Negotiated Decision Notice - 010.2007.00000256.001 [As Published] · 132007.256

of 20

Text shows just the words. Original shows the document exactly as it was published.

                                                                                      2007/256




       Existing Development                                Approved Development
                                                           Approved Use Class /       Approved
       Existing Use Class / Use     Existing Quantity
                                                           Use                        Quantity
       Industrial Business Type
                                          2
       2 - Production, alteration, 1,450 m use area
       repackaging and repairing
                                                                                                  2
       +                           +                       Retail Business Type 6     5,740 m use
                                          2
       Retail Business Type 3      2,240 m use area        - Hardware Store           area
       - Landscape and rural                               +                          +
                                                                                             2
       + Additional remaining credit for water             Retail Business Type 7     1,815 m use
       headworks given from balance of 2007/1626 Re:       - Garden Centre            area
       previous water & sewerage headworks
       contributions acquired from call in of bond
       applicable to Rezoning Deed, R 228
2.   The applicant is informed that approval of this development application will trigger an
     Infrastructure Charge in accordance with the Coastal Major Road Network Infrastructure
     Charges Plan for the estimated amount of $716,439 and is subject to variations in the
     Consumer Price Index, All Groups Brisbane from MARCH 2009 until the date of payment. An
     Infrastructure Charge Notice will be issued in accordance with Chapter 5 of the Integrated
     Planning Act 1997.
3.   The applicant is informed that payment via credit card transaction will not be an acceptable
     method of payment for development contributions conditioned in this permit or for
     infrastructure charge notices issued separately.
4.   Digital detailed designs including drawings, calculations and specifications shall be submitted
     with any application for a Development Permit for Operational Works in respect of roadworks
     and stormwater drainage works. In this regard a DXF/DWG file on GDA94 zone 56 grid of the
     proposed cadastre layout is to be submitted in conjunction with any application for Operational
     Works. The design shall be in accordance with Council’s Planning Scheme Policy PSP05 –
     Engineering Design Standards – Roads, Drainage and Earthworks.
5.   To facilitate production of As Constructed drawings it is suggested that all design drawings are
     submitted in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the
     use of ADAC are available at www.adac.com.au).
6.   The applicant is advised that a Compliance Permit for all plumbing and drainage works within
     the boundaries of the development site shall be obtained from Council’s Plumbing Services
     Section prior to obtaining a Development Permit for Building Works.
7.   The applicant is advised that this development may require the provision of fire hydrants and a
     booster pump in accordance with the Building Code of Australia, and consultation may also be
     needed with Queensland Fire Services to ensure suitable fire fighting infrastructure is
     provided. To this end any necessary fire hydrants shall be clearly shown on the plans
     submitted for both Operational Works and Building Works approval and if a booster pump is
     deemed necessary, the plans shall indicate where the fire truck is to be accommodated in
     order to provide boosting to the water supply.
8.   Approval for the Underground Petroleum Storage System should be obtained under the
     Dangerous Goods Safety Management Act 2001 and the Environmental Protection Act 1994.
     The application for such approval should be lodged with Council’s Environmental Health
     Section and includes an assessment by a competent person of the site’s class pursuant to
     Council’s “Operators Compliance Guide for Petroleum Product Storage”.




                                                                                       14 of 20

Used in these records

About this file

File size
101 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Negotiated Decision Notice - 010.2007.00000256.001 [As Published].pdf · 101 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.