DRAWING SIZE — AS

GENERAL :

1. DO NOT SCALE FROM THIS DRAWING.

2. ALL DIMENSIONS IN MILLIMETERS

3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.

4. ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND THE ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE ENGINEER
IMMEDIATELY.

5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.

6. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE SPECIFICATIONS AND REQUIREMENTS OF SCG CONSULTING
ENGINEERS SITE INVESTIGATION & FOOTING REPORT. (NO.29136(S))

7. PROTECTION AGAINST SUB-TERRAINIAN TERMITES IS TO BE IN ACCORDANCE WITH THE ARCHITECTS DETAILS.

8 ALL EXCAVATIONS ARE TO REMAIN DRY AND FREE OF ALL LOOSE MATERIAL PRIOR TO THE PLACEMENT OF CONCRETE.

9. WHERE COMPACTED FILL IS NOTED ON THIS AND ASSOCIATED PLANS, COMPACTION TO ACHIEVE 98% MINIMUM DENSITY RATIO.
TO BE ACHIEVED FOR COHESIVE (CLAY) SOILS AND 65% MINIMUM DENSITY INDEX FOR COHESIONLESS (SANDY) SOILS. IN
ACCORDANCE WITH AS3798-2007.

10. UNLESS NOTED OTHERWISE A MINIMUM BEARING CAPACITY OF 100kPA SHOULD BE ACHIEVED WITHIN COMPLETED FILLING.
COMPACTION AND BEARING CAPACITY TEST RESULTS MUST BE PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL
PRIOR TO WORKS PROCEEDING.

11. CHEMSET OR EPOXY BOLTING TO CONCRETE OR BLOCK WORK MEMBERS NOMINATED ON THE ATTACHED PLANS ARE TO
UTILISE RAMSET CHEMSET INJECTION 800 SERIES OR EQUALLY APPROVED. ALL WORK TO BE IN STRICT ACCORDANCE WITH THE
MANUFACTURERS REQUIREMENTS.

12. THE BUILDER MUST PROTECT ALL EXISTING NEIGHBOURING STRUCTURES/BUILDINGS THROUGHOUT THE WORKS, PARTICULARLY
DURING EARTHWORKS. REFERENCE SHOULD BE MADE TO OUR CRITICAL DEPTH LINE DIAGRAM OR SEEK GUIDANCE DIRECTLY FROM
THIS OFFICE

13. THE BUILDER MUST HAVE A B.A APPROVAL FOR THE PROPOSED WORKS FROM EITHER A PRIVATE CERTIFIER OR LOCAL
COUNCIL BEFORE ANY SITE INSPECTION CAN BE CARRIED OUT.

14. ALL BUILDING MATERIALS USED MUST MEET THE MINIMUM NATIONAL CONSTRUCTION CODE REQUIREMENTS.

BRACING :

NEW DWELLING: ALL NEW STRUCTURES TO HAVE 50% OFF SPECIFIED BRACING TO BE INSTALLED PRIOR TO ROOF GOING ON.
EXISTING DWELLING: DURING CONSTRUCTION TEMPORARY PROPPING & BRACING TO BE INSTALLED TO SCG CONSULTING ENGINEERS
‘SATISFACTION.

CONCRETI
1, ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH AS3600 — CONCRETE STRUCTURES

2. ADDITIVES INCLUDING FLY ASH CAN ONLY BE ADDED TO THE CONCRETE UPON THE APPROVAL OF THE ENGINEER.

3. ALL CONCRETE SHALL BE NORMAL CLASS CONCRETE UNLESS NOTED OTHERWISE. CONCRETE GRADES, MAXIMUM SLUMPS AND
MAXIMUM AGGREGATE SIZE ARE AS FOLLOWS;

FOOTINGS — 20MPa, MAX SLUMP 100mm é& 20mm MAX. AGG. SIZE.

GROUND FLOOR SLABS 100-150THK. - 25MPa, MAX. SLUMP 80mm & 20mm MAX. AGG. SIZE.

BEAMS/COLUMNS/SUSPENDED SLABS - 40MPa, MAX. SLUMP, 80mm & 20mm MAX. AGG. SIZE.

BLOCKWORK GROUT — N20, MAX. SLUMP, 100mm & 10mm MAX. AGG. SIZE.

4. ALL CONCRETE MEMBERS GREATER THAN 100mm IN THICKNESS MUST BE MECHANICALLY VIBRATED.

5S. IN NO INSTANCE SHALL THE CONCRETE BE WETTED UP PRIOR TO OR DURING PLACEMENT.

