Council archive · source document
04/5743 - Change to development application [As Published] · 132004.5743.02
Very large file (14.8 MB): the original may take a few minutes to open or download. The page text below is quick to read.
BCA BNTSYeRG Checklist - Applications Involving Land
hom Development & Land Use Sections
IDAS APPLICATION
This checklist should be used for any IDAS application. Please check each of the following items before accepting an
application at the counter.
1. APPLICATION FORMS -
4.1. Form’ PartA {
1.1.1. Ensure that the form is fully completed.
1.1.2 In the case of an MCU or Op Works below the high-water mark, owners consent is required. rr
1.1.2.1 If there are multiple owners, the consent of each owner is required.
1.1.2.2 _ If the owner of the land is a company, either ACN No. or Company Seal required.
1.2 Form’ Part B-O Supporting Information
1.1.2 Ensure that for each box checked on Form A, the relevant additional Forms B-O are attached. C]
LILI
1.1.2.1. Ensure that each of Forms B-O which are attached are fully completed. C
2. REFERRAL INFORMATION
2.1 Ensure that items 1-23 have been checked and/or completed with regard to referrals. CT
3. | ENVIRONMENTALLY RELEVANT ACTIVITIES
3.1 Ensure that Part G is completed if EPA referral is required.
3.2. Where EPA is delegated to Council (see * in ERA checklist), ensure that the correct application
fee is paid and recorded on the application. .
4. _ FORM 2 - REQUEST TO CHANGE APPROVAL
4.1 Ensure that items 1-28 have been checked and/or completed including information regarding [TI
applicant details and owners consent. Lv | J
5. PLANS a .
5.1 Ensure that at least 6 sets of the Plan of Development (5 for Reconfiguration and Operational [4 |
Works) accompanies the application. In addition ensure that each set is complete.
5.2 Ensure that 1 of the copies of the Plan of Development is in an A3 or A4 format and is
unbound.
6. SUPPORTING INFORMATION . .
6.1 Ensure that at least 6 copies of any report accompanies the application (5 for Reconfiguration
and Operational Works). If the application is accompanied by a covering letter, ensure that it is £
capable of reproduction. [74]
6.2 In the case of reports, ensure that 1 of the copies is in an A3 or A4 format and is unbound.
7. FEE . .
7.1. Ensure that the application fee, as determined from the Council's adopted scale of fees,
accompanies the application or has been paid.
7.2 Ensure that the fee which has been paid is recorded on the application form. S/S
Receiving Officer
Having completed this form and accepted the application, please deliver both to the following IDAS Application Receiving
trays:-
* If the application is for a Material Change of Use exclusively -AOP1’s desk in the Land Use Section.
« Ifthe application is for an Material Change of Use & Reconfiguration - AOP1's desk in the Land Use Section.
¢ If the application is for Operational Works (for parking, access, sewerage or drainage) exclusively — AOD2 in the
Land Development Section.
¢ Inall other circumstances — AOP1’s desk in the Land Use Section.
Please DO NOT leave the application at the counter and DO NOT deliver the application to Records.
SEP# g.\ant\forms\application checklist.doc
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 12 pages
Page 2
Form 2, Version 3.3, 29 May 2006
Request to change an
existing approval
Description of land
Allland the subject of the application must be
identified.
Advice for completing Q1
A description of the land is not required in
relation to a mobile or temporary
environmentally relevant activity.
Advice for completin and Q3
Provide the information from the existing
approval that is the subject of this request for
change
Advice for completing Q4
Q4 applies if development is proposed in a
water body or watercourse
Advice for completing Q5
Most land can be identified by a lot on plan
description. These details can be obtained from
titte documents or through the local
government
However, if the land on which the development
is proposed does not have a tot on plan
description (i.e. the development is proposed in
a water body or watercourse) —
(i) provide the lot on plan description for the
adjoining/adjacent land; or
(ii) provide GPS coordinates where there is no
adjoining/adjacent land (i.e. in Moreton
Bay).
Advice for complstin:
Q9 does not apply if the development is
proposed within a water body or watercourse
Advice for completing Q10
Q10 onty applies if development is proposed
within a local goverment area.
Tidal areas are below high water mark and are
not within a local govemment’s area.
Advice for completing Q11
Q11 only appties if development is proposed on
strategic port land or a strategic port land tidal
area.
For more information refer to Guide 14
Development on strategic port land
Note: These details will be included in the
original decision notice for the approval you
now wish to modify.
10.
11,
Street address ¢ncluding house number, street name, suburbVlocality name & postcode) (if applicable)
[\@ Poca as Rest, SOFIE Beaeth 4564 |
Number on existing development permit or 3. Date issued:
preliminary approval sought to be changed:
[Zees /S745 | [Z26.N. ob |
+
Name of water body or watercourse, within which the development is proposed: (if appiicable)
ZS
Lot on plan description (eg. Lot 123 on RP 4567)/GPS coordinates
[LET IS coe peomer] AaTe bis
The above description is for: (tick appiicable box)
(441i) the land on which the development is proposed; or
C1 (ii) the land adjoining the water body or watercourse, within which the development is
proposed; or
Lili) the water body or watercourse.
Shop / tenancy number: (if appficable) 8. Storey / level: (if applicable)
[ w/e [ Je.
