Original source · versioned page text
SUPERSEDED - Approved Plans - MCU22-0097
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn CARPARKS to AS2890.1
20 Carspaces allows for Existing Palm Grove
Fig 2.2 for 90°park
Class 3 Short Term 120m2 'use' area LOT 1 PROP
ERTY
BOUN
DA RY
Length 5400mm
PROPERTY BOUNDARY
Width 2600mm
Aisle 5800mm
1.85 m
Motorbike park x2 ' 00" 6
79° 44
10
STREE
T SIGN 9
8
7
6
5
4 Soft Landscapes
179° 59' 40" 19.39 m
3
1 2
5400
413.5m²
DRIVE
Bollards
G
EXISTIN R W ALKW A
Y
CROSS
OV E TRIAN Entry Roof over
PEDES
TURE
STRUC
EXISTIN
G CARPARK
6000
PW D
KW AY
PROP
TRIAN
W AL 20
PEDES
ERTY
ENTRY
19
18
RESE
BOU
17
16
NDAR
15
14
13
Y
5400
12 GATE
11
Bicycle Parking x 6 Existing Large Gum Tree
RVE S
RAMP
795
LOT 2
11000
5°
15°
15°
TREE
loading
ST R UCTUR
E 5°
EX ISTING
PROPOSED
a
SEATING
rea
STUCTURE
AREA 130.5m² BOU NDAR
Y
ERTY
PROP
179° 59' 40" 11.27 m
349° 2
T
30.28 m
15°
4' 00"
259° 4
3' 20"
SCREENED
BIN
ENCLOSURE
29.19
m
ING
- EXIST RE
TU
APPROVED PLAN RE S T R UC
RUCTU
MCU22/0097 EXIST E
ING EXIST
ING ST
LOT 7 COUNCIL ANNOTATION
NOOSA COUNCIL TURE S T R U C TU R
STRUC
3 JANUARY 2023 EX ISTING
The highlighted area is not
RE
RUCTU
ING ST
EXIST
approved as a use area in
conjunction with the
1 CARPARK
4.1 1 : 200 development permit i.e., no
outdoor dining.
CD4dSTRUCTURE
IN G
new build REV DESCRIPTION DATE EXIST
SITE PLAN JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.Walker
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 1.2
SCALE(A3): 1 : 200
Document Set ID: 22197990
Version: 1, Version Date: 02/12/2022
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 7 pages
Page 2
AREA SCHEDULE
TOILET 16 m²
BAR 16 m²
SMOKE HOUSE KIT 58 m²
COOLROOM 11 m² CAR PARKING
BOH 28 m² 1
DECK 50 m² 6.2
179 m² 4.1
4000 6000 5500 N 5500
6490
ENTRY
GATE
New Timber Fence Line New Timber Fence Line
A
90
DP
clear
1000
1000
1000
D.15
W.24 1:8 DDA RAMP
ice
HWD
pass BAL
W.23
EQ
EQ
STAIR
W.22
7000
plate up
E 4.1
BOH DECK HWD
pass
W.21
W
7000
4.2
49.6 m2
A KITCHEN/ SMOKE HOUSE W.20
EQ
EQ
6.1 59m2 PATRON AREA
10000
W.19
W.16 W.15 W.14
D.20 HWD
D.22 DP
90
DP
RL 41635
1205
D.14
D.25 DP
B
90 1020 90
90
400
high
950
COLD ROOM W.17 bar RL 41035
3820
4000
STORE
bar flap
D.18 D.19 D.16
DISH BAY
2820
3000
D.17
1270
Fenced
ACCESS
BAR
STAFF
Bin Area
1710
D.11
WC
600
plate up STORE
back
C
90
90
480
Mop Bucket
SEWER & SERVICES new fence line
PROPERTY BOUNDARY 2140 90 1000 90 1000 90 New Timber Fence Line
259° 44' 00" 30.28 m
6000 5410 100 3230 90 1000 90 1000 90
6000 11010
5500
S
DISTILLERY
-
APPROVED PLAN 4.2
MCU22/0097
NOOSA COUNCIL 1 2 3 4 5
3 JANUARY 2023
0 1 2 3 4m
1:100
CD4d
new build REV DESCRIPTION DATE
GROUND FLOOR JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.Walker
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 1.3
SCALE(A3): 1 : 100
Document Set ID: 22197990
Version: 1, Version Date: 02/12/2022
Page 3
-
APPROVED PLAN
MCU22/0097
NOOSA COUNCIL
3 JANUARY 2023
NOTES:
4080 6000 5420
All work to conform with Part MP 4.2 of the Queensland
Development Code (QDC) (Water Saving Targets). 15500
Roof stormwater is to discharge to local government 21180
requirements and approval. Downpipes not connected 35°
to rainwater tank/s to discharge to interallotment
drainage system/ to nominated discharge points via
bubbler system/ to discharge to street channel system.
