Original source · versioned page text
24.083_Seamount Quay_Issue A_05Nov24(2)(1)
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
5. Do not scale off drawings, use figured dimensions
Projected only. Any dimensions not nominated must be referred to
bou ndary the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
1500 wate
r allocation property details
boundary
1.825m
17°40'0"
No. 22 Seamount Quay
Noosaville QLD 4566
15000
Noosa Shire Council
(43.000m Locality - Noosaville
) Lot 91 on RP842151
13°35'40"
107°40'0"
Site Area - 866m²
Zone - Low Density Residential
water allocation area Overlays - Acid Sulphate Soils
- Flood Hazard
Existing revetment wall - Coastal Hazard
c an al
11.358m
q u ay
9678 from bdy
197°40'0"
Existing jetty to
be removed
11.358m
em t l
proposed
o unt
jetty
from screw in revetment wall - confirm
9797 from bdy
14.658m
10000 from revetment wall
se am
7100 from bdy
7105
5°27'10"
187°29'25"
2.000m
1500 water allocation boundary
Projected boundary (40.862m) 96°54'20"
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551 SDK SDK N3 BRETT & KIM GOSCHEN NEW JETTY SITE PLAN 01 A 24.083 A3
NORTH
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721 REV DATE DRAWN ISSUE
No. 22 SEAMOUNT QUAY, NOOSAVILLE Q 4566 SHEETS IN SET SCALE
A 05/11/24 SDK CONSTRUCTION ISSUE Lot 91 ON RP842151 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original