Total area of land: (m?/ha)
[ 728-4 em |
Local government area in which the land is situated (eg. Brisbane, Esk, Hervey Bay, Woocoo etc.) {if
applicable)
Hilcose 21 URE cooPe1L—
Port authority for the strategic port land or strategic port land tidal area on which the
development is proposed (eg. Port of Brisbane, Port of Townsville) (if applicable)
[w/a . |
Page 3
INTEGRATED PLANNING ACT 1997
Form 2, Version 3.3, 29 May 2006
Applicant details 12. Name:
Clearly identify who is making the application. | Parawicemees Pb
The applicant need not be the owner of the
tend. 13. Postal address:
When signing and lodging this application rio. Sone ike
The applicant is responsible for ensuring the | Bot 217 CS “+567 |
information provided is correct. The . . .
assessment manager, any referral agency and | 14. Signature: 15. Date:
the Chief Executive (where applicable) will rely
on this information when assessing and L 4 4
deciding the application. . : 25-05-07}
ifthe applicant is a company
A contact person must be shown. All 16. Contact person:
correspondence will be mailed to this address.
Poncencewn [A tan Rolbentson |
17. Telephone number: 18. Mobile number: (if appicabie)
| S442 4644 ] [oar 7386 8295 |
19, Fax number: {if applicable) 20. Email address: (if applicable)
[Saaz ANG lrtanc Dalaasimeleie + Gorn Ga |
Land owner/s consent (if applicable) 21. Land owner's consent:
Section 3.5.24(3) of the IPA requires that the ‘
land owner's consent must be provided ifthe Name in Full fo Signature { Date
person making the request to change an Fy - J
existing approval is not the land owner. ti) Dynern iS Cofhes PL Ss.05 of
For information about land owners refer to
Guide 1 Making an IDAS development (ii) 29 05.04
application. SAT C7”
Land owner’s consent is not required for a (iii)
mobile or temporary ERA. AEN * 63 101748 77b.
lf an owner has signed this form as i)
applicant, their signature is not required again (Ww) Aiv - /o)} 7 40 7 7 &.
in this section.
If there are multiple owners, the consent of
each owner is required.
Resource entitlement (if applicable) 22. At the time of the request, would a development application for the approval have required
Sections 3.5.22(4) & (5), 3.5.24(3B) & (3C), evidence of resource entitlement?
and 3.5.33(3B) & (3C) of the PA may require
the written agreement of a resource manager if [No ~ goto Q24 0 YES - go to 023
ao eaeet when the acest was made __|23- Is this request accompanied by the written agreement of the chief executive from whom the
development application for the approval would evidence is required? (tick the applicable box)
have required evidence of resource entitlement CI NO - the written agreement of the chief executive must accompany this request
under section 3.2.1(5) of the IPA. ia YES
Nature of the request 24. This request is for.
Any person may request to modify an existing (An extension of the relevant period for the development approval (s 3.5.22)
approval. ngs
[46 change or cancet conditions (s 3.5.33)
(1 To change the development approval (other than a change of a condition) (s 3.5.24)
CD Achange to conditions of a rezoning approval given under the P&E Act (s 6 1.354)
25. Provide details of, & justification for, the proposed modification
YsEre te Adhere LF ae.
Concurrence agencies 26. Did the previous application involve concurrence agencies or building referral agencies?
Under $3.5.22(1)(a) & 3.5.24(1)(a) of IPA, a Mno
copy of this request must be forwarded to each
concurrence agency for the previous (YES - fist the concurrence agencies who have been sent a copy of the request for modification
application prior to lodgement of this form with 7
the assessment manager. (i)
Note: “No” will always apply to a request to (ii)
change conditions of a rezoning approval given ae
under the P&E Act. (ii
Page 4
INTEGRATED PLANNING ACT 1997
Plans and documents
An application should be accompanied by
details to support the proposal & enable the
assessment manager, referral agencies and
any person viewing the appfication during
public scrutiny or public notification to
understand the scope of the proposal and any
potentiat impact.
27. Plans/drawings/reports accompanying this application:
Form 2, Version 3.3, 29 May 2006
Plan / Drawing / Report Number
Titte
Date
RETZR—-NO peer
Eseusee-
OFFICE USE ONLY {applicable to assessment managen
DATE RECEIVED
REFERENCE NUMBER/S
Page 5