6. SLAB CONCRETE SHALL BE CURED FOR A MINIMUM OF SEVEN (7) DAYS BY AN APPROVED METHOD. DETAILS AVAILABLE UPON
REQUEST.

7. FORMWORK STRIPPING AND BACK-PROPPING OF SUSPENDED FLOOR SLABS TO THE APPROVAL OF THE ENGINEER.

 

 

SCREW PIERS :

1, SCREW PIERS WHERE SPECIFIED ARE TO BE DESIGNED AND INSTALLED BY SPECIALIST CONTRACTOR TO ACHIEVE THE LOADS
NOMINATED ON THE ASSOCIATED PLANS (SHOWN UNFACTORED). THE SCREW PIER SPECIALIST MUST SATISFY THEMSELVES WITH
REGARD TO ANY GEOTECHNICAL REPORT/INFORMATION REQUIRED FOR THEIR DESIGN. WE RECOMMEND THE BUILDER REQUEST THE
PIER CONTRACTOR INSTALL A TEST SCREW PIER PRIOR TO COMMENCING WORKS TO ENSURE ALL PIERING COSTS ARE KNOWN
BEFORE COMMENCING WORKS.

REINFORCEMENT
1. THE FOLLOWING MARKS ARE USED TO IDENTIFY THE VARIOUS REINFORCING STEELS USED, GOVERNING STANDARD FOR USE
ALSO LISTED;
TM — TRENCH MESH, min 450MPa (AS1304)
F — MESH/FABRIC, MIN. 450MPa (AS1304)
N — DEFORMED BAR, MIN. SOOMPa (AS1302)
R — PLAIN BAR, MIN 250MPa (AS1302)
W - HARD DRAWN WIRE, MIN 450MPa (AS1303)
2. ALL REINFORCEMENT SHALL BE CHAIRED, TIED AND RESTRAINED IN THE CORRECT LOCATION TO ENSURE NO MOVEMENT
DURING CONCRETE PLACEMENT. SLAB MESH CHAIRS AT 800mm CTRS. MAX. IN BOTH DIRECTIONS.
3. MINIMUM COVER TO REINFORCEMENT IS AS FOLLOWS;
FOOTINGS & PIERS - 40mm ALL FACES
SLABS ON GROUND - 30mm TOP (INTERNAL SURFACES)
— 30mm BOTTOM (OVER POLY. DPM)
— 40mm (EXPOSED SURFACES).
SUSPENDED SLABS — 30mm (INTERNAL SURFACES).
— 40mm (EXPOSED SURFACES).
BEAMS & COLUMNS- 40mm (EXPOSED SURFACES).
— 30mm (INTERNAL SURFACES).
4. MINIMUM LAP LENGTHS ARE 225mm (ONE PANEL PLUS 25mm) FOR SLAB MESH, 500mm FOR TRENCH MESH AND 40 TIMES
THE BAR DIAMETER OR 500mm WHICHEVER GREATER FOR REINFORCING BARS.
‘5. ALL EXPOSED STARTER BAR ENDS TO BE FITTED WITH PROTECTIVE END CAPS UNTIL ENCASED IN CONCRETE

LOADING CRITERIA:
BALCONY'S = 3.0kPa

TIMBER :

1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS1720 AND AS1684.

2. ALL TIMBER FRAMING AND MINIMUM SIZES UNLESS INDICATED ON THESE DRAWINGS SHALL BE IN ACCORDANCE WITH N3
TIMBER FRAMING MANUAL.

3. ALL TIMBER UNLESS NOTED OTHERWISE SHALL BE SEASONED.

4, ALL TIMBER STORED ON SITE SHALL BE STACKED CLEAR OF THE GROUND AND SHALL BE PROTECTED FROM THE WEATHER.

5. ALL BOLTED CONNECTIONS SHALL HAVE 80mm MIN. END CLEARANCE AND BE FITTED WITH GALVANIZED MILD STEEL WASHERS.
6. TEMPORARY BRACING AND SUPPORT IS TO BE PROVIDED THROUGHOUT THE CONSTRUCTION PERIOD UNTIL SUCH STAGE THAT
‘ALL MEMBERS ARE INSTALLED AND CONNECTED IN ACCORDANCE WITH DETAILS PROVIDED.

