Original source · versioned page text
Compiled Approved Plans MCU18-0189.02
Plans and drawings: the text below has words only, no drawings.
Very large file (22.6 MB): may take a few minutes to open.
AREA CALCULATIONS:
LEGEND
PROPOSED WORKS
BUILDINGS TO BE DEMOLISHED:
GFA: (133m2)
SK-02
1. SENIOR SCHOOL GLA / STAFF BUILDING IMPERVIOUS AREA: (218m2)
2. DOUBLE STOREY COVERED WALKWAY TO BLOCK H
SENIOR / STAFF BUILDING:
GFA: Ground Floor 402m2
EXISTING BUILDINGS First Floor 396m2
A. DOUBLE STOREY BLOCK H
Total 798m2
1st FLOOR - SCIENCE LABS x 2, STAFFROOMS, STORAGE IMPERVIOUS AREA: 825m2
2nd FLOOR - DRAMA, MUSIC, CHAPLAINS, STAFFROOM, GLA
B CHAPEL
TOTAL DIFFERENCE:
LOCATION PLAN
C. BLOCK L
SEWER PUMP GFA: 665m2
LEARNING RESOURCE CENTRE
B
COMPUTER LAB
R BUILDERS SITE COMPOUND IMPERVIOUS AREA: 607m2
TUCKSHOP
U location indicative only to be confirmed with
ICT SUPPORT
C college & architect prior to commencement
D. BLOCK C
E of work
EARLY LEARNING CENTRE H NEW SENIOR / STAFF BUILDING
KINDY W
PREP Y BUILDERS SITE FENCING
to portion of open area
E. BLOCK A
ADMINISTRATION
LEARNING ENHANCEMENT DEMOLISH P BLOCK
make good of remaining structure, finishes &
surrounds and reinstate topsoil & turf as specified.
F. BLOCK B Sports Multi Purpose
YEAR 1 and YEAR 2
Field Courts
G. BLOCK D
YEAR 4 and YEAR 5
H. BLOCK E
YEAR 3 and YEAR 6 DEMOLISH M BLOCK
make good of remaining structure, finishes &
I. THE BARN surrounds and reinstate topsoil & turf as specified.
MAINTENANCE
J. PRIMARY UNDERCOVER AREA
Sports
Field 1
K. AMENITIES
( PRIMARY )
O P
L. SENIOR SCHOOL GLA BUILDING 2
M. SENIOR SCHOOL GLA BUILDING GATES FOR
- TO BE DEMOLISHED PEDESTRIAN ACCESS
N. SENIOR SCHOOL GLA BUILDING SITE ACCESS ROAD L
Builder to provide all weather access as
O. MAINTENANCE SHED required. make good to match existing A
finish upon completion of project.
P. AMENITIES
( SENIOR )
- TO BE DEMOLISHED
SOLID HOARDING M
as required to protect students and existing
building during construction / connection of new
N JOB:
covered walkway link.
NCC01
B
J
DATE:
6/7/20
I K
G
GROUNDSMEN ACCESS
maintenance access to be maintained. Builder to E C
liaise with college for their access requirements H
and coordinate site fencing accordingly.
SITE GATE ENTRY / EXIT F
OAD
SITE ACCESS ROAD
KR
to be made good on completion
of project to match existing.
REE
LI C
Pick Up
BEL
D and Drop Off
ROY
Carpark
COO
17 SHORT ST SOUTHPORT QLD 4215 AUSTRALIA
PO BOX 930 SOUTHPORT QLD 4215 AUSTRALIA
P +61 7 5532 2044 / ABN 35 071 453 257
SITE ENTRY CONSTRUCTION VEHICLES
from Cooroy Belli Creek Road
LEGEND
[email protected]
EXISTING BUILDING
SITE ENTRY SHARED ZONE
Site entry through college carpark, delivery periods to be limited to
N
BURLINGBROWN.COM
minimise traffic with parent dropoff & pickup times, refer Access to Works
PROPOSED NEW SENIOR BUILDING in specification. Confirm with College prior to commencement of works.
