-———_— 3000 ——__—____-+1

125 PFC
STEEL BEARERS |]

R.L 2.75m R.L_ 2.75m

 

RETAINING WALL TO BE

DESIGNED AND CERMFED
BY OTHERS TO SUPPORT LOAD:

PONTOON ACCESS STEPS FIXED
TO WALL WITH 2 M20 S.S BOLTS

 

 

 

3500

j
STANDARD PIANO HINGE CONNECTION
TO DOUBLE JOISTS AT OUTER EDGE

 

 

 

OF ACCESS STEPS

 

 

100 X 10 PLATE 600 LONG ~~ _|

 

WELDED TO PFC BEARERS

LET

 

 

 

 

CHEMSET TO WALL

 

100 X 100 X 3 .S.S SHS POSTS WITH
200 X 200 X 10 MOUNTING PLATE
TO FOOTING BOLTS

4 M12 S.S BOLTS CAST
500mm INTO FOOTING

4500 MASS CONCRETE FOOTING
REINFORCED WITH 4 / N12 BARS.
100 COG TO TOP

65 COVER 10 SURFACES

JOIST FIXED TO
100 X 50 X 6 PLATE CLEATS
WiTH 2 / M10 BOLTS

 

 

 

 

 

 

 

 

—|

 

 

2000

 

 

 

 

 

4
8
® ACCESS STEPS PLAN
T

2 STORAGE BOXES

 

 

 

 

 

 

 

    

SIDE ELEVATION

TIMBER NOTES:

All timber to be grade F17 hardwood
durability class 1 or 2

Decking to be 125 x 38 hardwood fixed
to joists with 2 / 12 gauge S.S screws
@ each joist.

Joists at 500 mox. crs to be 150 x 50
F17 fixed with 2 M10 S.S bolts to 100 x
50 x 6 cleats welded to bearers.

Fix bearers to block retaining wall with 2
M20 S.S bolts chemset 125mm into wall.
Fix bearer posts to concrete footings: with

4 / M12 SS bolts cast into footing. -

 

 

150 X SO HWD JOISTS
@ S500 MAX CRS

L

 

THE MARINA SPECIALIST

 

 

 

 

 

6500

  

 

 

TOP OF PILE R.L 3.0m

QUAY

 

 

 

ype PONTOON SHOWN ATLAT oi “UT RL -0.34m

 

 

LINE

LEVEL DATUM AHD R.L. 0.0
cot MLWS R.L. -0.17m

 

4m MIN EMBEDMENT
INTO STIFF CLAY
OR DENSE SAND

 

 

 

 

 

 

THIS DRAWING 1S SUBJECT TO COPYRIGHT AND CANNOT BE REPRODUCED IN PART OR FULL OR PASSED ON TO A THIRD PARTY WITHOUT THE WRITTEN PERMISSION OF THE JETTY SPECIALIST

 

 

 

 

 

 

 

 

 

 

CUENT: JILRIFT P/L TME:
TRADING 4S - ACN 010633119 2 INDUSTRIAL AVE Cardo cw: 051 om o02 LOT 257 (0) NOOSA PARADE ELEVATION
F fi/12 ES STEPS REPLACE WALKWAY CLE THE CALOUNDRA Carino (Gis) Pry Lad Ph (07) 3369 9822 i
E IW) HALKGORY de RETAINING WALL NOTE ADDED QLD. AUSTRALIA 4551 | ILevel 1, 5 Gerdner Close, istten 4064 Fox (07) 3369 9722 NOOSA HEADS SCALE: TE: DRAWING NO:
e / els pus eo i) 1 Fe prone (oni, s075 ra Box 388, Toowong 4066. a Emoi: sargetenrsno.com PROJECT: PROPOSED PONTOON & CATWALK 1:50 = 21/5/09 _| JSP-SJ-22121
(REY DATE AMENDMENT C ed aa 1 | 4467 JO. 27ND ) ; MA a MILLIMETRES F A3}

 

 

 

i

Used in these records

About this file

File size
1.5 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

10_0342 - Op Works, Prescribed Tidal Works - Jetty [As Published].pdf · 1.5 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.