7. ALL TIMBER SHALL BE APPROPRIATELY PROTECTED FROM INSECT AND/OR MOISTURE ATTACK AT LEAST TO THE PROVISION OF
THE BUILDING CODE OF AUSTRALIA AND AS3660 — PROTECTION FROM SUB-TERRANEAN TERMITES.

8. PRE-FABRICATED ROOF TRUSSES ARE 10 BE DESIGNED AND MANUFACTURED BY A SPECIALIST CONTRACTOR. TRUSSES TO BE
BRACED IN ACCORDANCE WITH THE MANUFACTURERS REQUIREMENTS.

9. FLOOR JOISTS EXCEEDING 150mm IN DEPTH SHALL HAVE SOLID BLOCKING ALONG THE LINE OF ALL SUPPORTS AND AT MID
SPAN FOR ALL SPANS EXCEEDING 3.0m AND AT 1/3 POINTS FOR SPANS EXCEEDING 4.2m.

10. ALL FRAMING ANCHORS, FIXING PLATES, NAILING PLATES, JOIST HANGERS TO BE GALVANISED MINIMUM OR STAINLESS STEEL
WHERE CONSTRUCTION WITHIN 2.0 km RADIUS OF OPEN COASTAL AREAS.

11, GANG-NAILED SPLICE PLATES NOT PERMITTED FOR EXTERIOR TIMBER BEAMS.

12. ALL DETAILING OF GLUE LAMINATED AND LVL ENGINEERED TIMBER PRODUCTS SHALL BE IN STRICT ACCORDANCE WITH THE
MANUFACTURERS RECOMMENDATIONS.

‘STEELWORK :

1. ALL WORKMANSHIP SHALL BE IN ACCORDANCE WITH AS4100 WITH ALL MEMBERS AND SECTIONS BEING NEW AND FREE OF
RUST AND DAMAGE. ANY VARIATION TO THIS MUST BE CONFIRMED IN WRITING BY THE ENGINEER PRIOR TO ANY WORK
COMMENCING.

2. ALL STEELWORK UNLESS NOTED OTHERWISE SHALL CLEANED OF RUST AND MILL SCALE AND COATED WITH ONE COAT OF
ROZP.

3. EXPOSED STEELWORK INCLUDING BOLTS SHOULD BE HOT DIPPED GALVANIZED IN ACCORDANCE WITH AS4680 AS APPLICABLE.
4, ALL BOLTS SHALL BE IN ACCORDANCE WITH ASI111. UNLESS NOTED OTHERWISE ALL BOLTS SHALL BE GRADE 4.6 (S-SNUG
TIGHT) GALVANIZED. TEMPORARY BRACING AND SUPPORT SHALL BE PROVIDED UNTIL ALL BOLTS ARE INSTALLED AND TENSIONED.
5. ALL SHS, RHS AND CHS SECTIONS TO BE OF MINIMUM STRENGTH GRADE C350 IN ACCORDANCE WITH AS1163. ALL
UB/UC/PFC/EA/UEA SECTION 10 BE GRADE 300PLUS IN ACCORDANCE WITH AS3679

6. ALL WELDING SHALL BE CARRIED OUT BY A SPECIALIST TRADESMEN IN WORKSHOP CONDITIONS IN ACCORDANCE WITH AS2717.
ON-SITE WELDING IS ONLY PERMITTED FOLLOWING PRIOR APPROVAL FROM THE ENGINEER. UNLESS NOTED OTHERWISE ALL WELDS
‘ARE TO BE 5.0mm CONTINUOUS FILLET WELDS (C.F.W.).

7. THE ENGINEER IS TO BE PROVIDED WITH STEELWORK SHOP DRAWINGS FOR REVIEW AND COMMENT PRIOR TO FABRICATION.
REINFORCED BLOCKWORK :

1, ALL MATERIALS AND WORKMANSHIP TO BE IN ACCORDANCE WITH AS3700 2001.

2. MINIMUM MASONRY STRENGTH F'UC=15Mpa

3. MORTAR MIX 1: 1/2 : 5 (CEMENT:LIME: SAND)

4. ALL CORES TO BE CLEANED AND FREE OF ALL MORTAR FINS PRIOR TO GROUTING VIA CLEAN-OUT BLOCKS AT THE BASE OF
THE WALL.

5. MINIMUM GROUT STRENGTH f'c=20MPa (300kg/m3 MIN. CEMENT) WITH A MAXIMUM AGGREGATE SIZE OF 10mm. COMPACT
GROUT DOWN FULL DEPTH OF CORE WITH PLAIN ROD OR SIMILAR.