Shane Adamson Manager - Land Use Noosa Council PO Box 141 Tewantin QLD 4565 22nd May 2007 Dear Shane, | refer to the Decision Notice handed down by Noosa Council on the 29th of November 2006 with regard to Fite No: 2004/5743; being Lots 0,1,2 & 3 GTP 615, County of March, Parish of Weyba. The following letter is constructed to support and explain reasons for seven changes to this current Decision Notice. Drawings related to the Changes Application will be mast easily understood if read in conjunction with the abovementioned Decision Notice’s approved drawings, numbered 61.04.02, 61.04.03, 61.04.05 and 61.04.06. These will be upgraded and superseded by drawing numbers 61.04.52, 61.04.53, 61.04.54 and 61.04.55 respectively. These upgraded drawings represent graphical interpretations of the proposed changes; Changes A to G are shown on these drawings. Below is a written description of these proposed changes; Change A Description of Change - Raising Basernent Floor Level from RL 33.385 to RL 34.576. Reason for Change - The Town Planning Scheme by which the existing approval has been assessed, determined that a basement region did not constitute a storey if it was into the ground at it lowest point by a distance not less than 1200mm. This lowest point occurs at the point in the basement level furthest away frorn the vehicle entry side. This in turn means that the point of greatest excavation is at the base of the driveway. This makes the driveway reasonably steep although still achievable by Australian Standards. The raising of the basement level will decrease the steepness of this primary vehicle, and at times, pedestrian, access and egress. Raising of the basement level will assist with the required gravity discharging rainwater from this level. Raising the level will also reduce the impact of excavation and its effect on neighbouring properties existing structures, and will assist in the reduction of physical and mechanical resources. Outcome - The other existing floor levels, total building height. and the mass of the building above ground level will not be changed. Change B Description of Change - New stair arrangement to front of Unit J. Reason for Change : New Outcome - New architecture « interiors « sustainablebuildingdesign ° planningdevelopmentstrategies willfranklindesign * 5 1marystreetnoosavilleqid4566 * p.o.box1354noosaheadsqld4567 tel0754743237 ¢ fax0754741020 © [email protected]
Page 6
Change C Description of Change: Additional visitor car parking. Reason for Change : New Outcome : New Change D Description of Change : New stair to side of building and top of stair from basement Reason for Change - New Outcome : New Change E Description of Change. New arrangement of pool to Unit | Reason for Change: New Outcome : New Change F Oescription of Change: Replacement of balustrading Reason for Change : New Outcome New Change G Description of Change : Stair from Unit 2 - level | to pool! level. Reason For Change: Outcome : Kind Regards, Will Franklin architecture interiors « sustainablebuildingdesign ¢ planningdevelopmentstrategies willfranklindesign ¢ 5 imarystreetnoosavilleqid4566 « p.o.box 1354noosaheadsqid4567 telo754743237 * fax0754741020 * [email protected]
Page 7
V cSo'p0'T9 voto tf
“ON Buymeiq ON gor
- ne*woo'uB|sepulpueyyim@pinep
| UWos}eyA plea
YORE MEU eee aa SRR ‘xoudde (p'Z¢ 74) [@A9] @Anejal quay :a}ou
Ne Woo Uus|sepu|PUEYIIIMBIIIM eee 5 ee i i : a BU esp ier aa spe :
UIPIUELY TIM
WOOO ZOoOS4IS sel/Bnop
i
cae.
\ Zn
a
( a
\
WOES S| Su! Aszepun wmoEes Zz]! Sul Aa
, “2 Baste hes eet. : ; Bupyed 125 Joys, MeN o ‘ Peaipract
| ex ie ey ERTS Jood jo yusweGuewees ; 3 ae 5 Bue \ : ; fea Gonup JED JOYS! MON
*PIOs!q 0} 4100p Wood Guay} ‘z [ana] ‘p 3}UN
H39NVHO
| 198] Spuod Uo}}Da}J8J Jo azIs Ul UOONpEL
9 39NVHO
jueweseq Wods 112} 0} Bulpuel 4je}s Meu
4 SONVHO
useios ;yBj9y4
1105 Uji Bulpesysnjeg jo ,ueweoe|des
3 39NVHO
*sBUIpiing Jo apis 0} 4/e}s Mau :
d 39NVHO Te) : g ebueyD
yaedued 10}S1A |BUOH|Ppe : 7
2 39NVHO
{ 31UN 0} jUsWaBUeLe 113s UIs Mau
§ 3ONVHO
JeA9] jUsWeseg Joy Bulsjed 4 eBueyo Caan ae ig . as
V3ONVHO Snes ee ie 7a 5 Beles é 4 sBueyo Sei
(2 Uoppued e2}}0N Uo}s}9eq 0} 4424) : Si! é A : oe ie palin s eal use OPIS $S9908 0} JIEIS MON
Z UN 0} 3noAe| jood jo juewWeBuELe-2)
pur uojediiddy seBuey 405 sije38q 20-S0-2Z v
gy ebueyo
i
1
fe
“VOQSESY YUM soueplos9e
Lu Jo}B4edo jo1jU09 ysad paoued & Aq Buipjing ey) Jo ej!) ey) noyBnosyy
NO paujes ele (Asesseoeu se UoHBOIpele snjd) suojoedsu! jenuue joy) pue
Ulpwel sieieg jeo|Wsy Aue yey) ‘dn pling j!os 40 spa uapyeb jo
Je9j9 jay exe sJaliJeg jeoisAyd Aue yeu} ensue |JeYs S/JBUMO BY) eyeaLeY |.
