17 AS 1428.1—2009
7.4.2 Recessed matting
Matting recessed within a continuous accessible path of travel—
(a) where of metal and bristle type construction or similar, its surface shall be no
more 3 mm if vertical or 5 mm if rounded or bevelled, above or below the
surrounding surface; and
(b) where of a mat or carpet type material, shall have the fully compressed
surface level with or above the surrounding surface with a level difference no
greater than 3 mm if vertical or 5 mm if rounded or bevelled.
7.5 Grates
Grates shall comply with the following:
(a) Circular openings shall be not greater than 13 mm in diameter.
(b) Slotted openings shall be not greater than 13 mm wide and be oriented so that
the long dimension is transverse to the dominant direction of travel.
NOTE: Where slotted openings are less than 8 mm, the length of the slots may continue
across the width of paths of travel.
8 SIGNAGE
A1
8.1 Form of signs
The BCA contains requirements for Braille and tactile signage in Specification D3.6.
Where signs are required, the form of signs shall be as follows:
(a) Where required, raised tactile and/or Braille signage shall be provided as
follows:
(i) Sanitary facilities shall be identified with the following:
(A) Raised and visual versions of the international symbol of access.
(B) Raised and visual versions of the male and female symbols.
(C) Raised text that shall be in title case (e.g. Male Toilet).
NOTE: Title case has the first letter of each word capitalized and the rest
are lower case. Short articles, prepositions and conjunctions are not
capitalized.
(D) Braille that fully describes the visual information displayed by
symbols and raised text.
NOTES:
1 For example, a sign for a male accessible toilet will include the words
Male Toilet as visual, raised text and Braille as well as the raised
visual male symbol.
2 An example of a sign is given in Figure 9(a).
(ii) Signs for unisex accessible facilities shall be provided with the letters LH
or RH to indicate a left-hand or right-hand side transfer onto the WC pan.
The minimum font size shall be 20 mm san serif.
NOTES:
1 An example of right-hand side (RH) transfer is shown on Figure 9(a).
2 Helvetica and Arial are san serif fonts.
(iii) Entry doors to airlocks serving areas containing sanitary facilities shall
be identified by the use of raised text and Braille, together with raised
and visual symbols identifying each sanitary facility within.
www.standards.org.au © Standards Australia