7. MINMUM COVER TO REINFORCING is 20mm FROM INSIDE FACE OF BLOCK. BARS TO BE ARRANGED AS SHOWN ON ASSOCIATED
DETAILS.

8. WALLS TO BE WATERPROOFED WHERE INDICATED ON THE DRAWINGS. WATERPROOF MEMBRANES INSTALLED IN STRICT
ACCORDANCE WITH THE MANUFACTURES REQUIREMENTS.

9. UNLESS NOTED OTHERWISE ALL WALL VERTICAL STARTER BARS ARE TO BE CAST INTO THE SUPPORTING FOOTING OR FLOOR
SLAB UNDER AS APPLICABLE

10. ALL MASONRY WALLS DURING CONSTRUCTION TO BE TEMPORARY BRACED OR OTHERWISE STABILISED AS NECESSARY TO
RESIST WIND LOADS OR LATERAL FORCES, IN ACCORDANCE WITH LOCAL AUTHORITIES WORK PLACE HEALTH AND SAFETY GUIDE
UNES.

ABBREVIATIONS USED.

WIND RATING = N3 (W41N) (Cont) CONTINUOUS SPANS NB PLEASE. NOTE

CTRS CENTRES 0 ALN DRIED
V&H VERTICAL & HORIZONTAL GL BELOW GROUND LEVEL
Tas Owe IN UN.O. UNLESS NOTED OTHERWISE
t piel THK THICK
SMD STEEL 1/8 LOAD BEARING

; HOW HARDWOOD
(GALV.) HOT DIPPED GALVANISED
Sq SQUARE V.0.S VERIFY ON SITE

S/S STANLESS STEEL (Grade:316)

1906 16

om

POOL NOTES :

— Pool to be constructed in accordance with AS
2783 and council safety requirements.

— Concrete Strength Fc = 32MPa at 28 days
(effective cement content to be not less than 280kg
per m3) for pools within 1km of large expanses of
salt water such as the sea (but pool not to be
constructed in tidal splash zones of salt water).
Where pools are constructed more than 1km from
large expanses of salt water (such as the sea) the
concrete strength may be reduced to 25MPa.

— Admixtures to comply with AS1478

— Concrete slump 80mm.

— Concrete to be sprayed in a continuous operation
and cured for 7 days minimum. This involves keeping
the walls and floor surface moist in an approved
manner (ie. fog spray) Alternatively the surface can
be sprayed with confilm or equally approved additive.
— Rod concrete in walls to remove all air pockets
(only vibrate in tight corners).

— Do not use curing compounds which affect the
bonding of applied coatings.

— Reinforcement — All steel to be grade 250 S bars.
Reinforcement — minimum cover 70mm +5/—Omm
— Reinforcement laps 500mm for S bars.

— All reinforcement bars to be continuous around all
corners and curves and shall be lapped UN.O.
Minimum stripping and/ or backfiling time is 14
days.

— The final pool shape and layout should be
approved by the engineer prior to commencement of
works.

= All fences and gates surrounding pool area shall
be in accordance with AS1926.

— The pool excavation shall in no way undermine any
adjacent structures or services (Refer to critical line
diagram provided). The pool contractor/builder is
responsible for obtaining all relevant levels and
positions of adjacent structures prior to commencing
work.

 

 

 

 

 

 

Revision | Description Date

Issue: BRELIMINARY
C) ste

BEQERAKAKWONSTRUCTION
NOTES

Unit 1/11 Project Ave,
Noosa Heads

Ph (07) 5455 5604

-email:[email protected]
webs gineers.com

 

 

Title:

Project The Cove, Noosa
28 Park Road, Noosa Heads

 

Date: Aug 2019 | Drg No. 29136-fAD1.

 

 

 

 

 
Full text of the other 5 pages

Page 2

 

bdd-9€16z N60 | 6102 Bny ‘eed

 

Spe} BSOON ‘peoy Wed Bz
BSOON ‘8A0D AYL yoloig

ev © OOL:;;pwo 1

S ¥ ¢ z L 0

 

 

NW1d 100d ‘ent

 

"N'9€16Z NO GANIVLNOO S3LON
SHL HLIM NOLLONAPNOO NI GV3Y 38 LSAW
S1NW130 G3LVIOOSSY CNV ONIMVYC SIHL

 

 

  

woo’ ssa@uj6us-Bs mw: qam
woo sisoubuefos@uwpe pew

09S SS¥S (20) Ud
speoly escoNn
tony walold LL/L WU ws

 