“ypnoidde j)uued Bupjing ey} Jo }uswabpo| jo ey,
84} JB 40 0} JOU JeyJ80 pasusd)) 40 juewWUenOb |e90) ey} 0} pasinpe eq |!eys
UBL UOREUUOJU! Siy | 4O}EVEdO JoujUOD jSad pEsusdlj E Ypi/A UOYEYNSUOD LYE
‘Aluo Jepying Joypue sisumo aly Aq pauluuajep eq |Jeys UoHIejOId Jo poyjewu
esioeld 8l1 “| QQ9eSW YIM SoUEpIoNNe U! SJalLJeq JeolwWeYyo Jo/pue jeoishyd
panoidde Aq sejjuie) UesueLe}qns Wo, pajoa}oud eq jjeys Bulpjing ey,
UoRoe}Old eYUe),
‘SpJepUE}S UEI|EYSNy JUBAG|@J pue Suo||eiNBed YOR YIM A\dwiCO
0} pal|e}sul 8q 0} suBis uo}eyonssed pue uoyonysuco =je6 pue Buious) joo4
“SplepUe}S Uel/eqsny JUBAR|al
pue suoyeinBel yo yim Ajduioo ojuo}on4suo9 pue Uo}e|/e}su! Buipeysnjeg
“SpJBpUEIS
ueyegsny 3 suoyeinBas ¥OR JUeAe|a! YM Aldulod 0} $100q] B SMOPUINY |I\7
‘sjuawasinbel “y'9'g pue
SPJEPUE}S UB|EASNY Yilm B9UEPoN9e UI \NO palLieD eq Oo} UOHOBjOId EWE),
"uoqeoyloeds siesnjoejnuew Jad se paljejsul eq 0} sassniy
“uolJBoyioads sieunjogjnuew Jad se paljdde eq 0} jno-yGnosy) Buyoosdiayey,
“suotjeinBeu yOg YIM S9Uep1ONIe UI palje}SU! 8q 0} SlO}Da}ap @OWS
“eINPeYOS 100g PUB MOPLI))\ O} Jey
*sjusweyinba! uBlsep pue suolejnBel juno,
1290] Yj e2ueps0098 Ul pejon4}suod 8q 0} 49eqAB| PUB JeA0-sso10 AEMEALG
ynoAe| pue uBisep Buiquinid 40) seeuiBuz o1nespA} 0} Je}oy4
“WOHEOYUEpI jesN}onUS Jo} UOHE|VELUNDOP BuyeEUIBUR 0} J8j9y
"|9N@| JOOY PaYsIUy S174
"J8N9| qejs Paysiuy SI Ty
“wojjons}Su09 Joy Joa YOuy
84 Aq panss! |l}un sesodind uorjons}suod Jo} pesn eq jou jje4ys sHuIMe/G
“sBulmesp asely} 9/298 OU OG
(eqs uj uoponped)
SdS've Idd 9 See'ee 144
WoJ) pas|ed |eA9] JuUsWeseg
y ebueyo
Ce Ser rr rue ee i ee me
wzsi-zZe Sul Arepuncg
wuzSLce eur Arepunog
pu S101 jj2 AUeA pue suoIsUeUup jje Alien pue x9eYO |I2YS JepIING Sty
S9}ON [e1eUeS
*sjueuieuinba! jlounod Jed se papiAoid oq 0} 612 SUB} J8}BMUIe) pa}ons}suCo
pue Ajddns 18,2 um} Buysixe s,!9UNod 0} pajdeuUCD aq J/EYS OUIS Ol)
ey “sjuawiauinbas »g spsepue}s j!9UNOD Uj|M BOUBPJ09e UI pajonsjsuo pue
swe|sfs Buyeinoyed abesemes Buljsixa sj!on09 0} pa|euUod oq ||BYS a}!s OY
*sjuaweyinbed
Aiddng 48)2\\ pue semeg ‘Ye}eMUUO}S z 3 oh a SuPe|] sejbnop
s “youelg jsiy ey soni pue s9}20y 4 o
4 Jo Jo7INO oy Jo UH}, Ui4jWn deg yeaY e YM PAH 8q /BYS WE}SAS JO}EM JOH F co) 5 :
“sedwep Buisojo sJas & yjuA payy @q 0} seoeds peuojpuco o suey \sNeYXE |Iy f ; 5 (LE°ZE Td) sue] se|Bnop 0} pay AyAes6 s)
's8e)6 ,uaei610n3, Uo}Bupiig YyA pany 9q 0} peze|6 exsym pue me ele (9ZS'7E 1H) JUeWAase ‘ou! eBeuleJp os
‘SIEM PELUEY JOUB}xE jIe O} SEQ IIEM SLY
“SIEM Paes) JOUB}x@ |Ie 0} 7-44 a|qeauuied snodey,
“aoeds J00J ul paije}su! aq o} s}}eq LoyBINsU! Bulyso joOMA\Og GZY
“Buyoos mojaq paije}sul 9q 0} Uoye|NsU) UOD\}UY WLIOg
sjuewesinbey Aoualoiyj3 AB Jeu
“Aiesseoeu }! peoejde, pue pauigjuiew
@q 0} ae saoua} Alepunog Auedoid ‘uoljonsjsuo9 Jo esinco sy
aden unos
‘Aq pauinbes eq Aew uejd juewieBeueWw a}seM B 'UO!OWEp Jo BOUE}SU! BY} U}
‘ZL ON MBq [2907 syoUNCD
[290] 84} yjiM Ajdwico |jeys sjueuidinbs jeoluBYoeW Woy UOISSIWe BSION
*wounoo Aq peyinbes
@q Aew jo.juoo jo spoyjeui ayy) Buijtejep Ueld y ‘a}Is 84) Guinea] Woy podxe
JUSWIPas pUk UOISO/e }UsAaid 0} PAMOIjO} eq 0} BJE SBINSBALU |O.4UOD BIS
[OAUOD SUIS
Page 8
V es’p0'T9 po'To'tf
‘ON Bumelg ON gor
Ne wWod'Us|SapUlP{UEdJ||/M@PIAeP
uos}e/M PIAeG
uonejuewinoog
NE" Woo 'UBIsapulpyUEdI|/M@|IIM
UpPUEdy TIM
Joubiseq yoelodd
ele9s
Ps ne; woo "UB \sapulp 124
SOZOF ¥L¥S 10 «. *.
rece verS LO?
