fo100~{

 

bei zonk

 

 

 

 

 

T
80 X 100 X 10 washer!

SECTION A

100 X 12 BAR BOLTED TO
PONTOON FRAME WITH

M20 S.S BOLTS

100 X 12 CLEAT-

 

\ M20 SS BOLTS SECURING
ILE BRACKET TO

PONTOON FRAME TRACK

80 X 100 X 10 WASHER
pe CENTER NUT

 

900- |
t 350

 

 

Sood

 

M20 S.S THREADED BAR

TAPPED & FULLY WELDED INTO
40 X 10 REINFORCING PLATE

 

6mm PLATE GUSSET
TO BOTTOM CORNER
BOTH SIDES

COMMERCAIL 8 ROLLER BRACKET

 

 

 

 

 

 

 

 

 

FIXED WITH 10 Mi2 S.S BOLTS
SIZE TO SUIT PILE DIAMETER

          

50 X 6 FLAT BAR FULLY.
WELDED INSIDE FRAME

 

 

      

 

400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100-4

 

 

 

 

 

 

 

 

6mm TREAD PLATE
CLTED ONTO FRAME
WITH Ml2 S.S BOLTS

SP-209 FLAT BAR
SURROUND FRAME

NAP IN FENDER

77S

 

 

 

 

 

SIDE VIEW

H.DP.E. SLEEVE

6mm AL. TREAD PLATE

 

 

 

 

 

 

 

 

 

 

' Oo
\
c= .
f af i
bY SECTION B
7 SCALE 1:5
“PILE WALL

NOTES:
* ALL ALUMINIUM WORK TO COMPLY WITH AS1664.

* EXTRUDED ALUMINIUM TO BE GRADE 6351-15 OR 6063.

PLATE ALUMINIUM TO BE GRADE 5083.

*
* ALL ALUMINIUM WELDING IN ACCORDANCE WITH AS. 1665
* ALL WELDS SHALL BE 4 C.F.W. OR THE THICKNESS OF THE

THINNER MATERIAL. 1
* ALL BUTT WELDS TO BE FULL PENETRATION.

* ALL BOLTS & FITTINGS TO BE 304 OR 316 STAINLESS STEEL.
* ALL STAINLESS STEEL INCLUDING BOLTS, NUTS WASHERS SHALL

BE GRADE 316.

* ALL WELDING SHALL BE IN ACCORDANCE WITH 1554.
* BOLT INSULATION SHALL BE ACHIEVED WITH A LIBERAL COATING

OF DURALAC OR
SURFACES. {
* DIMENSION TOLERANCES U.N.O. SHALL BE:

LANOCOTE APPLIED TO ALL CONTACTING

FABRICATION — + 2.0 MACHINING — UP TO 10mm +0.1
> 10 TO 100mm +0.2

+> 100mm + 0.5

ALL ANGLES 21°

t J

PLAN VIEW
SCALE 1:10

300 RDLLED FRAME CORNERS

t

* REMOVE ALL SHARP CORNERS, BURRS & WELD SPATTER.

ULTIMATE LOAD CAPACITY = 40KkN

HIS DRAWING IS SUBJECT TO COPYRIGHT AND CANNOT BE REPRODUCED IN PART OR FULL OR PASSED ON 7O_A THIRD PARTY WITHOUT THE WRITTEN PERMISSION OF THE JETTY SPECIALIST

1

 

0 45/6/08 | WASHER TO CENTER BOLT ADDED JSP.
C 114/3/08 PLATE SIZES. ALTERED ENG
B 115/2/08) DECK PLATE DETAILS CHANGED JSP

 

 

 

 

DATE AMENDMENT

 

ISSUE/

THE MARINA SPECIALIST

TRADING AS ACN 010633119 2 INDUSTRIAL AVE
THE CALOUNDRA
OLD. AUSTRALIA 4551
Fale PHONE (07)5492 5925
Ls FAX. (07) 5492 6699
Ss P E—E CtlaAtvtss T

 

 

 

 

 

CUR: JiL Rit FIT vcTe TME: PILE BRACKET CONSTRUCTION TO SUIT )
Gerd FE ren: 051 074 982 tot 257 (52) NOOSA PDE 4009 — 4506 PILES & 8 ROLLER BRACKET
tee 1, § order Ce, ton 64 Fox (02) 3359 9722 Noosa thas. SCALE: pare: aoa
P.0, Box 388, Toowong 4066. Emoit:[email protected] | PROJECT: STANDARD DRAWING 4:40 __1:5 26/6/07_| JSP-SD—142
CRED, 7 IRP.E.Q. DRAWN J CHECKED [DIMENSIONS [ISSUE A3
(067 SYSTEM 2006 MA MILLIMETRES D v/)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Used in these records

About this file

File size
1.5 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

10_0342 - Op Works, Prescribed Tidal Works - Jetty [As Published].pdf · 1.5 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.