AUYNINTTSYC  -anss

 

aed uoyduoseg | uolsinay

 

 

 

 

 

 

STIVI30 Wald M3YOS

—
ald MJYOS T3aLS

(Tawog
(Noor x 94N/1)
—

 

 

‘MEINONA OL GENss!
38 OL NOLVTIVISNI YO NOLVOLILY3) 0NVTTdNOO
NWOSZ (Z-dS)

NYSLL (1=dS)

Ny001-(dS)

SMOTIOS S¥ 3Y¥ Suid

TWNGIAIGNI YOJ SOVOT ONDROM CEYOLOVINN WNHININ

“SXYOM ONIIYd OL YOldd
"MlO¥d¥9 YO4 Hid30 WYLINOD OL SYSld 1S3L TIVISNI
OL YOLOVALNOD JHL LWHL GJONSNNODSY SI LI-

 

“ONIOVdS Ydld

WAWININ SHL NO SSIAQV OL SI SaYMLOV4ANVA JHL
NV1d NI

NMOHS JUHA G31VOO1 38 Ol JYV SYald —
“NOLLWTIVLSNI

OL UOld NOISZO MJIAZY OL YIANIONS ‘NIYNLOVINNVA
ASIIVi04dS SHI A GANOISSA 38 OL M3YOS THALS —

SINGSHOS Ysld MIYOS

 

STWL90 YO4 VZOd 940 A494
O30 C3NVYs YGNIL tod
SALVOIONI V34¥ O3HOLVH

 

 

                         

SZL AB
(9) @ (8) 135440
(0) os2-zis

% (8) 0S2-ZIN

“AVIS G3ONIdSNS \
UONN HONTUL YaLVMAYOLS: nN
40 NOILVO01 uymouscs 7 S
SALVOIGNI S4NIT G3HSW:

 

INANSOV1d YO4 NOWLVLON Uva

ASML OY]
saya (Vv)

  

QUIHL OV
saya (9)

ASW GIV1

wuigzt 8 (9) ® (8) save (0)
24
 (v) 138440

"S13 YOd 2'1'S ONC
UadaY WIE TIHS 100d (a)osr * (MoS ~10—-@d

“QVO1 ONIYNOM WNNININ 404 FINGIHOS:
Uald MANOS YI ‘Yad MIYOS THUS * (1-as)

QNJOF1

STNW130 404
70d 94O Y34FY INIWIOYOANITY
TIVM TTSHS 100d 404

ev — aZIS ONIMVYC

 

 

Page 3

 

 

DRAWING SIZE — AS

 

4 — N12 HORIZONTAL

 

                

 

 

 
 

 

 

 

 

 

 

 

sg BARS, CONTINUOUS,
= 500 EQUALLY SPACED IN EDGE
THICKENING.
WATER LINE. ae —
250 NIN. YC
x POOL WALL
2 $12 @ 125 HoRZ
3 FULL PERIMETER I"
Zz 4
3 POOL WALL
s $12 @ 250 VERT
2 INNER FACE ‘ Mi
N16-250 (A) & (0) ; FACE
N12-250 (8) & oer (A) & (0) ke
st2-250 (C) Rag
OFFSET (8) & (C) Oy
BY 125 Y
G, at
we
FALL, FALL a,
3 : = eran
== ss,
gn \ek
2 sap 3/L11TM BOTTOM

 

 

 

 

| _____ SO0MM X SOOMM PIT FILLED WITH

10MM TO 20MM CRUSHED ROCK
FINES) FILTER MATERIAL.
WRAP IN GEOTEXTILE MEMBRANE.

HYDROSTATIC PRESSURE RELIEF
VALVE TO CURRENT AUSTRALIAN
STANDARD. SEALED AND BONDED TO
POOL FLOOR IN ACCORDANCE WITH
THE MAUFACTURERS SPECIFICATION.

250

200,

 

 

N12 TIES 250 CTRS 300
COGGED ENDS lA

450

 

  

 

KET MPICAL SECTION

(A. PB-01_~ POOL BASE BEAM

 

NDS UP 400mm INTO
POOL WALL

SCREW PIERS AS NOTED ON
PLAN, DESIGN BY SPECIALIST
CONTRACTOR.

 

 

SCREW PIERS AS NOTED ON
PLAN, DESIGN BY SPECIALIST
(NO CONTRACTOR.

100mm THICK COMPACTED 10MM

TO 20MM CLEAN CRUSHED ROCK
FILTER MEDIA.

