2. Amended Architectural Plans (Rec 27.7.26) · MCU21/0175
Plans and drawings: the text below has words only, no drawings.
Very large file (48.0 MB): may take a few minutes to open.
ANGLED SITE BOUNDARY
ANGLED SITE BOUNDARY
10000
1 2 3 4 5 6 7 8 9 10 11 12
VEGETATION
BUFFER ZONE
RL 18.928
RL 18.181
LEVEL 02
RL16.900
3000
EXISTING
LEVEL 01 BUILDING
RL13.900
5000
GROUND FLOOR
RL8.900
PEDESTRIAN PAINTED MASONRY FIBRE CEMENT METAL WIRE SERVICE LANE
SITE ELEVATION SITE - FRONT ELEVATION ACCESS CLADDING MESH SCREEN
1 Scale: 1 : 200
ANGLED SITE BOUNDARY
ANGLED SITE BOUNDARY
10000
BIO-RETENTION VEGETATION
/ LANDSCAPING BUFFER ZONE
I H G F E D C B A
SHOWROOM + 5810
UPPER LEVEL
COMMERCIAL RL 18.928 COMMERCIAL
RL 18.185
RL 16.340 LEVEL 02
RL 16.186
RL16.900
3000
LEVEL 01
RL13.900
5000
GROUND FLOOR
RL8.900
ROAD CARPARK AT FRONT MESH WIRE SCREEN PAINTED
SITE ELEVATION SITE - EASTERN ELEVATION SUPPORT VEGETATION MASONRY
2 Scale: 1 : 200
10000
12 11 10 9 8 7 6 5 4 3 2 1
ANGLED SITE BOUNDARY
AMGLED SITE BOUNDARY
VEGETATION
BUFFER ZONE LIFT + UPPER LEVEL
FIRE STAIR COMMERCIAL
RL 18.928 RL 18.305
RL 17.685
LEVEL 02 RL 16.186
RL16.900
EXISTING
3000
LEVEL 01 BUILDING
RL13.900
5000
GROUND FLOOR
RL8.900
BASEMENT
RL5.900
REFUSE STAFF CARPARK RAMP TO BASEMENT BASEMENT BELOW
SITE ELEVATION SITE - BACK ELEVATION
COLLECTION SHOWN DASHED
3 Scale: 1 : 200
10000
A B C D E F G H I
ANGLED SITE BOUNDARY
ANGLED SITE BOUNDARY
BIO-RETENTION
VEGETATION
BUFFER ZONE
RL 18.931
RL 18.305
5°
LEVEL 02
RL16.900
3000
LEVEL 01
RL13.900
5000
GROUND FLOOR
RL8.900
PAINTED METAL WALL COVERED
SITE ELEVATION SITE - WESTERN ELEVATION MASONRY CLADDING WALKWAY
4
(COLORBOND STEEL
CLADDING OR SIMILAR)
Scale: 1 : 200
Rev Description Date CLIENT PROJECT TITLE DRAWN BY CHECKED BY DATE
A Preliminary Issue 14.10.25 KW SM 17.11.2025
B Preliminary Issue 17.11.25
Suite 12, Level 2, 30 Florence St Proposed Commercial Centre SITE ELEVATIONS
Teneriffe, QLD 4005 SCALE (@ A1) PROJECT NUMBER
C Draft DA Issue 18.06.26 1 : 200 25114
D DA Issue 25.06.26 [email protected] DRAWING NUMBER REV
MK Architecture Pty Ltd Copyright. Except under whats allowed under copy right law, no part of this drawing may be reproduced or otherwise dealt with, without written permission of MK Architecture Pty Ltd.
E DA Issue 09.07.26 www.mkarchitecture.com.au
F DA Issue 16.07.26
Builder/Contractor shall verify job dimensions before any job commences. Figured dimensions take precedence over drawings and job dimensions. All shop drawings shall be submitted to the
Architect/Consultant, and manufacture shall not commence prior to return of inspected shop drawings by the Architect/Consultant. DA - 201 F
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2. Amended Architectural Plans (Rec 27.7.26).pdfRelated documentApplication case desk ↗
About this file
- File size
- 48.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.