07/1014 - Op Works - Landscaping, Carparking, Access, Frontage [As Published] · 142007.1014
S$
RM
‘SW
W
——000 900 ————
SEWER AND SANITARY
TRADEWASTE DRAIN
PIPE CAST OR RUN IN
CONCRETE SLAB {REF DETAIL)
EXISTING SEWER
GAS LINE
RISING MAIN [PUMP OUT |
STORMWATER ORAIN
EXISTING STORMWATER DRAIN
EXISTING WATER SERVICE
COLD WATER SERVICE
RAINWATER / TANK WATER
FIRE SERVICE =>
PIPE RISER OR GROPPER
SANITARY FIXTURE
WATER FIXTURE
CONTROL VALVE {CV}
TEMPERING VALVE
FIXTURE P/TRAP
HOSE COCK (HC)
BALL COCK
STUDOR VENT
WATER CLOSET
+--+ HOT WATER FLOW
etme reese HOT WATER RETURN
me ee ee HOT WATER TEMPERED
wanna mam VENT PIPE
wee ee = AGRICULTURAL DRAIN
SINK
BASIN
ALL WORK IS TO BE CARRIED OUT IN ACCORDANCE WITH AS/NZS 3500 & THE
BUILDING CODE OF AUSTRALIA AND ANY AMENDMENT TO THIS ACT OR A.S. STANDARD.
ALL FIRE SERVICES WORK SHALL BE CARRIED OUT IN ACCORDANCE THE BUILDING CODE
OF AUSTRALIA, AS 2419, AS 2941 AND AS 2441 AND THE RELEVANT AUSTRALIAN
STANDARDS MENTIONED IN THESE CODES.
ALL 100mm SEWER DRAINAGE MIN. 1:60 MIN UNLESS NOTEO OTHERWISE.
ALL STORMWATER DRAINAGE MIN, 1:100 UNLESS NOTED OTHERWISE.
ALL 10's UNDER CONCRETE TO BE TAKEN TO SURFACE LEVEL.
CONTRACTOR 10 VERIFY ALL IL’s AND SL‘s AND COVER OF DRAINAGE. ARE CORRECT
AND OBTAINABLE BEFORE COMMENCEMENT.
ALL UNVENTED BRANCH DRAINS SHALL NOT EXCEED 10m TO THE WEIR OF THE
FIXTURE TRAP.
CONTRACTOR TO CHECK WITH: THE CERTIFYING OFFICER AND / OR SHIRE/CITY
ENGINEER, CHIEF BUILDING SURVEYOR ANO PLUMBING INSPECTOR FOR INTERPRETATION
OF ALL RELEVANT CODES.
THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ARCHITECT’s, ENGINEER'S &
ALL OTHER PROJECT DRAWINGS AND SPECIFICATIONS.
ALL HW & CW WATER LINES TO BE {Smm TO INDIVIOUAL FIXTURES UNO NOTED
OTHERWISE. ALt COLD WATER SUPPLY LINES INCLUDING SUPPLY LINES TO HW UNITS
(H.W.U.) TO BW 20mm UNLESS OTHERWISE NOTED.
DISHWASHER
LEGEND NOTES
/ 178 SERVICES No. (0 CLEAR OUT HL HIGH LEVEL 10 TUNDISH
Cw COLD WATER HV HYDRANT VALVE 1G TESTGATE
CWR SERVICES NAME w COPPER iosl 10. TO SURFACE LEVEL WV TEMPERING VALVE
\ 2554 cv CONTROL VALVE io INSPECTION OPENING TWD TANK WATER DROPPER
SERVICES SIZE 0G DISCONNECTOR GULLY IL INVERT LEVEL TwR TANK WATER RISER
- DAP DUCT ACCESS PANEL MH MANHOLE UNO UNLESS NOTED OTHERWISE
(wR COLD aR ee ) EXPANSION JOINT NTs NOT TO SCALE UR URINAL
DP DOWNPIPE FHR FIRE HOSE REEL ORG OVERFLOW RELIEF GULLY ve VENT COWL
FSR FIRE SERVICE RISER FL FLOOR LEVEL POLY POLYETHELENE PIPE vP VENT PIPE
FU FIXTURE UNITS FWG FLOOR WASTE GULLY PVC POLY VINYL CHLORIDE
HWD HOT WATER DROPPER FS FIRE SERVICE RCP REINFORCED CONCRETE PIPE
HWR HOT WATER RISER GsT GREASE SILT TRAP RHS RECTANGLE HOLLOW SECTION
RV RELIEF VENT ov GATE VALVE RL REDUCED LEVEL
ST STACK GVM GATE VALVE MONITORED RWO RAINWATER OUTLET
GST GREASE STACK Gw GLASS WASHER spo SPOON DRAIN OUTLET
EP ELEVATED PIPE HC HOSE COCK SEW SEWER
FW INDEPENDANT FLOOR Hw HOT WATER st SURFACE LEVEL
WASTE DROPPER HWU HOT WATER UNIT Sw STORMWATER
TEST TEST DRAIN
ALL HOT WATER UNITS {HWU) SHALL BE AS LISTED ON THE DWG’s.