TYPICAL SECTION ~ POOL

250 MIN.

N12 @ 200. CENTRES,
PLACED CENTRE.

 

 

200 MIN.

{SKIMMER BOX IN
ACCORDANCE WITH
AS1926

 

 

 

LOCATE SKIMMER BOX
SO FLAP FACES
PREVAILING WIND.

 

 

500

 

 

 

 

 

 

 

 

t— N12 @ 200MM CENTRES
AROUND SKIMMER BOX.
PLACED CENTRE.

 

 

   

“ TO FILTER
~~

SECTION
SKIMMER BOX DETAILS

 

 

 

 

THIS DRAWING AND ASSOCIATED DETAILS
MUST BE READ IN CONJUNCTION WITH THE
NOTES CONTAINED ON 29136-N.

 

 

General Notes :

— Pool to be constructed in accordance with AS 2783 and
council safety requirements.

— Concrete Strength Fc = 32MPa at 28 days (effective
cement content to be not less thon 280kq per m3) for
pools within 1km of large expanses of salt water such os
the sea (but pool not to be constructed in tidal splash
zones of salt water). Where pools are constructed more than
tkm from large expanses of salt water (such as the seo)
the concrete strength may be reduced to 25MPa.

— Admixtures to comply with AS1478

= Concrete slump 80mm.

— Concrete to be sprayed in a continuous operation ond
cured for 7 days minimum. This involves keeping the walls
‘and floor surface moist in an approved manner (ie. fog
spray) Alternatively the surface can be sprayed with confim
‘or equally approved additive,

= Rod concrete in walls to remove all air pockets (only
vibrate in tight corners).

— Do not use curing compounds which affect the bonding of
‘pplied coatings.

— Reinforcement — Unless noted otherwise reinforcement to
be grade 250 S bars.

Reinforcement — minimum cover 70mm +5/—Omm

— Reinforcement laps 500mm for S bars.

— All reinforcement bars to be continuous around all corners
‘and curves and shall be lapped U
Minimum stripping and/ or backfiling time is 14 days.

— The final pool shape and layout should be approved by
the engineer prior to commencement of works.

— The reinforcement and associated metal components are
to be electrically bonded (isolated) by a registered Electrician
in accordance with current regulations & gu
— All fences ond gates surrounding pool area shall be in
accordance AS1926.

— The pool excavation shall in no way undermine any
adjacent structures or services (Refer to critical line diagram
provided). The pool contractor/builder is responsible for
obtaining all relevant levels and positions of adjacent
structures prior to commencing work.

 

 

 

  

 

 

 

 

 
 

 

 

 

 

 

 

Revision | Description Date

Issue: PRELIMINARY
C) ste

Title: POOL DETAILS

      

Unit 1/11 Project Ave,
Noosa Heads

Ph (07) 5455 5604
[email protected]

web:www.sog-engineers,com

 

Project The Cove, Noosa
28 Park Road, Noosa Heads

 

Date: Aug 2019 | Drg No. 29136-PD1.2

 

 

 

 

 

Page 4

 

DRAWING SIZE — AS

HATCHED AREA INDICATES
PROPOSED POOL REFER DRG PO1.1
FOR DETAILS

POOL DECK PLAN
LEGEND

XN
N
N

          

 

Pr
PAs) 88.9 x 4.8 CHS GALV STEEL POST SLEEVED

 

 

© OVER SCREW PIER POSTS, REFER SCREW FLOOR FRAMING SCHEDULE
PIER SCHEDULE FOR MINIMUM WORKING MARK SIZE /GRADE
LOAD. REFER DRG PD2.2 FOR DETAILS WI | 250 x 50 (FI7) HOW WOSTS @ 450 CRS
FBI | 310UB46 STEEL BEARER GALV
8 THK UPSTAND CLEAT, 2/MI6 BOLTS TO DECK ran | 300PEC STEEL BEARER GALV

(80) o(STS WHICH FALLS ON MID-SPAN OF STEEL
BEAMS, 80mm Min. END CLEARANCE ON ALL Wet | 125 x 75 (F17) HOWD WALL PLATE
TIMBER HOLES. REFER ORG PD2.2 FOR DETAILS DU DOUBLE JOIST, M12-600 STAGGERED

* INDICATES MEMBER WITHIN FLOOR DEPTH

 

 

 

 

\) tom GRADE 316 STAINLESS STELL. BEND
CLEAT, 2/M16 BOLTS EACH END, 80mm Min
ENO CLEARANCE ON ALL TIMBER HOLES. REFER

  

ORG PD2.2 FOR DETAILS should
ns top edges
ze 16 DIAM GALV DIAGONAL ROD BRACING SETS of deck iss deck bearers to og mine the ingress of
moisture.
WITH TURNBUCKLE ADJUSTERS, REFER DRG = (CONT.) Indicates Continuous over 2 spans or more. Spans to
PD2.2 FOR DETAILS. be ne more ‘or less than 20% greater than adjacent span for
continuity.

