Council archive · source document
Att 3b - Stormwater · 132003.221172.8
Attached to the e-mail Change to DA (23657 DA Duplex Dwelling) - 132003.221172.8 Attachements 132003.221172.7 - 61 Elanda St.msg.
GLOBAL TESTING THE ONLY NAME IN SOILS QBCC Licence No. 1018403 PH : 07 54 740 900 3/53 Gateway Drive, Noosaville 4566 JOB NUMBER 15/1054 SITE CLASSIFICATION REPORT CLIENT ZIGANNAIRE PTY LTD SITE LOCATION | PROPOSED DUPLEX, 61 ELANDA STREET, SUNSHINE BEACH REPORT DATE _| 21/10/2015 INTRODUCTION The purpose of this report is to classify the subject allotment in accordance with Australian Standard 2870 - 2011 ‘Residential Slabs and Footings'. From this classification a footing system can be recommended for the structure so as to allow adequate performance of the footings under the soil conditions determined at the site. Trees: There are several small to large trees on and adjacent to the proposed site. Global Testing recommends an experienced arborist be commissioned to quantify the existing size, location, predicted maximum height and type of these trees to aid in the design process. It is the responsibility of the designing engineer to apply the principals of AS2870-2011 Appendix H "Guide to Design of Footings for Trees" . The classification herein excludes the effect of trees on the site. Please note: The site has an existing residence which is to be removed. SITE DESCRIPTION Type of Allotment Residential Vegetation (Building Envelope) Grassed/Scattered small to large sized mature trees Vegetation (Allotment) Grassed/Scattered small to large sized mature trees Road Status Sealed Slope 7-9% to the Rear Surface Water will Drain Towards Rear Will Surface water from adjoining May allotments traverse this site Does the site have any watercourses No Surrounding Allotments Left Existing Residence Right Existing Residence Rear Existing Residence Depth to Weathered Rock N/a Depth to Water Table N/a SITE CLASSIFICATION AND TARGET STRATA Based on the findings of the site investigation, the classification of the site is considered to conform to:- CLASS “ P ” (Due to poor bearing capacity, the presence of trees and the removal of an existing residence - Piering Required) (PLEASE NOTE: If not for the poor bearing capacity and trees encountered and the removal of an existing residence, this site would have the characteristics of an 'S' site) in accordance with Australian Standard 2870 - 2011, 'Residential Slabs and Footings, Construction’.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 3b - Stormwater.pdfRelated documentApplication case desk ↗
About this file
- File size
- 8.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.