89 AS 1428.1—2009
A1
DIMENSIONS IN MILLIMETRES
FIGURE 52 EXAMPLE OF OVERLAPPING CIRCULATION SPACES IN A SANITARY
COMPARTMENT
16 SANITARY COMPARTMENT FOR PEOPLE WITH AMBULANT DISABILITIES
16.1 General
Sanitary compartment for people with ambulant disabilities shall be in accordance
with Figures 53(A) and 53(B).
16.2 Grabrails
Grabrails shall be installed in accordance with Clause 17 and Figure 53(A).
16.3 Doors
Doors to sanitary compartments for people with ambulant disabilities shall have
openings with a minimum clear width of 700 mm, and shall comply with
Figure 53(B).
Doors shall be provided with an in-use indicator and a bolt or catch. Where a snib
catch is used, the snib handle shall have a minimum length of 45 mm from the
centre of the spindle. In an emergency, the latch mechanism shall be openable from
the outside.
16.4 Signage
Sanitary compartment for people with ambulant disabilities shall be identified by
symbol or words, as specified in Clause 8.