PROPOSED COVERED WALKWAY
LOCATION PLAN
EXISTING GLA DEMOUNTABLE TO BE DEMOLISHED PROPOSED SENIOR / STAFF BUILDING SCALE 1:2000@A3
EXISTING AMENITIES DEMOUNTABLE TO BE DEMOLISHED
0 20 40 60 100m -
NOOSA COUNCIL
_TENDER ISSUE
LOCATION PLAN
NOT FOR
CONSTRUCTION
NOOSA CHRISTIAN COLLEGE
APPROVED PLAN
PROPOSED SENIOR / STAFF BUILDING
LOCATION: 20_Cooroy Belli Creek Rd_Cooroy_QLD_4563.
MCU18/0189.01 11 AUG 2020
ISSUE
P10
Document Set ID: 21215697
21164915
Version: 4,
1, Version Date: 17/08/2020
10/07/2020
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.
Full text of the other 15 pages
Page 2
(
133m2)
(
218m2)
665m2
607m2
-
NOOSA COUNCIL
APPROVED PLAN 9
MCU18/0189.01 11 AUG 2020
Document Set ID: 21215697
21164915
Version: 4,
1, Version Date: 17/08/2020
10/07/2020
Page 3
GROUND FLOOR AREAS existing 5.3m high acoustic
ADMIN 58 barrier to northern site
CLEANER STORE 4 boundary to the Bruce
CORRIDOR 8 Highway.
SK-04
COURTYARD 32 indicative landscape
COVERED WALKWAY 58 buffer. refer 3,000 10,620 4,210 3,000
DATA RACK 3 landscape drawings 10,000 ADMIN BO
F.L.A. 1 86 for more details UN
STORE
F.L.A. 2 86 3,390 DA
10,000FLA1
FEMALE AMENITIES 32 RY
MALE AMENITIES 30
3,502STORE
PE STORE 25 STAIRS
GROUND FLOOR PLAN
SERVICE CORRIDOR 35 STAFF
STAFF STORE 19 STORE
4.2MX3.5M
STAIR 19
STORE / WTHDRWL 01 23 CLNR
STORE / WTHDRWL 02 23 STORE
TIERED SEATING
1.5MX1.1M k'nette 10
5,370ADMIN
TIERED SEATING 25 M
UNISEX PWD 10 ADMIN BU
10MX5.35M
VERANDAH 107 COURT FF
683 m2 YARD ER
3.4MX3M
7.6MX3.7M ZO
NE
t e a c h i n g w a ll + s t o r a g e
VERANDAH
whiteboard
faced doors
8,190FLA1
33MX3M
WITHDRAWAL
ROOM 01
F.L.A. 1
5.8MX3.4M
STORE /
10MX8.2M
sldr
33,122
o p e r a b l e w a ll
WITHDRAWAL
JOB:
NCC01
ROOM 02
5.8MX3.4M
STORE /
sldr
EXISTING
8,230FLA2
F.L.A. 2 BUILDING DATE:
10MX8.2M to be 17/4/19
demolished
whiteboard
faced doors
t e a c h i n g w a ll + s t o r a g e CORRIDOR
AREA CALCULATIONS: 3.7MX2M
EXISTING
3,175MALE
BUILDING
BUILDINGS TO BE DEMOLISHED:
perforated screen
AMB.
GFA: (283m2) MALE AMEN. PE
3,150PWD
IMPERVIOUS AREA: (408m2) 10MX3.2M
UNISEX STORE
6.8MX3.4M
3,175FEMALE
PWD
SENIOR / STAFF BUILDING: 3.3MX2.6M FEMALE AMEN.
GFA: Ground Floor 402m2 10MX3.2M
AMB.
