AS 1428.1-2009 PWD Code
57 AS 1428.1—2009
13.2 Clear opening of doorways
The minimum clear opening of a doorway on a continuous accessible path of travel
shall be 850 mm when measured from the face of the opened door to the doorstop,
as shown in Figure 30. Where double doors are used, the 850 mm minimum clear
opening shall apply to the active leaf.
NOTE: For door controls, see Clause 13.5.
DIMENSIONS IN MILLIMETRES
FIGURE 30 CLEAR OPENING OF DOORWAYS
13.3 Circulation spaces at doorways on a continuous accessible path of
travel
13.3.1 General
Circulation spaces shall be provided at every doorway, gate, or similar entry way,
on a continuous accessible path of travel.
Circulation spaces at doorways shall have a gradient and crossfall not steeper than
1 in 40.
Doorway circulation spaces shall be used in combination to allow access through
doorways in both directions, as shown in Figures 31 and 32.
The dimensions shall also apply in mirror image configurations. Where clear
doorway openings are intermediate to those shown in Figures 31 and 32 then the
required circulation spaces shall be interpolated.
13.3.2 Swinging doors
The clear circulation space at doorways with swinging doors is based on the clear
opening width of the doorway (D). The clear circulation space shall be not less than
the dimensions specified in the tables of Figure 31 for the appropriate clear opening
width.