Skip to the record
The definitive source for everything Noosa Council.

Original source · versioned page text

Contour & Detail Survey

of 1

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

                     SW
SW




      TBM
     Screw in
      kerb
     RL 76.65
      AHD




                                 TRUNK
                      TREE                HEIGHT   SPAN
                               DIAMETER
                     NUMBER                 (m)     (m)
                                  (m)
                          1      0.6        12      8
                          2      0.4        10      4
                          3      0.4        10      5
                          4      0.5        10      4
                          5      0.3        10      4
                          6      0.5        10      4
                          7      0.6        6       5
                          8      0.3        6       3
                          9      0.4        9       4
                          10     0.3        9       4
                          11     0.4        9       4
                          12     0.4        9       4
                          13     0.4        10      5
                          14     0.3        10      3
                          15     0.3        10      3
                          16     0.3        9       3
                          17     0.3        10      3
                          18     0.3        10      3
                          19     0.3        10      3
                          20     0.3        9       3
                          21     0.5        8       4
                          22     0.5        8       4
                          23     0.3        9       3
                          24     0.4        10      4
                          25     0.5        10      4
                          26     0.4        10      5
                          27     0.6        12      7
                          28     0.4        8       3
                          29     0.3        7       3
                          30     0.3        10      4
                          31     0.4        8       3
                          32     0.4        8       3
                          33      4         8       4
                          34     0.6        7       6
                          35     0.3        8       2
                          36     0.4        10      4
                          37     0.5        8       4
                          38     0.4        10      4
                          39     0.5        10      4
                          40     0.4        8       3
                          41     0.4        8       3
                          42     0.5        8       5
                          43     0.3        8       3
                          44     0.4        9       4
                          45     0.4        9       4
                          46     0.4        9       4
                          47     0.4        9       4
                          48     0.4        10      4
                          49     0.4        10      4
                          50     0.4        10      4
                          51     0.4        10      4
                          52     0.4        10      4
                          53     0.5        7       4
                          54     0.4        9       4
                          55     0.7        7       4
                          56     0.3        10      4
                          57     0.9        14      8
                          58     0.4        10      4
                          59     0.4        10      4
                          60     0.5        10      4
                          61     0.4        10      4
                          62     0.4        10      6
                          63     0.7        12      8
                          64     0.4        8       4
                          65     0.4        12      8
                          66     0.5        12      7
                          67     0.7        14      8
                          68     0.4        10      6
                          69     0.5        12      7
                          70     0.4        5       3
                          71     0.4        12      6
                          72     0.3        10      4
                          73     0.4        7       5
                          74     0.5        6       5
                          75     0.4        6       6
                          76     1.2        16     10
                          77     0.4        9       4




                FH



                SW



                WM


[OCR of page images]
 

\

2 w

   

»

 

   
 
 

 

 

 

   

 

 

 

 

 

 

 

=e Te

 

  

 

 

 

 
 
 
 

 

 

 

  
  
 

wk
x

 

  
  

 

 

   

 

  
  
    

 

         
    
   
  

 

 

    

 

 

 

 

 

 

 

 

 

 

 

 

 

6 & ro e © _ _ | _ROAD CENTRELINE <
x — ~* — — oe oe <— ax
GULLY PIT
BLOCKED AND NN w
FULL OF WATER w
BASE RL:74-19 WE WL A ND
Ww WwW WwW Ww Ww Ww Ww a Ww
Ns EDGENOF BITUMEN * Tw
2 __ __CONCRETEL aes x
_ ‘s
/ ee "MANHOLE - UNABLE TO OPEN.
° ( xepawverT @ PIPE NOT SHOWN ON DBYD
w—* w W _ 2

WATER PIPE S PLOTTED FROM
DBYD & SURFACE FEATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

    