Based on assumed 5 minute rainfall intensity - 248mm/h STORMWATER
20 years recurrence interval. TO EXISTING
LAWFUL POINT
Gutters & downpipes shall be in accordance with OF DISCHARGE
AS/NZS3500.5 domestic & Part 3.5.2, Vol 2 of the NCC.
DP
455
All downpipes to be 90mm/100mm U-PVC.
All gutters to be 150 Quad Gutters (8600mm² Cross section area).
Falls to be in accordance with clause 3.5.2.4, Vol 2 of the NCC.
• Effective roof catchment area 183.0m²
• Number of downpipes 4
• Roof catchment per downpipe 45.75m²
• Downpipes must not serve more than 12m of gutter length for each
downpipe EG
• Total rainfall intensity 183m² X 248mm/45.75= 992L/min 5°
• Stormwater pipes - 100 dia. Laid at 1 in 100 minimum grade. 5°
Downpipes are to be located where they will not 15° 15°
create a hazard to building users nor impede window
EG
& door openings and the like. They are to be installed
11120
as close as practicable to the supporting structure
while maintaining termite inspection clearances of
25mm. Downpipes are to be protected from potential
mechanical damage, be installed no less than 100mm
from electrical cables & gas pipes & no less than 50mm DP
from other services (AS3500.3.2 S4.11) DP
EG
Downpipes are to service 12m maximum
gutter length & be within 1.2m from each DP
valley unless overflow is provided for
(NCC Vol2 P3.5.2.5)
15°
3090
15°
DP DOWNPIPE ZINCALUME
EG EDGE GUTTER TO MATCH ROOF
CD4d
new build REV DESCRIPTION DATE
ROOF MAIN JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.Walker
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 3.1
SCALE(A3): 1 : 100
Document Set ID: 22197990
Version: 1, Version Date: 02/12/2022
Page 4
DP DOWNPIPE ZINCALUME
5 4 3 2 1
1
6.2
15° 15°
Zincalume Roofing
Rustic Cladding to Metal Cladding to
specificaiton 5° specificaiton 5°
35°
Half Round Gutter ROOF LEVEL
44085
Rustic Entry
Structure DP
2450
Rustic Cladding to DP DP
specificaiton
2450
Timber HWD Railing
FLOOR LEVEL
41635
600
WC Level
41035
Steel Balastrade
to Detail Rustic Cladding to
Steel Balastrade specificaiton
to Detail
N NORTH ELEVATION
1.3 1 : 100
-
C B A APPROVED PLAN
MCU22/0097
A
NOOSA COUNCIL
3 JANUARY 2023
6.1
Zincalume /Galvanised
Roofing
Metal Cladding Type 15°
2 to specification
ROOF LEVEL
44085
Metal Cladding Type
2 to specification Half Round Gutter
4505
Rustic Cladding to Rustic Cladding to
specification specification
GROUND
41135
Steel Balustrade
to Detail
Timber HWD Railing
E EAST ELEVATION
1.3 1 : 100
CD4d
new build REV DESCRIPTION DATE
ELEVATION JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.WALKER
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 4.1
SCALE(A3): 1 : 100
Document Set ID: 22197990
Version: 1, Version Date: 02/12/2022
Page 5
A
A 6.1
B C DP DOWNPIPE ZINCALUME
EG EDGE GUTTER TO MATCH
ROOF
SNK KITCHEN SINK
BOUNDARY LINE
Zincalume Roofing
Half Round Gutter
-
APPROVED PLAN
MCU22/0097
ROOF LEVEL NOOSA COUNCIL
44085 3 JANUARY 2023
Fibre Cement
Cladding to
Rustic Entry BIN AREA specificaiton
Structure
GROUND
41135
Rustic Cladding to
specificaiton
W WEST ELEVATION
1.3 1 : 100
1
1 2 6.2 3 4 5
Zincalume Roofing
Rustic Cladding to Rustic Cladding to
specificaiton specificaiton
15° 35° 35° Rustic Cladding to
Half Round Gutter specificaiton
5°
ROOF LEVEL EG
44085
BIN AREA
Rustic Entry
DP
Structure
SNK
GROUND
41135
Steel Balastrade Timber Fencing
to Detail
S SOUTH ELEVATION
