AS 1428.1-2009 PWD Code
9 AS 1428.1—2009
Dimensions refer to finished surfaces (e.g., face of wall tiles and floor finishes).
Unless otherwise indicated, limiting dimensions for an inclined surface on a
continuous accessible path of travel shall be taken as horizontal and vertical only.
6 CONTINUOUS ACCESSIBLE PATHS OF TRAVEL
6.1 General
A continuous accessible path of travel shall not include a step, stairway, turnstile,
revolving door, escalator, moving walk or other impediment.
6.2 Heights of a continuous accessible path of travel
The minimum unobstructed height of a continuous accessible path of travel shall be
2000 mm or 1980 mm at doorways (see Figure 2).
6.3 Width of a continuous accessible path of travel
Unless otherwise specified (such as at doors, curved ramps and similar), the
minimum unobstructed width (see Figure 2) of a continuous accessible path of
travel shall be 1000 mm and the following shall not intrude into the minimum
unobstructed width of a continuous accessible path of travel:
(a) Fixtures and fittings such as lights, awnings, windows that, when open, intrude
into the circulation space, telephones, skirtings and similar objects.
(b) Essential fixtures and fittings such as fire hose reels, fire extinguishers and
switchboards.
(c) Door handles less than 900 mm above the finished floor level.