$F
*PIOJIq 0} JOOP Woos Bujaly 'z JeAe) ‘} yun
H3SNVHO
| 1843] Spuod UoHdaIJaJ Jo az! U! UOONpsL
9 39NVHO
jueweseg Woy 1}e}s 0} Bupuey s}e}s Meu
A 3ONVHO
usalos 7yBjoy
11T} YM Bulpesjsnjeg jo pusWeoR|des
| 3 S9ONVHO
*sBUIp|INg JO aps 0} 41838 Meu
G 39NVHO
yuedied 10})S1A |BUOR| PPE
9 3ONVHO
} UN 0} juaWeBUeWe 4123s }UO1) Mau
: § 3ONVHO
Je Aa] }JUBWEsE Joy Bulsies
V3SNVHO
(Z UoR|PUOD B2RON UO]s199q 0} 18484)
Z HUN 0} jnOAe] jood jo yusWaBUeLe-31
pur uojeoiddy saBueyo Joy syieieq LosozzZ
"LOSQESY YIM souepIoDe
Ul Jo}BJedo josjuo9 jsad paousal) @ Aq Buipjing ay} jo 841) ey) jnoyBnosyy
yno paleo eye (AJesseoeu Se Uol}esIpeJe snjd) suojosdsu! jenuue Jey) pue
I eg jeoiwey Aue ey) Os JO speq uspseb yo
Jeajo }dey eue sielsseg |eoisAyd Aue }Bu) einsue |/2Ys S/jeUMO Bly JeyBaley|
“yeaoidde j1uued Buipjing sy) Jo juswabipo| jo euy,
1} }2 JO 0} JOlNd Jey1]489 pasuedi JO }UBWLUEAOB j290) 84} 0} Pesinpe aq ||EUS
BY} UoyeWLJOJU! Siy | O}eJedo jos)U09 Sed pasued|| & YjIM UOE}INsUOD Jaye
Ajuo sapling so/pue sisumo ayy Ag pauluuejep eq |jeys Uoyoa}Oud Jo poyjew.
asioeid eli! "| QQ9RSYy Uj! SUepJO00B Ul SJal/Jeq je91WeY9 Jo/pue jeaisKyd
penoidde Aq sajjuuia} UBaueLIe}Gns Woy pajoajoid aq |jeys Buipjing ey,
UoROBIO EYL!
"spJepue|s snl JUBAB|s! pue SuO}EINBad YOR YM Ajdwoo
©} paije}sul eq 0} suBls UoWe}ONSsed pue UOHINjsUOD eje6 pue Bulouey joo4
“SPIBPUE}S Uelje4sNy JUEAE|eL
pue suojeinBes yog yj Ajduoo ojuoHonsjsuo9 pue Uo_e}e}sUI Buipejsnjeg
“SPIBPURIS
ueyegsny 3 suopeinBos ¥OR JUEAa|a! YyIM Aidulcd 0} s100q @ SMOPUIAA IY
‘sjueweunbed “y'9'g pus
SPIEPUE}S UBI|ENSNy YIM BOUEPs0998 UI jno PaLLIeD aq O}
‘uoyeoyloeds suesnjoejnuew Jed se palje}su! eq 0} sassniy
“uoleayioads syesnjorjnuew Jed se psidde aq 0} jno-yBnosy Buyoosdayeny
*suolj2inBe YOR Yj S9UEPONIe Ul palje}SU! 6q O} SIO}9B}EP ByOWS,
“@|NPAYOS JOOq PUB MOPUI/Y O} J8}9y
*sjuawedinbe! uBisep pue suo}e( i
1290] YIM BoUEPsCO9e Ul pajonujsudD eq 0} yoBqAR| PUe JBAO-Sso19 ABMAALIG)
\noAe| pue uBisep Buiquinjd Jo) JoauiBuz oynespA} O} Je}94
"UONPO'N}USP! |esN}ONY}s 40} UORB}UaWUNDOP HuUesUIBUZ 0} J9}oy4
“[@A9| JOOY PaYsiuy S174
"J@N8| GEIS paysiuy Si Ty
“yoOn}SU09 Jo} joBy!YONYy
ely Aq penssi jjjun sesodind uoj}nyjsuo9 Jo} pasn eq jou jjeys sSumeiq
payiyauy 8y} 0} suOIss|LuO
| pue siowe je Aue pue suOISUaLUIp |e AeA PUB y9BY9 IJeYs Japling ey)
SO}ON [BeUIeS)
*sueweuinbel jlounos Jed se papiaoid aq 0} eye Sue} JeyeMules pejonsjsUGD
od pue Aiddns se}em UMo} Bugsixe S,oun09 0} pajsuuod aq JUS B}IS By]
"s]ueWeuinbed 9 SpJepUE}s |!DUNCD YIM BOURPIOIE U Pajons|suoo pue
swe}shs Buyeinoye, eBesemas Guljsixe s,jiono9 0} pajgauuod 8q ||BYs o}!S SY
*sjuswelinbas
lounoo yim BoURpJ0998 U! Jo pasodsip aq 0} Ja}EMULO}S BOBUNS g JOO
Ajddng Jee) pue James ‘“e}BAKLUO}S
“YOUBIG {S14 84} B/OJeq ue Je}B94
‘4g JO J9H|NO OY) Jo Wy UIYIMA deg JeaY & YIM PAHY aq |Je4S Wa}Sks 18)EM JOH
‘sedwep Buisojo sjas 2 yy payy eq 0} Sededs peuOyIPUOD O} SUBJ SNEYXE ||\y
GMM PaHy 6g OF ‘1am pur
UOWeH}|YUl JIB JOUSB, 0} |BBS B YIM Pay 6G O} SMOPUIA Q SIOOP }ELIA}XE ||
‘SIJEM PALEY JOUD}x@ [IB 0} SEQ [EM GY
“SIEM PALEY JOLN}Xe ||2 O} 71-4 jqeauuued nodep,
“eoeds J001 U! palje}sul aq o} seq UoHeiNsU! Bul}i69 jooMAjod GZ
“Buyoos mojsq palje}Su! 6q 0} Uo}}e|NsU| UCOHUY WLIDS
s]ueWeJinbey Aoueloiyj3 ABJeuR
“Aiessageu j! peoeides pue paulejuiew
@q 0} eJ2 sequa} Alepunog Ayedoid ‘uolnsjsuo9 Jo ssinao at
Aq pauinbai eq Aew uejd juswebeuew ejsem e ‘uo}!oWep Jo soUR}su! oy} Uj
Zh ON Me [2907] Sunoco
Jeo] 84) uj Aidwioo jjeys sjuetudinbs jeoiueyoau Woy UOISsiWe esioN
*younos Aq pauinbes
8q Agus joujuo9 Jo spoyjew oy} Buljjejep uEjd y “e}!s oy} BuInee| Woy yodxe
JU@WIPAS PUB UOISOJS JUSAeIC 0} PSMOI|O} Bq 0} SJE SeINSESL |O,UOD BIIS
[OAUOD BUS
ZEL°2e Sul Arepunog
se|bnop
‘Ze Sully Asepunog
|
|
|
1
|
|
wmzesLi-zZe eur Arepuncg
Z2eL2e oul Asepunog
e9°Z2e Sur Asepunog
WOES’ Zz Sul] Asepuncg
|
|
wuzeSLl-cEe oul Arepunog
|
g ebueyo
Page 9
Site Control
Site control measures are to be followed to prevent erosion and sediment
export from leaving the site. A plan detailing the methods of control may be
required by council,
Noise emission from mechanical equipments shall comply with the local
council's Local Law No. 12.
