE” SL ) BED requirements, All vent systems to be ducted thru the roof
space to the outside air in accordance with Manufacturer
. tf OY 5110 x5900 R D1 je HY 31690 en , 3500« 3500 Specifications
PD |S), KITCHEN & LAUNDRY AREA NOTE
SP entry robe L1 All new kitchen and laundry area designs and layouts by
800x BO baxed cenin 2210wde ey TN 820 areas “| eas others in accordance with Owners requirements & selections
coffenng b lounge ar The layouts shown are to be used as @ guide only and may
=,@ der robe be adjusted t suit on site conditions & Owners requirements
t! BOx27210 ~ =-5- ROOF SUPPORT FRAMING LEGEND
! 1 82cs wap vo C) ~ LO», _b Ho 280x65 RH Tasbeam garage door support head
es 09065 reces: Lo 2D 2cutslo BC = e800 H3 240x63 LVL Hyspan roof support head
150x63 LVL Hyspan roof support head
(100 deep BATH H4 240x65 18C Tasbeam roof support head
| ™~ oT DY TAD ces garea 4p 1 ™ 220x350 HS 360x85 RH Tasbeam patio plate
3000 x36) 99 (™ f-4-4- WINDOW & DOOR SCHEDULE (Aluminium Framed}
2610 Mo [E ath i EE W3 3/450x450 clear fixed glass panels
"a W20TV, hall WIR T7040 W2 1200x2100 dear glass sliding window
1200x2400 clear glass sliding window {xoox)
aR ay £3 ~ LOUNGE 3 % H4 wer W4 900x1800 obscure glass sliding window
= 1800%2610 we26 | LON ©] WS 600x1200 obscure glass sliding window
a “etree Ei linen’. 4410x« 528Q | x te] W6 1200x2400 clear glass sliding window (xoox)
iT W7 2100x1200 clear fixed glass panel
0~ qT) W8 1500x1500 dear glass sliding window
100 i Re 700 7 mw % -_ ty 820 ; wl ENS: WS 1500x1500 clear glass sliding window
landing I WQ [oatie-| ret |* , 1a wi0 1800x900 clear glass double hung window
V 2510x202 Wit 400x1 600 glass bricks pane! @ kit bench top ht
qj N helves over + Wi2 1200x1800 clear glass sliding window
ve £2 a KTTCHEN S W13 ersu “| W13 800x1800 sq sat & timmed opening (future shutters)
ti] $01 2100x2700 clear glass sliding door
Sh re Hover she} baal OL SD3 2100x1500 clear glass sliding door
5 a xf oe 1202 cut slot %20+920 Pr $d2 2100x1500 dear glass sliding door
GD1 2100x4800 colorbond finish remote opening
panelift garage door
sk DINING E01 2040x1100 solid cove feature entry door and
iA LZ MASTER BED Clear fixed glass sidelight panets (2 off)
li-< 400 6460 44,90 380 x 20 | 2h ENSUITE WC AREA VENTILATION NOTE
iS} Provide approved light switch activated mechanical vent
| | FAM(LY XS FDI | system to ensuite we area in accordance with BCA reqs.
{
t Love «5090 ie = 901: al ? All vent systems to be ducted thru the roof space to the
outside air in accordance with Manufacturer specifications
=| / FC ceiling Inims ral “PATIO (hm -—— om a < GENERAL PLANS NOTE
nel
W6
20 :! / 5000 ‘painara 3070 «60 HSover cS tH ame leore Re) o| All written dimensions to take precedence over scale
The Designer accepts no responsibility and/or liability for
8 til |] any scaling of the plans as written dimensions always take
Si precedence. The Builder is to chack and verify afl dimensions,
My
—_a- levels, heights & pitches shown on these plans prior to the
ro W WS Start of any works and/or the ordering of any materials and/or
“i a labour. Any adjustments required must be approved by the
240 R 70 10 10 70 240 Designer in writing prior to the start of any works and/or the
ordering of any materials and/or labour.
1700 IL 1340 i $20 920 800 440 920 | 920 1 920 2020
I
54280 1000 4085 — : 3935 50
ft ££ CONLIN PBN A tt nk KFSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
00158E47.001.pdfRelated documentPublic source context ↗
07/1047 - Approved Plans MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 331 KB (small file)
- File type
No other editions are linked here.