 

DASHED LINES INDICATES

LOCATION OF STORMWATER
TRENCH UNDER SUSPENDED SLAB.
(1/n16 X 400(L)
DOWEL.)
STEEL SCREW PIER
=

SCREW PIER DETAILS

ALL DJ TRIMMERS FIXED TO STEEL
BEAMS UNDER WITH 8 THK
UPSTAND CLEAT AND 2/M16
BOLTS

         

 

THIS DRAWING AND ASSOCIATED DETAILS
MUST BE READ IN CONJUNCTION WITH THE
NOTES CONTAINED ON 29136-N.

 

 

 

fann——t___?}—1_fm1:100 © A3

SCREW PIER SCHEDULE

— STEEL SCREW TO BE DESIGNED BY THE SPECIALIST
WANUFACTURER, ENGINEER TO REVIEW DESIGN PRIOR TO
INSTALLATION.

= PIERS ARE TO BE LOCATED WHERE SHOWN

IN PLAN

THE MANUFACTURER IS TO ADVISE ON THE MINIMUM
PIER SPACING.

IT IS RECOMMENDED THAT THE CONTRACTOR 10

INSTALL TEST PIERS TO CONFIRM DEPTH FOR CAPACITY,
PRIOR TO PRICING WORKS.

IMUM UNFACTORED WORKING LOADS FOR INDIVIDUAL
PIERS ARE AS FOLLOWS
(SP)-100KN
(SP—1) 150KN
(SP-2) 200KN
COMPLIANCE. CERTIFICATION FOR INSTALLATION TO BE
ISSUED TO ENGINEER.

 

ALL FRAMING ANCHORS BOLTS AND
ASSOCIATED CONNECTIONS FOR THE
TIMBER DECK 10 BE GRADE 316
STAINLESS STEEL

ALL STEEL BEAMS SUPPORT POSTS AND
ASSOCIATED CONNECTIONS TO BE HOT
DIPPED GALVANISED

 

 

 

Revision | Description Date

 

 

              

Issue: PRELIMINARY

GaN Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604

[email protected]

 

Title: POOL DECKING PLAN

   

Project The Cove, Noosa
28 Park Road, Noosa Heads

 

 

Date: Aug 2019 | Drg No. 29136-PD2.1

 

 

 

Page 5

 

DRAWING SIZE — AS

80 MIN. END
CLEARANCE ON
HOLES

50 MIN. SIDE
CLEARANCE ON

   
  
 

POOL SHELL

FLOOR BEAM geNnD. i

AND BOLTS AS
SPECIFIED.

= (B) ~ TIMBER BEAM CLEAT
TYPICAL DETAIL

NOTCH JOISTS OVER
PLATES AND PROVIDE
FRAMING ANCHOR

   

 

100x50 HDWD PLATE,
Mi2-600 CTRS TO DJ, MIN
65 EDGE CLEARANCE ON

BOLT HOLES

JOIST TO DOUBLE JOISTS
TYPICAL DETAIL

12 THK PFC END
PLATES 2/M20-8.8

Y 300PFc (GALY.)

 

 

 

 

 

 

 

 

 

 

7
| Ni THK POST END

1
I | PLATE 2/M20-8.8
Py TO EACH PFC

¢ - \ PFC-PFC & POST CONNECTION
TYPICAL DETAIL

 

NOTCH JOISTS OVER WP1

  

ANCHOR

\ WP1, M12-600
CTRS TO POOL

SHELL
é - \ JOIST TO WALL PLATE
TYPICAL DETAIL

12 THK PFC END
PLATES 2/M20-8.8
'

¥

 

AND PROVIDE FRAMING

8 M.S. PURLIN CLEAT,
2/M12 BOLTS.

_oe_DECK Joist
tet

UB OR PFC
ROOF BEAM

= (BC) ~ TIMBER BEAM CLEAT
TYPICAL DETAIL

 

 

 

 

 

 

 

 

300PFC (GALV.)