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= e
ot e* / oo? STEM Ss BACK OF UPRIGHT KERB f /
x - &
Screw in || - d ¢ “
alse 6s 7 : BD TELSTRA PLOTTED FROM DBYD & SURFACE
w Ww ts w w w w rio) / FEATURES
a” RRIGATI ola x ie CONCRETE q eo Pim, 6 4 e
PIT. Cc \ a3 DRIVEWAY | 3698 2 / 90°09 © © #
TTY : , ~ —
cy { ~rF i x—// 1s oe
o 5 ann 1 <——— //
@ Na a CHAIN: MESH \ FENCE
x TRUNK
UNKNOWN | TREE DIAMETER | HEIGHT | SPAN
CONDUIT NUMBER (m) (m) (m)
2
s 1 0.6 12 8
. 2 0.4 10 4
8 3 0.4 10 5
=
S 4 0.5 10 4
S
R 5 0.3 10 4
5 6 0.5 10 4
7 0.6 6 5
8 0.3 6 3
9 0.4 9 4
ast 10 0.3 9 4
11 0.4 9 4
12 0.4 9 4
13 0.4 10 5
14 0.3 10 3
15 0.3 10 3
& 16 0.3 9 3
17 0.3 10 3
18 0.3 10 3
19 0.3 10 3
20 0.3 3
Z 21 0.5 4
cP 22 0.5 4
BUP4542 5 =
< < 23 0.3 3
x 24 0.4 10 4
g 25 0.5 10 4
7 ne 26 0.4 10 5
=
g Fw 27 0.6 12 7
my J 28 0.4 8 3
oye g 29 0.3 7 3
oO 8 y
| 3 30 0.3 10 4
7 31 0.4 8 3
g 32 0.4 8 3
33 4 8 4
34 0.6 7 6
35 0.3 8 2
36 0.4 10 4
37 0.5 8 4
38 0.4 10 4
39 0.5 10 4
40 0.4 8 3
41 0.4 8 3
42 0.5 8 5
43 0.3 8 3
44 0.4 9 4
oo fe 45 0.4 9 4
\ Fy
\ g 46 0.4 9 4
Se 47 0.4 9 4
ss 48 0.4 10 4
Xx
5 49 0.4 10 4
an 50 0.4 10 4
* 51 0.4 10 4
52 0.4 10 4
53 0.5 7 4
54 0.4 4
55 0.7 4
56 0.3 10 4
57 0.9 14 8
58 0.4 10 4
59 0.4 10 4
g \ 60 0.5 10 4
| \
Sy | \ 61 0.4 10 4
XI | \
ss | \ 62 0.4 10 6
. | | 63 07 2 8
no | \ 64 0.4 8 4
ae ef \ | | e \ ones $ 65 0.4 12 8
| \ 2 73:33 “ \ 20"
— ne 66 0.5 12 7
A“ // Ls %e METAL Poo. Fence = 47925 ue ne 67 0.7 14 8
ar ans ® WIRE FENCE 0 4 s "
BLOCK WALL 68 0.4 10 6
49 69 0.5 12 7
5/ 50 RP8B8B934 70 0.4 5 3
52 71 0.4 12 6
RP88934 RP88934 RP88934
72 0.3 10 4
Legend 73 0.4 5
Top of bank yp yy pgp —
Toe of bank —.- 74 0.5 5
Slrmwarer, ——_D 75 04 6 6
Telstra
Electricity ——E 76 1.2 16 10
Under Ground uU/G 77 0.4 9 4
Water w
Fence //
w Electric Power Box
DISCLAIMER @ Power Pole
Boundaries shown hereon are plotted from Fie tonne
deed dimensions and were not reinstated at © = Sewerage Manhole
the time of survey @ Stormwater Manhole
. Q Telstra Pit
Only visible services have been located. By Water Meter
. . ~ Water Valve
Before commencement of any design and construction e Gully Trap
works, the location of these services must © Permanent Survey Mark
be verified on site by the relevant @ Temporary Bench Mark
authorities. A Traverse Station
i O° Peg - Original
The shapes displaying services are symbolic -o- Road Sign
representations and whilst they are accurately e Bollard
placed they are not to scale. oO Traffic light
We Project Urban Pty Ltd hereby ° 5 10 15 20 Metres &> Tree
certify that the levels and detail shown t T I T I I ] Other Features noted on Face of Plan
hereon are an accurate representation of Original Seale 150
the site at the time of survey.
CLIENT
J A DEVELOPMENT TRUCTI NOTES AMENDMENTS DATE DESIGNED
PROJ F( DELUCA D OPMENT 8 CONSTRUCTION SHEET NO | OF | --SHEETS
PROJECT A
VERTICAL DATUM: AHD
©) CONTOUR & DETAIL SURVEY PSM 2721 RL:76-102 B SURVEYED COMPUTER FILE
COMPLETED 09/09/2019 C RL 19304_CD_C3D2018_110919.dwg
on
N S| CONTOUR INTERVALS D DRAWN SCALE
Sunshine Coast info@ProjectUrban-com-au 32 VIEWLAND DRIVE MAJOR: |Om E RL I:150@ Al
tel: O7 5443 2844 www-ProjectUrban-com-au | NOQSA HEADS, QLD 4567 MINOR: O-25m
Brisbane Project Urban Pty Ltd ‘ F DATE DRAWING No AMEND
\ ter O7 3257 4371 ACN 608 895 923 ABN 97 608 895 923 LOT | on RP226728 G 1/09/2019 19304-CD-Ol

 

 
Log in to download the original file

Contour & Detail Survey.pdf · 1.6 MB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.