In the instance of demolition, a waste management plan may be required by
council.
During the course of construction, property boundary fences are to be
maintained and replaced if necessary.
Energy Efficiency Requirements
po 50mm Anticon insulation to be installed below roofing.
eee he setae ee R2.5 Polywoo! ceiling insulation batts to be installed in roof space.
ven Vapour permeable RFL to all exterior framed walls.
Bs A Nf er sete man ey ase ne ene mane ae ee ee ae Ra Meet AY orcas fon oh ea brag tee} S dae au eer Mpg at sg gra el Scat nah ae MMM SS SSS Ly een itp Cy Pe tS ca Whee geist pa aa TEP UN Eps gs Say ARDS qi Vg 1A ae a ae Rae ne eee ee cece SR SS R15 wall batts to all exterior framed walls.
Te rats tr a eR TO eT eS a ESE ee eee and where glazed to be fitted with Pilkington ‘Evergreen’ glass.
Sea ea ea ee Ser peered ere ae AN ee ae a a = All exhaust fans to conditioned spaces to be fitted with a self closing damper.
iene Hot water system shall be fitted with a heat trap within 1m of the outlet of the
ny ee sme Mm ten eS AN Bs heater and before the first branch.
office
_— al gs Stormwater, Sewer and Water Supply
wii = ae ee e 10° Si Roof & surface stormwater to be disposed of in accordance with council
2,832
Ne eal —— fequirements.
eeu chants Ss SA aa The site shall be connected to coucil's existing sewerage reticulating systems
Se ee c a jp and constructed in accordance with council standards & requirements. ——
ay aa ear a 6 ea soa és re The site shall be connected to council's existing town water supply and |
és ay S| constructed rainwater tanks are to be provided as per council requirements.
700 N
K
|
SI ‘ony living balcony General Notes
)
The builder shall check and verify all dimensions and verify all errors and
|
—= living Fi balcony el
anil a ee ase Ss | : Do not scale these drawings.
a == a a ae, = ———— aa ae ae eee ea e Drawings shall not be used for construction purposes until issued by the
ya aia ng ER ; io 3 1s él Architect for construction.
4 & RLis finished slab level.
a entry FL is finished floor level.
3 b 3 i 6 Refer fo Engineering documentation for structural identification.
entry d Fa Ci alcon bed ens 'd media room 8 Refer to Hydraulic Engineer for plumbing design and layout.
8 ol Driveway cross-over and layback to be constructed in accordance with local
wa i = JAS Council regulations and design requirements.
Z LETS or pe Refer to Window and Door Schedule.
Smoke detectors to be installed in accordance with BCA regulations.
|
\
'
200.)
0
Waterproofing through-out to be applied as per manufacturers specification.
Trusses {o be installed as per manufacturers specification.
Termite protection to be carried out in accordance with Australian Standards
and B.C.A. requirements.
All Windows & Doors to comply with relevant BCA regulations & Australian
Standards.
Balustrading installation and constructionto comply with BCA regulations and
relevant Australian Standards.
Pool fencing and gate construction and ressucitation signs {o be installed to
comply with BCA regulations and relevant Australian Standards.
00%,
7
2
change A
proposed new basement
floor level
change A
proposed new basement
floor level
483 | 21
ey
carport Ui) carport
carpart
300
Termite Protection
The building shall be protected from subterranean termites by approved
physical and/or chemical barriers in accordance with AS3660.1. The precise
method of protection shall be determined by the owners and/or builder only
after consultation with a licensed pest control operator. This information then
shall be advised to the local government or licensed certifier prior to or at the
time of lodgement of the building permit approval.
Thereafter the owner/s shall ensure that any physical barriers are kept clear
of garden beds or st up, that any chemical barriers remain undisturbed!
and that annual i ions (plus eradication as necessary) are carried out |
throughout the life of the building by a licenced pest control operator in
accordance with AS3660.1.
current level shown dotted
previously approved
section d
section A
A 22-05-07 Details for Changes Application and |
re-arrangement of pool layout to unit 2
(refer to Decision Notice Condition 7)
CHANGE A
raising RL of basement level
CHANGE B
eee new front stair arrangement to unit 4
51-5 111 sa ei es Sl CHANGE C
o aa ane additional visitor carpark
SS re CHANGE D
new stair to side of buildings.