PROVIDE EXPANSION JOINTS AND TEST GATES AS REQUIRED BY THE A.S. 3500 AND
WHERE OIRECTED BY THE COUNCIL.
ALL SEWER DRAINAGE SHALL BE:-
() UNDERGROUND SEWER DRAINAGE SHALL 8E PVC PIPES AND FITTINGS OR VCP
OR HOPE PIPES AND FITTINGS AS NOTEO.
ALL SANITARY PLUMBING SHALL BE:-
() PVC PIPES AND FITTINGS AS 1415. PROVIDE FIRE COLLARS TO ALL
PENETRATIONS WHERE FIRE RESISTANCE RATING IS REQUIRED.
ALL EXTERNAL UNDERGROUND WATER SHALL BE:-
() HIGH DENSITY POLYETHELENE PIPE A.S. 1159 AND APPROVED FITTINGS. WHERE
INDICATED
{2} COPPER PIPE AND FITTINGS A.S.1432 TYPE "B” "POLYLAG" / "KEMLAG”
WHERE INDICATED.
(3) BLUE BRUTE WHERE NOTED ON THE DRAWINGS.
ALL INTERNAL WATER RETICULATION SHALL BE:~
(i COPPER PIPE AND FITTINGS A.S.1432 TYPE ”
(2) CROSSED LINKED HIGH DENSITY POLYETHYLENE TO AS 2537 AND BRASS
FITINGS TG AS 2492 “REHAU” OR APPROVED EQUAL WATER SERVICE.
THE CONTRACTOR SHALL CHECK PRIOR TO THE INSTALLATION OF ALL EQUIPMENT,
FIXTURES AND FITTINGS ANO IN PARTICULAR DISHWASHERS AS TO THE REQUIREMENT
FOR PRESSURE LIMITING VALVES OR ANY OTHER VALVES OR EQUIPMENT WHICH MAY
BE NECESSARY FOR THE CORRECT OPERATION OF THE EQUIPMENT OR FIXTURES.
THE CONTRACTOR SHALL INSTALL BACKFLOW PREVENTION VALVES AND FITTINGS
WHERE REQUIRED BY AS/NZS 3500. THE POSITIONING AND INSTALLATION SHALL BE
CARRIED OUT BY CERTIFIED INSTALLERS.
CONTRACTOR TO REFER TO EQUIPMENT MANUFACTURER'S INSTALLATION GUIDE FOR
EXACT LOCATION OF SERVICES REQUIRED FOR SATISFACTORY CONNECTION OF
EQUIPMENT.
MAINTAINENCE AGREEMENTS -- HYDRAULIC SERVICES THE CONTRACTOR SHALL
ARRANGE AS PART OF THE CONTRACT A MAINTENANCE AGREEMENT WITH A APPROVED
CERTIFIER TO SERVICE ALL ASPECTS OF THE INSTALLATION AND CARRY OUT
MAINTENANCE CHECKS IN ACCORDANCE WITH THE RELEVANT CODES, THIS AGREEMENT
IS TO BE IN PLACE FOR A PERIOD OF 12 MONTHS & THEN TRANSFERED OVER TO THE
BUILDING OWNER AND OR THE BODY CORPORATE. ALL SERVICES WHICH FORM PART OF
THE HYDRAULIC SERVICES CONTRACT ARE TO BE INCLUDED IN THIS MANAGENT PLAN
ALONG WITH DOCUMENTATION ON ALL ASPECTS OF EQUIPMENT FIXTURES & FITTINGS
USE IN THE BUILDING.
ECEIVE
- 9 OCT 2006
BY:
ty | Sos.200¢ Trevistd APPROVAL
or DATE REVISIONS 7 ISSUE
GENT
KYM & CAMILLE HENDRIE
AND ANNETTE WARNER
PROACT
3 CORSAIR CRESENT
SUNSHINE BEACH
HYDRAULIC COMSUL TANT
Brian Bumett gow
& Associates ‘ansca
HYDRAULIC CONSULTANTS
CABRINI PTY LTD ABN 53 494 887 081
BSA LICENCE NO, 887442
P.O. Box 646, COTION TREE, Qld 4558
suv [Q. NGUYEN crceoey | BRB
saat | WATS, aon | AS
OF OFNGAAL
ror oaTe | 2006.09.27 = atv. B
mm | 06057
10/43 The Esplanade Matoochydore COMPUTER REF:
ad Phone: 07 5443 1000 " 90652 ows ret. | H-NE-OF
Fox: 07 5443 1136
Email: [email protected] mle
NOTES & LEGEND
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1014 - Op Works - Landscaping, Carparking, Access, Frontage [As Published]Related documentApplication case desk ↗
About this file
- File size
- 1.8 MB (small file)
- File type
No other editions are linked here.