Original source · versioned page text
502746 Crawford - Amended Contract Plans 20220705
Attached to the e-mail Response to Information Request OPW22/0145 - 26 Dayspring St.
Original PDF page 2, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Last Published: Tuesday, 5 July 2022 2:05 PM
REFER TO SHEET 1 (COVER SHEET) FOR +/- 100mm TOLERANCE TO NOMINATED FINISHED FLOOR LEVELS. SETOUT EXTRA FEES ALERT (Designer/Builder Etc.)
ALL BUILDING INFORMATION REGARDING: SUBJECT TO MAXIMUM DRIVEWAY PROFILE AND/OR ANY FLOOD RELATED LEVELS LOT 57 on N21851
- SUSTAINABILITY REQUIREMENTS This Contour and Feature Survey as prepared by Axis Surveys does not
- SITE CLASSIFICATION CLIENT TO REMOVE TREES, STUMPS, ROOTS AND SLASH/SCRAPE LONG GRASS address the location of boundaries. Because of the age of the subject plan /
# 26 Dayspring St Cnr Wollomia Way
Line
- GENERAL BUILDING INFORMATION AND UNDERGROWTH FROM BUILDING AREA. WHERE STUMPS HAVE BEEN and / or missing boundary pegs, Axis Surveys will require additional fees for
REMOVED THE GROUND IS TO BE FILLED AND COMPACTED. extra control work to enable us to setout any proposed building work. Please
Suburb Sunrise Beach
Sewer
REFER TO WATER MANAGEMENT PLAN
)
contact this office for further advice.
e note
FOR ALL ROOF COLLECTION, SURFACE OWNER SHALL INSTALL AND MAINTAIN AN ALL-WEATHER ACCESS ROAD TO &
WITHIN THE PROPERTY BOUNDARIES AND UP TO THE BUILDING SITE, SUITABLE
DRAINAGE CONNECTIONS AND
Local Auth Noosa Shire Council
ximate
FOR ARTICULATED VEHICLES FOR CONSTRUCTION PURPOSES TO THE
on (Se
DISCHARGE SYSTEMS.
SATISFACTION OF THE BUILDER
GF TOTAL AREA = 205.11m² Lat:-26.4219 Area
WIND CLASSIFICATION N2 603m²
Appro
SITE CLASSIFICATION P SOIL SURFACE AS PER STA CONSULTING ENGINEERS ES
GF SITE COVERAGE = 34.01%
Locati
WITHIN 1 KM. OF 216018 DATED 4TH MARCH 2022.
BREAKING SALT WATER
YES
NO EVIDENCE OF FILL ON SITE. Long:153.1041
NO ROCK ENCOUNTERED AT TIME OF SITE INVESTIGATION.
WITHIN 100 M. OF SALT
WATER
NO WERE TREES IDENTIFIED WITHIN THE ZONE OF INFLUENCE OF THE PROPOSED FF TOTAL AREA = 158.58m² Tree Legend
BUILDING FOOTPRINT - NO
MINIMUM AHD FLOOR IS THE SITE SUBJECT TO MARINE/COASTAL FALLOUT - YES FF SITE COVERGAGE = 26.30%
NO
LEVEL APPLICABLE
SURVEY AREA NEW
RETAINING WALLS MUST BE PROVIDED IMMEDIATELY AFTER EARTHWORKS AND S
PRIOR TO ANY OTHER SITE WORKS COMMENCING. RESPONSIBILITY FOR
ASCONS
KDRB
EXISTING BLOCK RETAINING WALL
RETAINING WALLS INCLUDING REPAIRS OR MAINTENANCE, AS WELL AS REMOVAL SHOWN DASHED
LATITUDE 0° 00' 00" S Ø=Trunk Dia
H
SEWER OR REPLACEMENT OF EXISTING FENCING REMAINS WITH THE OWNER. EXISTING TREES TO BE REMOVED
TO BE REMOVED BY OWNER PRIOR
H=Tree Height
N
TO COMMENCEMENT OF WORKS
LONGITUDE 0° 00' 00" E BY OWNER PRIOR TO S=Tree
SL:31.9 EXISTING HOUSE SHOWN DASHED
Existing
COMMENCEMENT OF WORKS
Highset
Spread
House
TO BE REMOVED BY OWNER PRIOR
IL:31.2 TO COMMENCEMENT OF WORKS (Total Canopy)
DEPTH: 0.7 Ø
all
APPROX. LOCATION OF RETAINING WALL
WALL / OMP
3,450 WALL
3,000 EAVE
(APPROX.HEIGHT 800mm) BY OWNER AFTER
W
33.44
2
EARTHWORKS BUT PRIOR TO COMMENCEMENT
33.3
AIR CONDITIONING UNIT
°42'40 33 ting Brick
1,500
DRIVEWAY AND RETAINING WALLS BY OF SLAB WORKS. CLIENT TO LIAISE WITH SITE TREE SCHEDULE
.4
6
MANAGER PRIOR TO COMMENCEMENT.
