Skip to the record
Noosa's #1 Council Tracker.

Original source · versioned page text

Attachment 1 - Acoustic Report GSL Church Conditions

Attached to the e-mail Representation to Decision Notice - MCU17/0073.

of 12

Page text shows just the words. Original shows the document exactly as it was published.

   Worship Centre, Offices and Lower Level Meeting Room
   Noise modelling was undertaken using the measured levels for church services, children playing and office
   noise, to predict levels at the nearest residences. The assessment shows that the noise criteria based on the
   conditions (as shown in Table 2) can be met as follows:
   Worship Centre

          standard constructions for roof, ceiling and external walls;
          acoustic glazing to windows in the Sanctuary, and part of the Eastern wall (closest to the residences);
          air conditioning to enable doors and windows (closest to the residences) to be closed during services.
   Offices and Lower Level Meeting Room

          standard constructions for roof, ceiling and external walls;
          standard glazing;
          air conditioning to enable doors and windows (facing the residences) to be closed during louder
           activities (eg. children playing).
   One of the complaint items referred to noise from chairs being moved on the timber floor of the existing
   building. It is expected that this will relate in part to the setting out of chairs for worship services. The new
   worship centre will have concrete floors (ie. rather than timber) and the seats will be set out permanently
   for services. This will both reduce noise from seats being moved in the new worship centre, and also reduce
   the number of times seats have to be set out in the existing church building.
   The proposed alterations include allowance for the existing church building to be air conditioned. This will
   further reduce noise radiating to the nearest residences by enabling the doors and windows to be closed.
   Air Conditioning Plant
   Plant associated with air conditioning and ventilation for the alterations will be designed to meet the noise
   criteria based on the Draft Conditions (as shown in Table 2), at the nearest residences. The condenser plant
   is planned to be located away from the residential boundary.
   Friendship Terrace
   The friendship terrace will be used for informal gatherings after church services and for other gatherings. It
   is located outside the kitchen to enable people to have morning or afternoon tea. Noise levels from the
   covered friendship terrace have been predicted as shown in Table 4 based on noise levels measured in
   August 2018 for morning teas, and using the approaches as described in the Noise Criteria section of this
   report.




Acoustics Noise Vibration                                 9                             0145 GSL Church Conditions Rpt 02
Log in to download the original file

Attachment 1 - Acoustic Report GSL Church Conditions.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.