AS 1428.1-2009 PWD Code.pdf
AS 1428.1—2009 74
A1 19 0 0 m i n. 4 3 0 m i n.
450 to 460 Distance
va r i e s
with basin
6 0 0 m a x.
used
400 max.
3 0 0 m i n.
50 to 6 0 50 to 6 0
Po r t a b l e s a ni t a r y 800 10
6 0 0 m i n.
di s p o s a l u n i t
4 50 m i n.
200 to 250
E xc l u s i o n zo n e E xc l u s i o n
23 0 0 m i n. line
14 0 0 m i n.
14 0 0 m i n.
E xc l u s i o n zo n e
E xc l u s i o n
zo n e
10 0 m a x.
3 3 0 m i n.
p e r m i t te d
e n c r oa c h m e nt
zo n e
L EG EN D
Ci r c u l ati o n s p a c e li n e
NOTE: This circulation space may overlap any other circulation spaces specified in this Standard.
DIMENSIONS IN MILLIMETRES
FIGURE 43 CIRCULATION SPACE FOR WC PAN—RIGHT-HAND TRANSFER
(LEFT-HAND TRANSFER IS MIRROR REVERSED)
15.2.9 WC doors
WC doors may be either hinged or sliding. WC doors shall comply with the
following:
(a) Outward-opening doors shall have a mechanism that holds the door in a
closed position without the use of a latch.
(b) Doors shall be provided with an in-use indicator and a bolt or catch. Where a
snib catch is used, the snib handle shall have a minimum length of 45 mm
from the centre of the spindle. In an emergency, the latch mechanism shall be
openable from the outside.
(c) The force required to operate the door shall be in accordance with
Clause 13.5.2(e).
(d) Door handles and hardware shall be in accordance with Clause 13.5.
© Standards Australia www.standards.org.au