 

 

 

 

 

qr Tr
| Il
mld

PFC-PFC & POST CONNECTION
TYPICAL DETAIL

 

12 THK PFC/UB END

 

T

12 THK POST END
PLATE 2/M20-8.8
TO EACH PFC

916 CROSS BRACES
WITH TURN-BUCKLES,
10mm TAGS

5.0 CF.W.

1/M20 BOLT FOR 916

PLATES mes
3o0prc (GaLv.) Y  310uB (GALV))

 

 

 

 

 

 

rT
I I
OR

 

Ny THK POST END

PLATE 2/M20-8.8
TO PFC 2/M20-8.8
TO UB

PFC-UB & POST CONNECTION

 

TYPICAL DETAIL

 

PI

    

DECK JOIST

 

   
   
  

DECK JOIST

75x50 HOWD 2/FRAMING
NAILING PLATE ANCHORS EACH
M12-900 MEMBER.

JOIST TO BEAM
we, TYPICAL DETAIL

75x50 HOW 2/FRAMING
NAILING PLATE ANCHORS EACH
M12-900 J MEMBER.

‘STEEL,

BEAM

 

 

 

END PLATE AND
BOLTS AS DETAILED

(1) STEEL
POST

(P1) POST TO SLEEVE
OVER SCREW PIER,

2/M16-8.8 BOLTS

i —— STEEL SCREW PIER, BY
SPECIALIST CONTRACTOR

~ STEEL POST CONNECTIONS

TYPICAL DETAIL

“| Date: Aug 2019

THIS DRAWING AND ASSOCIATED DETAILS

MUST BE READ IN CONJUNCTION WITH THE
NOTES CONTAINED ON 29136-N.

 

 

 

Revision
Issue:

 

 

 

Description Date

PRELIMINARY

C) sce

Title: FRAMING DETAILS

Unit 1/11 Project Ave,
Noosa Heads

Ph (07) 5455 5604
[email protected]

web:www.sog-engineers,com

Project The Cove, Noosa
28 Park Road, Noosa Heads

Drg No. 29136 -PD2|2 .

 

 

Page 6

 

 

 

 

 

NOTE,

THE TITLE BOUNDARIES AS SHOWN HEREON WERE NOT MARKED AT THE TIME
OF SURVEY AND HAVE BEEN DETERMINED BY PLAN DIMENSIONS ONLY AND
NOT BY FIELD SURVEY. AS. SUCH BOUNDARY DIMENSIONS COULD BE OUT OF
DATE. AND INCORRECT. IF BOUNDARY DIMENSIONS NEED TO BE VERIFIED, THE
SERVICES OF A CONSULTING CADASTRAL SURVEYOR SHOULD BE ENGAGED.
ALL MSIBLE SERVICES HAVE BEEN LOCATED, HOWEVER PRIOR TO ANY
DENOLITION, EXCAVATION OR CONSTRUCTION ON THE SITE, THE RELEVANT
AUTHORITY ‘SHOULD BE CONTACTED FOR POSSIBLE LOCATION OF FURTHER
UNDERGROUND SERVICES AND DETAILED LOCATIONS OF ALL SERVICES.

NOOSA COOLOOLA LAND SURVEYS PTY LTD ACCEPTS NO RESPONSIBILTY FOR
DAMAGE TO SERVICES SHOWN OR NOT SHOWN ON THIS PLAN

ATLE SEARCH HAS NOT BEEN CARRIED QUT TO CHECK FOR THE ENSTANCE|
(OF EASEMENTS OR TO VERIFY IF THE PROPERTY DESCRIPTION SHOWN IS
‘CORRECT.

ADJOINING DESCRIPTIONS HAVE NOT BEEN SHOWN.

BUP5386

 

 

 

Noosa Cooloola Land Surveys Pty Ltd
Consulting Land Surveyors
ACN 613974486

yy P.O. Box 1684, Noosa Heads, QLD. 4567

Lau Greg Martoo
782360 0409 632830

  

 

NOTE

LEVEL DATUM — PSM97280 RL13.341 AHD D
CONTOUR INTERVAL — 0.25m

 

Detail Survey of Part
of Common Property

on BUP104971

28 Park Road

Noosa Heads

 

PARISH
COUNTY

Locality Noosa Heads

ORIGINAL

 

 

SCALE 1: 200/41
DATE 04/09/2019
DRAWN PS

 

 

DRAWING 19363Det

 

 

 

 

 

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Engineering and survey plans.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.