Appendix A - Response to Noosa Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnSpecific Outcome Probable Solution (if code assessment) Comment
b) reticulated sewerage; S16.1 For lots in urban settlements—power supply and has appropriately conditioned this aspect.
c) stormwater drainage; communications infrastructure are provided underground;
d) power supply; and OR It is noted that a subsequent operational works application
e) telecommunications; S16.2 For lots elsewhere—power supply and is required to be lodged.
communications infrastructure are provided underground
O16 The design and provision of public services and unless—
utilities, including sewerage, water, electricity, street a) located in the Rural Zone or Rural Settlement Zone and
lighting and telecommunication services— where not in a Bushfire Hazard Area as defined on Overlay
a) meets the needs of users; Maps OM1.4-OM9.4;
b) ensures health, safety and convenience of the b) new low voltage lines can be strung from poles carrying
community; existing high voltage lines; or
c) protects the natural environmental values of the site c) no extensions to the existing reticulation network is
and surrounds, including visual amenity and native necessary; or
vegetation; d) it is necessary to cross a body of water;
d) are cost effective over their life cycle;
e) minimises adverse impacts to the environment AND
(including the amenity of the local area) in the short and S16.3 Street lighting is provided in accordance with Section
long term; and 3.19 of PSP5 Engineering Design Standards – Roads,
f) ensures that the existing systems are upgraded or Drainage and Earthworks;
relocated to be capable of supporting the proposed AND
development; S16.4 For lots not within a sewerage service area—the lot
has sufficient area and other attributes to ensure
39
sustainable on-site sewerage disposal ;
Editor’s note:
PSP24 –Effluent Disposal details requirements for the
design and siting of effluent disposal systems where
located outside a sewerage service area. Compliance with
PSP24 will be considered as part of Council’s assessment of
the plumbing and drainage application.
39
PSP1 details information Council may request including an effluent
disposal report.
JFP Ref: M1775 Page 29