First Floor 396m2 10,000AMENITIES
17 SHORT ST SOUTHPORT QLD 4215 AUSTRALIA
PO BOX 930 SOUTHPORT QLD 4215 AUSTRALIA
Total 798m2
P +61 7 5532 2044 / ABN 35 071 453 257
IMPERVIOUS AREA: 825m2
TOTAL DIFFERENCE:
WALKWAY
COVERED
18MX3M
GFA: 515m2
DATA
[email protected]
IMPERVIOUS AREA: 417m2
RACK
BURLINGBROWN.COM
1.7MX0.7M
N
GROUND FLOOR PLAN
SCALE 1:200@A3
0 2 4 6 10m - _PRELIMINARY
NOOSA COUNCIL
ISSUE
GROUND FLOOR PLAN
NOT FOR
CONSTRUCTION
APPROVED PLAN
NOOSA CHRISTIAN COLLEGE
PROPOSED SENIOR / STAFF BUILDING
LOCATION: 20_Cooroy Belli Creek Rd_Cooroy_QLD_4563.
MCU18/0189 1 MAY 2019 ISSUE
P14
Document Set ID: 21215697
20853068
20856084
Version: 4,
1, Version Date: 17/08/2020
2,
3, 18/04/2019
03/05/2019
Page 4
FIRST_FLOOR_AREAS existing 5.3m high acoustic
COLD ROOM 11 barrier to northern site
COVERED WALKWAY 58 boundary to the Bruce
G.L.A. 1 85 Highway.
SK-05
G.L.A. 2 82 indicative landscape
HOSPITALITY 118 buffer. refer 14,570
OUTDOOR LEARNING AREA 63 landscape drawings 3,390STORE BO
STAIRS 22 for more details 310 10,000GLA1 / HOSPITALITY UN
STORE 12 DA
STORE / WTHDRWL 03 24 line of roof over RY
STORE/ LDRY 22
3,502STAIRS
VERANDAH 106 STAIRS low level
FIRST FLOOR PLAN
5.8MX3.5M roof
603 m2
t e a c h i n g w a ll + s t o r a g e
WITHDRAWAL
10
whiteboard faced doors
M
ROOM 03
5.89MX3.4M
STORE /
screen designed to allow view and control western sun
BU
5,940
8,000GLA1
FF
G.L.A. 1 ER
10MX8M ZO
NE
V ERA NDA H
2,810
COLD
ROOM
33MX 3M
5,777 105
line of roof over
11,452HOSPITALITY STORE/
33,622
LDRY
HOSPITALITY DRY
11.5MX10M ROOM
3,068STORE 02
JOB:
STORE NCC01
02
3.08MX2.8M
EXISTING
BUILDING DATE:
to be 17/4/19
servery window demolished
AREA CALCULATIONS:
9,137OUTDOOR LEARNING
EXISTING
OUTDOOR BUILDING
11,550
BUILDINGS TO BE DEMOLISHED:
GFA: (283m2)
LEARNING
AREA
IMPERVIOUS AREA: (408m2) 9.1MX6.9M G.L.A. 2
10.74MX6.8M
SENIOR / STAFF BUILDING:
GFA: Ground Floor 402m2
First Floor 396m2
17 SHORT ST SOUTHPORT QLD 4215 AUSTRALIA
PO BOX 930 SOUTHPORT QLD 4215 AUSTRALIA
Total 798m2
P +61 7 5532 2044 / ABN 35 071 453 257
IMPERVIOUS AREA: 825m2
TOTAL DIFFERENCE:
WALKWAY
COVERED
GFA: 515m2 line of roof over
18MX3M
[email protected]
IMPERVIOUS AREA: 417m2
BURLINGBROWN.COM
N
FIRST FLOOR PLAN
line of roof over
SCALE 1:200@A3
_PRELIMINARY
0 2 4 6 10m -
NOOSA COUNCIL
ISSUE
FIRST
PROPOSEDFLOOR PLAN
NOT FOR
CONSTRUCTION
NOOSA CHRISTIAN COLLEGE
APPROVED PLAN
SENIOR / STAFF BUILDING
LOCATION: 20_Cooroy Belli Creek Rd_Cooroy_QLD_4563.
