Attachment 1 - Acoustic Report GSL Church Conditions

Attached to the e-mail Representation to Decision Notice - MCU17/0073.

of 12

Page text shows just the words. Original shows the document exactly as it was published.

                            Figure 2          Locality Plan and Noise Monitoring Location


   The results of the noise monitoring are summarised in Table 1, for a range of parameters.
   Background (BG or LA90) noise data was processed in accordance with the Department of Environment and
   Heritage Protection’s document Planning for Noise Control procedure to determine the Rating Background
   Levels1. Meteorological data from the Bureau of Meteorological Brisbane station was used in the validation
   of the background noise data.




   1 The rating background level is a single figure for each time period that represents the typical minimum LA90 levels

   for day, evening and night time periods. It is the median of the lowest 10th percentile of the LA90 levels.
Acoustics Noise Vibration                                      4                                0145 GSL Church Conditions Rpt 02