1.3 1 : 100
CD4d
new build REV DESCRIPTION DATE
ELEVATION JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.WALKER
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 4.2
SCALE(A3): 1 : 100
Document Set ID: 22197990
Version: 1, Version Date: 02/12/2022
Page 6
-
APPROVED PLAN
EG EDGE GUTTER TO MATCH ROOF MCU22/0097
HWD 90x140mm HARDWOOD POSTS TO ENGINEERS SPEC. NOOSA COUNCIL
3 JANUARY 2023
1 2 3 4
1
6.2
CLADDING
Zincalume/Galvanised
Corrugated Sheeting
RAFTERS
CLADDING Sissorr Truss to Engineers
Zincalume/Galvanised Spec
Corrugated Sheeting
RAFTERS
RAFTERS
HW D to Engineers Spec
Timber Engineers Spec
5°
5°
ROOF LEVEL
44085 EG
EG
PLASTER HWD Beam
Raking to Truss Underside HWD To Detail
CEILING
Plaster Board Raking HWD Post
SMOKEHOUSE
DECK To Detail
2450
BALUSTRADE
2100
To Detail
2150
STORE
SLAB SURFACE
Hospitality Grade Sealing
GROUND
41135
SHS
Galvanised Post to
Engineers Detail DECK POST
SLAB HW D Post to Engineers
Concrete Slab to FLOORING FOOTING DECK FLOORING Detail
Engineers Detail TImber Flooring to Detail Concrete Pier Footing to HWD Floor Joists to
Engineers Spec Detail
A SECTION A
1.3 1 : 50
CD4d
new build REV DESCRIPTION DATE
SECTION A JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.WALKER
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 6.1
SCALE(A3): 1 : 50
Document Set ID: 22197990
Version: 1, Version Date: 02/12/2022
Page 7
-
APPROVED PLAN
MCU22/0097
NOOSA COUNCIL
3 JANUARY 2023
A B C
A
6.1
ROOFING TRUSS
Zincalume/Galvanised Sissors Truss to
Corrugated Sheeting Engineers Specification
Bulkhead
PLASTER TRUSS
Affixed to Battens To Engineers Specification
ROOF LEVEL
44085
Ceiling
2450
SMOKEHOUSE
GROUND
41135
DECK FLOORING FLOORING SHS
HWD Floor Joists to Timber Flooring to Detail Galvanised Post to FOOTING
Detail Engineers Detail Concrete Pier Footing to
Engineers Spec
1 SECTION 1
1.3 1 : 50
CD4d
new build REV DESCRIPTION DATE
SECTION 1 JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.WALKER
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 6.2
SCALE(A3): 1 : 50
Document Set ID: 22197990
Version: 1, Version Date: 02/12/2022
Page 8
TOTAL SITE AREA 1781.0m2
LOT 1
CARPARK AREA
40.5% 722.0m²
LANDSCAPED AREA/OUTDOOR DINING
31.0% 1.85 m
552.1m2 ' 00" 6
79° 44
2880
179° 59' 40" 19.39 m
EXISTING BUILT FORM
15.5% 276.0m²
Y
BOU NDAR
PROPOSED BUILT FORM ERTY
10.8% PROP
193m²
All Planted
Trees/Shrubs to be SOFT LANDSCAPES
Native to the area & DRIVE
Listed within Noosa
PROPERTY BOUNDARY
Council PSP3
Landscaping Policy.
CARPARK
349° 4
3' 50"
9.68 m
EXISTING
GUM
RESE
179° 59' 40" 11.27 m
PROPOSED
LOT 2 GATE
ENTRY
PROP
ERTY
EXISTING STRUCTURE
OUTDOOR DINING
RVE S
BOU
HARD AND SOFT
NDAR
11000
Y
EXISTING
LANDSCAPES GUM
PROPOSED
TREE
STUCTURE
DA RY
BOUN
ERTY
PROP
-
APPROVED PLAN
T
MCU22/0097
NOOSA COUNCIL
3 JANUARY 2023
56.39 m
4' 00"
259° 4 EXISTING
STRUCTURE
EXISTIN
EXISTING STRUCTURE
LOT 7
STRUCT G
URE
EXISTING STRUCTURE
EXISTING STRUCTURE
COUNCIL ANNOTATION
The highlighted area is not
1 LANDSCAPING PLAN approved as a use area in
4.1 1 : 200
conjunction with the
development permit i.e., no
outdoor dining.
CD4d
new build REV DESCRIPTION DATE
LANDSCAPING PLAN JOB: 21.34
WALK STUDIO For: ROBIN YATES DATE: 27.10.22
DRAWN: J.WALKER
walkstudio.com.au
0409.921.601
SMOKE HOUSE
QBCC #15018637 16 Reserve St Pomona 7.1
SCALE(A3): As indicated
Document Set ID: 22197990