Appendix A - Response to Noosa Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn Specific Outcomes Probable Solutions Comments
pumping; or
S11.5 Basements for residential uses have flood immunity
above the 1% AEP defined flood event where alternative
means to mechanical pumping are used to achieve such
immunity; or
S11.6 Basements for non-residential uses have flood
immunity above the 1% AEP defined flood event that may
be achieved by means of mechanical pumping where the
mechanical feature is installed with adequate holding
tanks and an alternative back up power source.
Sloping sites S12.1 Buildings are of split level design that step down the O12 - Not Applicable. The site is not subject to steep land.
O12 On sloping sites, buildings and structures are designed slope or have suspended floor construction;
to maximise the use of natural slope and minimise the AND
need for cut and fill. S12.2 Cut or fill is less than 2m in depth relative to natural
ground surface;
AND
S12.3 The distance between the ground and the lowest
part of the floor of the building does not exceed 3m.
Roof form S13.1 Except for the Business Centre Zone, the main roof S13.1 & S13.2 - A dwelling house on each lot will need to
O13 Roof forms— of the building has a roof pitch no less than 5 degrees and comply with roof form design elements as part of
a) contribute positively to the local skyline; has minimum 600mm eaves to at least 75% of the subsequent building works application approval process.
b) complement the low density character of the locality; perimeter of the building;
c) do not present an appearance of excessive bulk to side AND
neighbours; S13.2 Buildings and structures do not include roof top
d) use simple traditional roof designs; and terrace areas.
e) do not create opportunities for residents to overlook
the private open space areas of neighbouring properties.
Landscaped setting No solution provided. O14 & O15 - Complies. The design layout ensures the
O14 Tall trees and native vegetation add to the character retention of significant vegetation on the site., comprising
of the locality and are retained; over 54% of the site as park.
AND
O15 Existing character trees such as eucalypts, poincianas, Please refer to Ecological Assessment prepared by Cardno
melaleucas and figs are retained. in Appendix C.
The development approval requires significant tree
JFP Ref: M1775 Page 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.