MCU18/0189 1 MAY 2019
ISSUE
P13
Document Set ID: 21215697
20853068
20856084
Version: 4,
1, Version Date: 17/08/2020
2,
3, 18/04/2019
03/05/2019
Page 5
feature screen
tiered seating
lightweight
balustrade
colorbond
sunscreen
colorbond
brickwork
brickwork
cladding
cladding
cladding
walkway
covered
feature
SK-06
TOP OF ROOF TOP OF ROOF
R.L. +123.700 R.L. +123.700
2,500
2,500
ROOF
R.L. +121.200 R.L. +121.200
3,000
3,000
ELEVATIONS
9,000
9,000
FIRST FLOOR
R.L. +118.200 R.L. +118.200
3,500
3,500
GROUND FLOOR
R.L. +114.700 R.L. +114.700
NORTH ELEVATION SOUTH ELEVATION
SCALE 1:200@A3 SCALE 1:200@A3
colorbond metal
0 2 4 6 10m 0 2 4 6 10m
tiered seating
brickwork
20m long
cladding
walkway
covered
TOP OF ROOF
R.L. +123.700
2,500
ROOF
R.L. +121.200
3,000
9,000
JOB:
FIRST FLOOR NCC01
R.L. +118.200
EAST ELEVATION
3,500
DATE:
SCALE 1:200@A3 17/4/19
0 2 4 6 10m GROUND FLOOR
R.L. +114.700
colorbond roof
balustrading
sunscreens
lightweight
perforated
perforated
20m long
cladding
walkway
sheeting
covered
feature
feature
screen
metal
-
TOP OF ROOF
NOOSA COUNCIL
17 SHORT ST SOUTHPORT QLD 4215 AUSTRALIA
R.L. +123.700
PO BOX 930 SOUTHPORT QLD 4215 AUSTRALIA
2,500
P +61 7 5532 2044 / ABN 35 071 453 257
APPROVED PLAN ROOF
MCU18/0189 1 MAY 2019 R.L. +121.200
3,000
9,000
[email protected]
FIRST FLOOR
BURLINGBROWN.COM
R.L. +118.200
WEST ELEVATION
3,500
SCALE 1:200@A3
0 2 4 6 10m GROUND FLOOR
R.L. +114.700
_PRELIMINARY
ISSUE
ELEVATIONS
NOT FOR
CONSTRUCTION
NOOSA CHRISTIAN COLLEGE
PROPOSED SENIOR / STAFF BUILDING
LOCATION: 20_Cooroy Belli Creek Rd_Cooroy_QLD_4563.
