Skip to the record
Noosa’s premier civic archive.

Original source · versioned page text

AS 1428.1-2009 PWD Code.pdf

of 116

Page text read automatically using OCR, there may be inaccuracies

 AS 1428.1—2009                                                              74



A1                                                                                19 0 0 m i n.                                   4 3 0 m i n.

                                                        450 to 460                                                                Distance
                                                                                                                                  va r i e s
                                                                                                                                  with basin
                                     6 0 0 m a x.
                                                                                                                                  used
                                     400 max.
                                                                                                    3 0 0 m i n.
                                       50 to 6 0                                                          50 to 6 0




           Po r t a b l e s a ni t a r y                                                                          800        10
                                                                                               6 0 0 m i n.
           di s p o s a l u n i t
                                                                               4 50 m i n.


                                           200 to 250
                                                                                                    E xc l u s i o n zo n e              E xc l u s i o n
                               23 0 0 m i n.                                                                                             line
                                                                                      14 0 0 m i n.


                                                        14 0 0 m i n.


                                                                 E xc l u s i o n zo n e

                                                                                                          E xc l u s i o n
                                                                                                          zo n e


                                                                                                   10 0 m a x.
                                3 3 0 m i n.
                                                                                                   p e r m i t te d
                                                                                                   e n c r oa c h m e nt
                                                                                                   zo n e

                                           L EG EN D
                                                             Ci r c u l ati o n s p a c e li n e

              NOTE: This circulation space may overlap any other circulation spaces specified in this Standard.


                                                          DIMENSIONS IN MILLIMETRES


               FIGURE 43 CIRCULATION SPACE FOR WC PAN—RIGHT-HAND TRANSFER
                         (LEFT-HAND TRANSFER IS MIRROR REVERSED)

        15.2.9 WC doors
        WC doors may be either hinged or sliding. WC doors shall comply with the
        following:
        (a)     Outward-opening doors shall have a mechanism that holds the door in a
                closed position without the use of a latch.
        (b)     Doors shall be provided with an in-use indicator and a bolt or catch. Where a
                snib catch is used, the snib handle shall have a minimum length of 45 mm
                from the centre of the spindle. In an emergency, the latch mechanism shall be
                openable from the outside.
        (c)     The force required to operate the door shall be in accordance with
                Clause 13.5.2(e).
        (d)     Door handles and hardware shall be in accordance with Clause 13.5.

 © Standards Australia                                                                                                                   www.standards.org.au

Log in to download the original (AS 1428.1-2009 PWD Code.pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.