aqua

Debbie Munro
Ziganairre Pty Ltd

by email
3 August 2017
61 ELANDA STREET, SUNSHINE BEACH — STORMATER QUANTITY ASSESSMENT

Dear Debbie,

Aqualntel have been commissioned by Ziganairre Pty Ltd to undertake a stormwater quantity assessment to
address an Information Request by Noosa Shire Council dated 13 July 2017 (OPW17/0225) for the proposed
development at 61 Elanda Street, Sunshine Beach. During this investigation discussion with Noosa Council were
undertaken in order to seek clarification on the intent of the development conditions and on the status of the
legal Point of Discharge for the site. It was advised that stormwater could be discharged to the street as long as
the maximum rate at which it was discharged is limited to the requirements of the conditions and that if runoff
cannot be directed to the street then stormwater must be infiltrated underground in order to minimise any
potential issues with stormwater flows increasing into neighbouring properties as a result of the development.

SITE AND CATCHMENT

The proposed site is located at 61 Elanda Street, Sunshine Beach. An existing residence is located on the
western portion of the site. Currently stormwater is discharged to the ground within the site.

The total site area is 505 m’ and the site falls to the east at a grade of approximately 12.5%. Stormwater runoff
would currently flow overland towards the rear of the property at the South East corner of the site. No
evidence of a formalised stormwater infiltration system has been located. Total catchment area assessed is
600m? which includes the site and rear falling verge.

Of this catchment 90m? of roof will be discharged to the Elanda Street. The development conditions for the site
specify that a maximum flow of 25L/s at any one location is to be discharged to the road, of which it understood
that the development complies with this condition.

The catchment is shown below in Figure 1.

m: 0439 119 890 t: +7 5414 7185

e: [email protected]
Ww: www.aquaintel.com.au

Used in these records

About this file

File size
8.8 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Att 3b - Stormwater.pdf · 8.8 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.