ISSUE
P10
Document Set ID: 21215697
20853068
20856084
Version: 4,
1, Version Date: 17/08/2020
2,
3, 18/04/2019
03/05/2019
Page 6
PROPERTY DESCRIPTION EXISTING BUILDINGS
Location: 20 COOROY BELLI CREEK ROAD, COOROY, LEGEND
A. DOUBLE STOREY BLOCK H
QLD, 4563 -
EXISTING BUILDING
1st FLOOR - SCIENCE LABS x 2,
STAFFROOMS, STORAGE
2nd FLOOR - DRAMA, MUSIC,
Lot: LOT 9 on RP209025 NOOSA COUNCIL PROPOSED NEW WORKS
CHAPLAINS, STAFFROOM, GLA
Local Authority Area: NOOSA SHIRE COUNCIL APPROVED PLAN
SK-10
B CHAPEL
Parish: TEWANTIN MCU18/0189.01 11 AUG 2020 PROPOSED REFURBISHMENT WORKS C. BLOCK L
LEARNING RESOURCE CENTRE
County of: MARCH COMPUTER LAB
TUCKSHOP
ICT SUPPORT
D. BLOCK C
EARLY LEARNING CENTRE
KINDY
PREP
E. BLOCK A
ADMINISTRATION
LEARNING ENHANCEMENT
PROPOSED SITE PARKING PLAN
F. BLOCK B
YEAR 1 and YEAR 2
G. BLOCK D
YEAR 4 and YEAR 5
H. BLOCK E
YEAR 3 and YEAR 6
I. THE BARN
MAINTENANCE
J. PRIMARY UNDERCOVER AREA
K. AMENITIES
( PRIMARY )
B
R L. SENIOR SCHOOL GLA BUILDING
U
C M. SENIOR & STAFF BUILDING
E
H N. SENIOR SCHOOL GLA BUILDING
W
Y O. MAINTENANCE SHED
Sports Multi Purpose
Field Courts
INDUSTRIAL ARTS
Sports 2
NEW SHED: 54m
INFILL EXISTING AWNING: 36.5m2
Field M
JOB:
O
NCC00
DATE:
L 20/7/22
A
REFURBISH
EXISTING ADMIN
1 x GLA, BREAKOUT,
STORAGE, WASH-UP &
TEACHER ROOM
REFURBISHED GFA: 107.4m2
N
B
J
I STAFF PARKING
K 27 CAR SPACES
G
LEARNING RESOURCE
CENTRE
H E C REFURBISHMENT &
EXTENSION
STAFF PARKING NEW ADMINISTRATION & OFFICES
9 CAR SPACES F NEW GFA: 86.6m2
REFURBISHED GFA: 163.9m2
OAD
17 SHORT ST SOUTHPORT QLD 4215 AUSTRALIA
PO BOX 930 SOUTHPORT QLD 4215 AUSTRALIA
P +61 7 5532 2044 / ABN 35 071 453 257
KR
BUS PARKING
REE
PWD
5 SPACES
LI C
BEL
D
[email protected]
ROY
STAFF PARKING Carpark
BURLINGBROWN.COM
4 CAR SPACES
COO
PROPOSED PARKING STAFF PARKING
LEGEND 4 CAR SPACES
PICK-UP/DROP-OFF
CAR PARKING (VISITOR) - 73 SPACES 4 CAR SPACES
CAR PARK
CAR PARKING (PWD) - 1 SPACE
QUEING AREA 38 EXISTING CAR SPACES
14 CAR SPACES 35 NEW CAR SPACES
1 PWD & SHARED SPACE
PICK-UP/DROP-OFF - 4 SPACES TOTAL: 73 SPACES + PWD
QUEING AREA - 14 SPACES
_PRELIMINARY
BUS PARKING - 5 SPACES
ISSUE
CAR PARKING (STAFF) - 44 SPACES NOT FOR
CONSTRUCTION
NOOSA CHRISTIAN COLLEGE
N PROPOSED SITE PARKING PLAN
NOOSA CHRISTIAN COLLEGE MASTER PLAN
LOCATION: 20_Cooroy Belli Creek Rd_Cooroy_QLD_4563.