CHANGE E
NS replacement of balustrading with full
height screen
CHANGE F |
new stair landing to stair from basement
CHANGE G
reduction In size of reflection ponds level 1
Z Sas ee CHANGE H
a unit 4, level 2, living room door to bifold.
aI
12 mht line
it
BT
mn
ini
2.400,
PE
nnn
iii)
balcony
: , NV idindesign.com‘au ‘f
balcony
ill
ZA
change A
proposed new basement
change A
Proposed new basement
floor level
current level shown dotted
previously approved
SS
SS
section B
Will Franklin
[email protected]
Documentation
David Watson |
[email protected]
Job No
JJ.61.04
Page 10
3,000
3,000
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
translucent balustrading glass
conc block - rendered
acrylic textured finish
boundary line
fibre cement- rendered
acrylic textured finish
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
random battens sizes & spaces
th vertical supports
conc block - rendéred 7)
acrylic textured finish
east elevation
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
fibre cement- rendered
acrylic textured finish
42 metre height line
corrugated colorbond roof sheeting
colorbond guttering & RWPS
colour TBA
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
random battens sizes & spaces
with vertical supports _UtL3 FFL 44.460
U3 FFL 43.780
FFL 43.260 u2L3
San Seas conc block - rendered
acrylic textured finish
conc jblock - rendered
acrylic textured finish
Una FFL 4.se0
FFL 40.260 U2-L2
see
FFL 37.260
Lo = = Founidary tine
{ ement walls
aaa new baserhent reinforced concrete.off form
floor level '
current level shown dotted
previously approved
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
north elevation
Douglas Street
random battens sizes & spaces
with vertical supports
conc block - rendered
14 acrylic textured finish
change E
change D
2,800
3,000
4,575
change A
proposed new basement
floor level
change E
aluminium screen to future detail
alum. framed louvre window
150 blades - mix, clear, translucent
& solid (aluminium)
corrugated colorbond roof sheeting
colorbond guttering & RWPS
colour TBA
cone block - rendered
acrylic textured finish |
FeLAAA@ US
FeLAa7e0 ULL
concrete block -rendered & painted
random groove strips
FFL 40,960
Ut-L2
1
new basement -
1
:
:
i
fibre cement- rendered
acrylic textured finish
corrugated colorbond roof sheeting
colorbond guttering & RWPS
colour TBA
conc block - rendered
acrylic textured finish
concrete block -rendered & painted
random groove strips
fibre cement- rendered
acrylic textured finish
concrete block -rendered & painted
random groove strips
pa Ls al Re
L
rea) conc block - rendered
acrylic textured finish 8
|
U2L2 FFL 40,260 S Z
7)
U2-L1 FFL 37.260 5 l
Ee
wo)
5S
@)
7)
_UzloFFL93.985_\/,
columns - basement wall
reinforced concrete.off fo:
Site Control
Site control measures are to be followed to prevent erosion and sediment
export from leaving the site. A plan detailing the methods of control may be
fequired by council.
Noise emission from mechanical equipments shall comply with the local
council's Local Law No. 12.
In the instance of demolition, a waste management plan may be required by
council.
During the course of construction, property boundary fences are to be
maintained and replaced if necessary,
Energy Efficiency Requirements
§0mm Anticon insulation to be installed below roofing.
R2.5 Polywool ceiling insulation batts to be installed in roof space.
Vapour permeable RFL to all exterior framed walls.
R1.5 wall batts to all exterior framed walls.
All external Goors & windo' lo be fitted with a seal fo resrict air infilfration
and where glazed to be fitted with Pilkington ‘Evergreen’ glass.
All exhaust fans to conditioned spaces to be fitted with a self closing damper.
Hot water system shall be fitted with a heat trap within 1m of the outlet of the
heater and before the first branch.
Stormwater, Sewer and Water Supply
Roof & surface stormwater to be disposed of In accordance with council
requirements.
The site shall be connected to coucil's existing sewerage reticulating systems
and constructed in accordance with council standards & requirements.
The site shall be connected to council's existing town water supply and
constructed rainwater tanks are to be provided as per council requirements.
General Notes
¢ builder shall check and verify all dime
omissions fo the Architect.
Do not scale these drawings.
Drawings shall not be used for construction purposes until issued by the
Architect for construction.
RLis finished slab level
FLis finished floor level.
Refer to Engineering documentation for structural identification.
Refer to Hydraulic Engineer for plumbing design and layout.
Driveway cross-over and layback fo be constructed in accordance with local
Council regulations and design requirements.
Refer to Window and Door Schedule.
Smoke detectors to be installed in accordance with BCA regulations.
Waterproofing through-out to be applied as per manufacturers specification.
Trusses to be installed as per manufacturers specification.
Termite protection to be carried out in accordance with Australian Standards
and B.C.A. requirements.
All Windows & Doors to comply with relevant BCA regulations & Australian
Standards,
Balustrading installation and constructionto comply with BCA regulations and
relevant Australian Standards.
Pool fencing and gate construction and ressucitation signs to be installed to
comply with BCA regulations and relevant Australian Standards.
jons and verify all errors and
Termite Protection
The building shall be protected from subterranean termites by approved
physical and/or chemical barriers in accordance with AS3660.1. The precise
method of protection shall be determined by the owners and/or builder only
after consultation with a licensed pest control operator. This information then
shall be advised to the local government of licensed certifier prior to or at the
time of lodgement of the building permit approval.
Thereafter the owner/s shall ensure that any physical barriers are kept clear
of garden beds or soil build up, that any chemical barriers remain undisturb
and that annual inspections (plus eradication as necessary) are carried out
throughout the life of the building by a licenced pest control operator in
accordance with AS3660.1.
