 NOOSA COUNCIL
APPROVED PLANS
   OPW14/0033
   1 APR 2014


[OCR of page images]
 

re

 

 

 

 

 

 

 

 

 

 

 

Aa

 

 

100 X 12 BAR BOLTED TO
rPONTOON FRAME WITH 2
M20 S.S BOLTS

\
- M20 SS BOLTS SECURED\
INTO PONTOON FRAME TRCK

SECTION A

JSP-208 PONTOON
FRAME

M20 S.S THREADED BAR
TAPPED & FULLY WELDED INTO
40 X 10 REINFORCING PLATE

 

 

750

JSP-208 PONTOON
FRAME

 

 

 

 

 

 

6mm PLATE GUSSET
TO BOTTOM CORNER4
BOTH SIDES

 

 
 
 

 

OVERLAPPED BOLTED
CONNECTION WITH

1 M20 S.S BOLT
THROUGH BOTH BARS

& INTO PONTOON FRAME

4 SINGLE ROLLER BRACKETS
[FIXED WITH 2 Mi2 ‘SS BOLTS

70

 

 

 

50 X 6 PLATE LUGS WELDED TO
TOP EDGE OF FRAME TO FIX

6mm AL. TREAD PLATE INFILL WITH
mMi2 SS BOLTS TO EACH LUG

[ —~~JSP-209 FLAT BAR
SURROUND FRAME

 

 

  

NAP IN FENDER

300 ROLLED FRAME CORNERS

PLAN VIEW -

 

SIDE VIEW

 

NOOSA COUNCIL
APPROVED PLANS

 

 

 

SECTION B

100 X 70% NYLON ROLLER
IN 128 X 63 X 8/6 CHANNEL
12¢ SS PI

 

 

 

 

 

ILE WALL

 

Tit

f
tnt
my
i
|

 

 

Ou

 

 

 

 

 

 

 

NOTES:
* ALL ALUMINIUM WORK TO COMPLY WITH AS1664.
* ALUMINIUM TO BE GRADE 6351-T5.
* ALL ALUMINIUM WELDING IN ACCORDANCE WITH AS. 1665
* ALL WELDS SHALL BE 8 C.F.W. U.N.O.
* ALL BUTT WELDS TO BE FULL PENETRATION.
* ALL BOLTS & FITTINGS TO BE 304 OR 316 STAINLESS STEEL.
* BOLT INSULATION SHALL BE ACHIEVED WITH A LIBERAL COATING OF DURALAC OR
LANOCOTE APPLIED TO ALL CONTACTING SURFACES.
* DIMENSION TOLERANCES U.N.O. SHALL BE:
FABRICATION — + 2.0 MACHINING - UP TO 10mm +0.1
> 10 TO 100mm +0.2
> 100mm + 0.5
ALL ANGLES +.05°
* REMOVE ALL SHARP CORNERS, BURRS & WELD SPATTER.
* ANY CHANGES TO BE NOTED AND RETURNED TO DRAWING OFFICE FOR REVISION

ULTIMATE LOAD CAPACITY = 8kN
ONLY SUITABLE FOR SMALL PONTOONS IN SHELTERED SITES
BERTHING SMALL, LIGHT WEIGHT VESSELS

A
THIS DRAWING IS SUBJECT TO COPYRIGHT AND CANNOT BE REPRODUCED IN PART OR FULL OR PASSED ON TO_A THIRD PARTY WITHOUT THE WRITTEN PERMISSION OF THE JETTY SPECIALIST

 

   

eleled

DATE

 

 

 

 

 

 

 

 

OPW14/0033
1 APR 2014
THE MARINA SPECIALIST c dn CHEN: AFM PVR CK ER JME: PILE BRACKET CONSTRUCTION
TONG AS ACN O108SS119 2 MMLETRAL AE ae (ST 28(S7) WYN dR TO SUIT 3158 - 3508 PILES
/ ED BY sp +r QLD. AUSTRALIA 4551 | JLevel 1, 5 Gordner Close; ion 4064 Fox (07 a8 9722 pe a5 pA; /9/05 Lise" 02
6/6/08 | BLOCKS REPLACED BY ROLLERS P.0. Box 388, Toowong 4066. Email: [email protected].ayy_ | PROJECT: : JSP-—SD-—
PHONE (07)5492 5925 > STANDAR AWING
a) Tee eTREICHED & PLE MOVED 75mm | JSP eRe FA) 482 600 | | CHECKED: rage DATE: om DRAWN | CHECKED |OMENSONS —__SSUE 3
AMENDMENT 1SSUI SPE CT AUIS T “| 4667 24~- §-of SYSTEM 2006 MA MILLIMETRES D A 3)

 

 

 

 

 

 

 

 

 

 

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

APPROVED PLANS - OPW14_0033.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.