Log in to see the plans as drawn1.GENERAL NOTES AND SPECIFICATIONS
ASSUMED TERRAIN WIND CATEGORY - N3 - (W41-N) - REFER ENG SPECIFICATIONS AND VERIFY BEFORE BEGINNING CONSTRUCTION.
GENERAL - ALL WORK TO COMPLY WITH CURRENT NCC FOR CLASS 1 AND 10 BUILDINGS AND LOCAL COUNCIL REQUIREMENTS
BEFORE COMMENCING CONSTRUCTION ALL DIMENSIONS, EXISTING AND FINISHED LEVELS AND ALL SITE SURFACES ARE TO BE VERIFIED BY CONTRACTOR.
ARCHITECTURAL DRAWINGS AND SPECS TO BE READ IN CONJUNCTION WITH STRUCTURAL ENGINEERS DRAWINGS AND SPECS. IN EVENT OF AMBIGUITY CONTACT ARCHITECT PRIOR TO CONTINUING WITH WORK.
DIMENSIONS TAKE PREFERENCE OVER SCALE - DO NOT SCALE FROM DRAWINGS!
STORMWATER COLLECTION AND RETICULATION AND ON-SITE SEWERAGE TO BE AT THE APPROVAL OF LOCAL COUNCIL. EVIDENCE AND COPIES OF ALL REQUIRED APPROVALS TO BE SUPPLIED TO OWNER PRIOR CONSTRUCTION.ALL RELEVANT WARRANTIES INCLUD-
ING SIGNED FORM 16 DOCUMENTS TO BE PROVIDED TO OWNER IN COPY FORM AT COMPLETION OF CONSTRUCTION.
NO PLUMBING STACKS OR SERVICE SUPPLY LINES TO BE VISIBLE ON EXTERNAL FACE OF BUILDING.
PROVIDE TERMITE PROTECTION AND CERTIFICATES IN ACCORDANCE WITH NCC SECTION 3.1
STAIR, HANDRAILS AND BALUSTRADE CONSTRUCTION TO BE IN ACCORDANCE WITH NCC PART 3.9
WATERPROOFING TO WET AREAS IN ACCORDANCE WITH NCC PART 3.8
GLAZING TO BE IN ACCORDANCE WITH NCC PART 3.6
SMOKE ALARMS TO BE IN ACCORDANCE WITH NCC PART 3.7.2
2.ELEMENT SPECIFICATION
CODE DESCRIPTION PRODUCT SPEC & SIZE & FINISHES NOTES SUPPLIER & CONTACT REV
BLK BLOCKWORK
BLK-1 Rendered Blockwork 140 Series Core Filled Blockwork. Reinforced to Structural Engineers Spec
Finish: REN-1
Colour: TBC
CLG CEILING
CLG-1 Plasterboard 10mm thick ‘Gyprock’ or equivalent plasterboard sheeeng with flush set joins.. Refer to Architec-
tural Drawings for details.
Finish: PAINT
Colour: In accordance with Architects final colour scheme.
CLG-2 Fibre Cement Hardies 6mm fibre cement sheet
Finish: MaL Clear Finish water based zero VOC.
Fixing: Galv. clout nailed, buL jointed
CLA CLADDING
CLA-1 Fibre Cement SheeSng 6mm Fibre Cement sheeeng installed to manufactures specificaeon. Refer to Architectural Drawings for Extent.
Finish: Paint
Colour:TBC
CONC CONCRETE
CONC-1 Concrete Footpath Reinforced to Structural Engineers Spec
Finish: N/A