OWNER UNLESS NOTED OTHERWISE IN 33
33.47
THE TENDER AND/OR COLOUR RL 32.200 RL 32.716 RL 33.067 No. Name T 'Ø' Spr 'Ø' 'H'
No Mk
Found
SELECTIONS DOCUMENTATION.
" .34
FILL 0.125 CUT 0.391
xis
157°30' CUT 0.742 1 TREE 0.60 m 7.0 m 10.0 m
Timber Fence 32.28 Timber Fence .2
33
2.61 E
33.11
PROPOSED TREES BY OWNER AFTER 32.14 32.80 32.695 32.91 33.13 33.29
2 TREE 0.50 m 5.0 m 5.0 m
11
32.97
32.58
ing Wall
32
13
10
8
12
7
9
14
No Mk
Garden 32.6432.34
32
Found
.2
32.49 32.54 32.72 32.97
HANDOVER UNLESS NOTED OTHERWISE
6
32.37
Existing Timber Sleeper Retain 33.18
32.46
3 TREE 0.40 m 6.0 m 5.0 m
.2
32.25 32.34 32.34
Existing Timber Sleeper Retaining Wall
IN THE TENDER DOCUMENTATION. 8,806
33.16258
32.24 HOT WATER SERVICE
4 TREE 0.30 m 2.0 m 4.0 m
32.31
GARAGE
Floor Level
15
32
32
THE OWNER(S) SHALL OBTAIN DEMOLITION APPROVAL PRIOR TO THE BUILDER
DAYSPRING STREET
RL 32.23
.3
.3
EXISTING SHED SHOWN DASHED .0
32.4
5 TREE 0.30 m 4.0 m 7.0 m
2
2
33
33
SUBMITTING FOR NEW HOME BUILDING APPROVAL. THE OWNER(S) ARE FULLY APPROX. DRIVEWAY
4,000
TO BE REMOVED BY OWNER EV CAR CHARGER
.2
9
RESPONSIBLE FOR ENSURING THEY HAVE REMOVED ALL EXISTING STRUCTURES AND AS PART OF DEMOLITION (G-FRAM-EV001) BY BUILDER 6 TREE 0.60 m 10.0 m 10.0 m
32.18
32.39
32.88
UTILITY SERVICES FROM THE PROPOSED CONSTRUCTION SITE I.E.
PAD RL CHANNEL GRATE 62m² TOTAL
32.88
32.03 32.12
- EXISTING HOUSE, CARPORT, SHED, PAVING, PATHS, GARDEN BEDS, DRIVEWAYS, BY BUILDER (47m² TO BDY) 7 TREE 0.60 m 10.0 m 10.0 m
Existing
Highset
32.325
House
SWIMMING POOL OR UNDERGROUND TANKS AND ALL BELOW GROUND FOOTING
Existing
8 TREE 0.30 m 4.0 m 7.0 m
CUT RL 32.706
Shed
247°30' 32.94
1
APPROX LOCATION OF SEWER CONNECTION
STRUCTURES.
- REMOVAL OF ANY TREES, STUMPS, BARK OR EXCESSIVE GROWTH WHICH MAY IMPACT
AS PER PRELODGEMENT TO BE CONFIRMED 4,982 32.40 32.29 CUT 0.381 9 TREE 0.30 m 4.0 m 5.0 m
ON SITE BY SITE SUPERVISOR PRIOR TO
WALL .8
Patio
6,686
10.439
32
32.66
ON CONSTRUCTION SITE ACCESS.
32.28
32.28
COMMENCEMENT OF WORKS.
10 TREE 0.40 m 4.0 m 5.0 m
32.07
- ALL BUILDING MATERIALS OR WASTE ON SITE IS TO BE FULLY REMOVED. .33
PORCH / FF
Approx. Invert Level 31.2m
32 70
5
Timber Fence
- ANY DEPRESSIONS TO NATURAL GROUND LEVEL WILL REQUIRE TO BE ADEQUATELY 32.27 . 11 TREE 0.50 m 4.0 m 5.0 m
4,532
32
LOCATION OF SOLAR PANELS .33 32
16
.6
Approximate House
32
.3
Approx. 0.7m deep
Connection Plotted
Supplied Records
From Statutory or
FILLED. .42
32
9
Patio
OMP PROPOSED 32
6,506 12 TREE 0.30 m 6.0 m 7.0 m
31.79
- ANY EXCESS FILL IS REMOVED WHICH MAY IMPACT ON CONSTRUCTION SITE ACCESS.
4 32.2432.11
FILL
32
17
UTILITIES / SERVICES: I.E. OMP 13 TREE 0.30 m 6.0 m 7.0 m
Timber Fence 67°30'
.2
32
RESIDENCE
4
32.24
32.24
.7
2.3532.41
19.0
- GAS METER AND ASSOCIATED PIPE WORK ARE REMOVED BACK TO SITE BOUNDARY.
32
RL 32.444
0
.1
32.2 14 TREE 0.30 m 6.0 m 7.0 m
3
- ELECTRICAL METER AND ASSOCIATED SERVICES ARE REMOVED TO AGREED SAFE
FFL 32.635
32.52
CUT 0.119
No Mk
Found
.4
32.14 Gate 32.07
32.13
DISTANCE See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.