A 22-05-07 Details for Changes Application and
re-arrangement of poo! layout to unit 2
(refer to Decision Notice Condition 7)
CHANGE A
raising RL of basement level
CHANGE B
new front stair arrangement to unit 1
CHANGE C
additional visitor carpark
CHANGE D
new stair to side of buildings.
CHANGE E
replacement of balustrading with full
height screen
CHANGE F
new stair landing to stair from basement
CHANGE G
reduction in size of reflection ponds level 4
CHANGE H
unit 1, level 2, living room door to bifold.
; Project Designer
columns - basement walls ied iz
reinforced concrete.off form 1 ' je Y Will Franklin fs
, i [email protected]
' 1 7
[nnn nee n ten nnn dan en eee ene nnn en ene nn ne ee eee nee e nee - i Documentation
luminii to future detail os z - =
jumintui 1
Sandee ea 1 ‘ proposed new basement rele Watson
aoe aan ss floor level [email protected]
Lt. <4
Job No
JJ.61.04
Drawing No.
61.04.55 A
west elevation current level shown dotted
previously approved
Page 11
drawingregister
project Sunview Duplex
location 18 Dougias Stree. Sunshine Beach date of issue
client Dynamic Cates Pry Lid day 21 [23 ]25 f25.125 [25
job 416104 month {5 |5 |5 J5 |5 |5
page 3 of 3 year 7 7 |7 |? 7
distribution att: email address no. of copies
Private Certifiers take tones oneyenmos gid. gow. eh 4 t
Engineering Consultant Sean Sharp oar wreg&
Electrical Consultants Robert Graham
Landscaping Consultants Rob Burrell
Alan Sinclair & Associates Alan Roberson faze
Mechancial Consukants Rick Boyte A SOFIA LORIE CN AG
Hydraulics Consultant lan Dradtord [email protected] t qt
Noosa Council Op. Was 4
Noosa Councit changes App. | A+ ‘ 4
Noosa Council Demolition App. 4
doc (type) reason sent {by} comment (rcfer to codes on left)
o- orginal P= prekmunary h- hand document (type) d |d Ip Ip |p |p
Pp Pstper 2 - approval > COUNEL reason i i ja fa fa fa
r-reduced print {t- information mma sent (by) e le |h fh Th fh
C- compact disc ]t- tender @-emart from finivais) AW] WEI WE [WF IWF [WF
f- peif © = CONSLUCHON P- picked up
cd - hw t-revision f- fax
t pt ba - building app notes
drawing title doc.no. _size amendment no.
U Site / Roof Pian 1.04.01
U Plan 1.04.02
U Plan {2 1.04.03
FA 1.04.04
ICU Sections 1.04.05
CU Elevations / Sections 1.04.08
U Elevations 1.04.06
maneurering & 61.04.07
constructions area - Basement / Level 1 61.04.09
Constructions area - Level 2 / Level 3 61.04.10
Site / Roof Plan & Level 1 Plan (ut & U2) 61.04.11
Level 2 Plan (ut & U2} 61.04.12
Level 3 Plan (ut & U2) 61.04.13
Level 4 Plan (ui & U2 61.04.14
Sections 61.04.15
Sections / Elevations 61.04.16
Etevations 61.04.17
Changes Application - Plan A (ut & U2 61.04.52 At
Chai ication - Plan B (ul &u2) 61.04.53 At
Sections 61.04.54 Al
Elevations 61.04.55 Al
oO tional Works - Schematic Plan 61.04.30 Al A_A
Demolition Plan 61.04.31 A3 A
architecture * interiors * sustainahicbunidingdesign > planningdevclopmentstrategies
willfranklindesign * 51marystreetnoosavillegid4566 * p.0.box 1 354neosaheadsqid4ss7
telo754743237 *tax075474 1020 « [email protected]
Page 12
xm LAND USE SECTION FEES Sur MEMOLOSTA : RECEIPT TYPE SALE OF DOCUMENTS Superseded Planning Scheme Documentation §20 Copy of Permit/Approval Letter 110 The Noosa Plan Documentation 111 APPLICATION FEES Material Change of Use - Code/Impact Consistent 521 Inconsistent 521 Assessment under Superseded Planning Scheme 521 Modification to a Development Permit lS. oo 521 Extension of a Currency Period : 521 Operational Works - Landscaping 521 Bldg Work assessable against the Planning Scheme 521 PRE LODGEMENT REVIEW Half Hour 522 One Hour 522 ADVERTISING Purchase Advertised Applications 523 JETTIES Jetty Application Fee 524 Jetty Bond 51 (Category 4) BONDS Performance Bond : 51 (Category 9) SIGNS Registration Fee , . 222 SEARCH FEE . Search of Land Use Section file 112 Liquor Licensing Request 113 TOTAL $ S/F. 00 NAME: yurani Cafes ry LtA ADDRESS: 70 gx Zi7 Noosa Heats BLO 44567 FILE NO: _ (00F [2744 DATE: 30-S- 7007 RECEIPT NO: AGIA} Signature of TP Officer: V*.H AUTHORITY NO: 3 /2009/5794/ 2.
Page 13
CALCULATION OF FEES APPLICATION FEE TOTAL FEES MCU - CODE ASSESSMENT Details of Development Consistent 1.0 Inconsistent 3.0 FEE CALCULATION MCU - IMPACT ASSESSMENT Details of Development Consistent 1.0 Inconsistent 3.0 FEE CALCULATION OPERATIONAL WORKS Details of Development FEE CALCULATION TOTAL FEES
Used in these records
04/5743 - Change to development application [As Published]Related documentApplication case desk ↗
About this file
- File size
- 14.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file