NOOSA CHRISTIAN COLLEGE MASTER PLAN
0 10 20 30 40 60 80m
SCALE 1:1000@A1
ISSUE
P2
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 7
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 8
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 9
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 10
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 11
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 12
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 13
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
MP-04
LEGEND
EXISTING BUILDING
PROPOSED NEW SHED
PROPOSED AREA OF INFILL
UNDER EXISTING ROOF
SHED ADDITION LOCATION PLAN
BO
UN
Sports Multi Purpose DA
Field Courts RY BR
UC
E
HI
GH
W
AY
Sports
Field
BO
UN
DA
RY
JOB:
NCC00
DATE:
28/6/2022
RY
NDA
BOU
OAD
KR
REE
LI C
BEL
ROY
COO
Carpark
17 SHORT ST SOUTHPORT QLD 4215 AUSTRALIA
PO BOX 930 SOUTHPORT QLD 4215 AUSTRALIA
P +61 7 5532 2044 / ABN 35 071 453 257
BOUNDA
RY
[email protected]
BURLINGBROWN.COM
PROPOSED SHED ADDITION N _PRELIMINARY
LOCATION PLAN ISSUE
NOT FOR
NOOSA CHRISTIAN COLLEGE MASTER PLAN SCALE 1:1000@A1
CONSTRUCTION
NOOSA CHRISTIAN COLLEGE
NOOSA CHRISTIAN COLLEGE MASTER PLAN
0 10 20 30 40 60 80m
ISSUE
LOCATION: 20_Cooroy Belli Creek Rd_Cooroy_QLD_4563. P1
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 14
UN
DA
RY
PROPERTY DESCRIPTION
Location: 20 COOROY BELLI CREEK ROAD, COOROY,
QLD, 4563
Lot: LOT 9 on RP209025
Local Authority Area: NOOSA SHIRE COUNCIL
MP-05
Parish: TEWANTIN
County of: MARCH
BR
UC
-
NOOSA COUNCIL BO
UN
SHED ADDITION SITE PLAN
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
DA
E
RY
HI
CO GH
W
NC
RE
AY
TE
AC
OU
ST
IC
W
AL
L
EXISTING EX.
19,800
BUILDING TANK
926
EX.
SHADE SAIL
6,035
25,065
18,300
JOB:
6,133
EX. NCC00
ROOF
9,000
EX. PROPOSED
5,957
PROPOSED
INFILL
SHED SHED
fall fall fall fall fall DATE:
28/6/2022
1,000 6,000
EX.
SHADE SAIL BO
2,034
2,000
UN
DA
RY
EXISTING
BUILDING
EXISTING
BUILDING
17 SHORT ST SOUTHPORT QLD 4215 AUSTRALIA
PO BOX 930 SOUTHPORT QLD 4215 AUSTRALIA
P +61 7 5532 2044 / ABN 35 071 453 257
[email protected]
BURLINGBROWN.COM
PROPOSED SHED ADDITION SITE N _PRELIMINARY
PLAN ISSUE
NOT FOR
NOOSA CHRISTIAN COLLEGE MASTER PLAN SCALE 1:200@A1
CONSTRUCTION
NOOSA CHRISTIAN COLLEGE
NOOSA CHRISTIAN COLLEGE MASTER PLAN
0 2 4 6 8 12 16m
ISSUE
LOCATION: 20_Cooroy Belli Creek Rd_Cooroy_QLD_4563. P1
Document Set ID: 22129441
Version: 1, Version Date: 06/10/2022
Page 15
Roof: Mountain Blue Trimclad -
Trim: Mountain Blue NOOSA COUNCIL
Gutter Type: Quad APPROVED PLAN
MCU18/0189.01 11 AUG 2020
Walls: Smooth Cream Vertical Trimclad
Roller Doors: Smooth Cream / Smooth Cream
Roof Insulation: None
Wall Insulation: None
©2022 Mecano Sheds Pty Ltd
MecanoSet
Document Sheds Pty Ltd
ID: 22129441 File : arch_elevation.pdf Page 1 of 1 Client : College, Jack Presecan /Noosa Christian Page 8 Q37526
Version: 1, Version Date: 06/10/2022
Page 16
-
NOOSA COUNCIL
APPROVED PLAN
MCU18/0189.01 11 AUG 2020
©2022 Mecano Sheds Pty Ltd
MecanoSet
Document Sheds Pty Ltd
ID: 22129441 File : arch_floorplan.pdf Page 1 of 1 Client : College, Jack Presecan /Noosa Christian Page 9 Q37526
Version: 1, Version Date: 06/10/2022