Original source · versioned page text
AS 1428.1-2009 PWD Code
5 AS 1428.1—2009
STANDARDS AUSTRALIA
Australian Standard
Design for access and mobility
Part 1: General requirements for access—New building work
1 SCOPE
This Standard specifies the design requirements for new building work, as required
by the Building Code of Australia (BCA) and the Disability (Access to Premises—
Buildings) Standards (Premises Standards), to provide access for people with
disabilities. Particular attention is given to—
(a) continuous accessible paths of travel and circulation spaces for people who
use wheelchairs;
(b) access and facilities for people with ambulatory disabilities; and
(c) access for people with sensory disabilities.
NOTE: The BCA and Premises Standards set out requirements for other features of the
accessible built environment not covered in this Standard, such as lifts, hearing
augmentation, tactile ground surface indicators, signage, glazing, lighting, car parking
and toilet numbers, and distribution.
This Standard does not include requirements for—
(i) wheelchairs that have dimensions exceeding those shown in Figure 1; or
(ii) motorized scooters.
2 APPLICATION
This Standard is referenced by the BCA and the Premises Standards for the
provision of access for people with disabilities. As a BCA and Premises Standards
referenced document, it is applicable to buildings as and when specified in the BCA
and Premises Standards.
NOTE: Compliance with this Standard may also be required by other regulatory
authorities.
This Standard provides the technical detail required to achieve the level of access
for a deemed-to-satisfy solution.
The requirements specified in this Standard are intended to permit general use of
buildings and facilities by people with disabilities acting independently, or where a
person’s usual method of operation is with an assistant, in the company of that
assistant.
NOTE: The Standard is based on data resulting from empirical testing of persons aged
between 18 and 60 years and may not be appropriate when applied to persons outside
this age range.
The dimensions stated in this Standard, relevant to the use of wheelchairs, relate to
the 80th percentile wheelchair size and user (see Figure 1), except at the following
locations where the 90th percentile dimensions are required:
(a) On an accessway, at the location of a turn greater than 60°.
(b) New accessible sanitary facilities.
www.standards.org.au © Standards Australia