STEP SLOPE DOWN TO
ON SITE DAM
STEP SLOPE DOWN TO LINE
G FENCE
ON SITE DAM EXISTIN
EXISTING FENCE LINE General Notes
BULKHEADS TO UNDERSIDE OF RAKED CEILING ROOF CONSTRUCTION
BULKHEADS TO UNDERSIDE OF RAKED CEILING COLORBOND SHEET METAL OR ROOFING TILE TO BE
CONCRETE
FIXED IN
DRIVEWAY STAIR UNDER 3 X SKYLIGHTS TO BE CONFIRMED, AFTER INVESTIGATION BY
ACCORDANCE WITH MANUFACTURES SPECIFICATION.
ENERGY CONSULTANT FOR NATHERS COMPLIANCE IN NCC ALL RIDGE CAPPING, STEPS, HIPS VALLEYS AND VENT
CONCRETE FLASHINGS TO PROVIDE WATERPROOFING SYSTEM.
DRIVEWAY PROVIDE REFLECTIVE FOIL BACKED SARKING TO
PERGOLA UNDER UNDERSIDE
OF ROOF SHEETING. COLORBOND GUTTERING AND
PVC
DOWNPIPES TO BE CONNECTED TO STORMWATER
SYSTEMS
FALL 5° IN ACCORDANCE WITH THE LOCAL AUTHORITY.
ROOF WATER REQUIREMENTS AND CALCULATIONS
ARE
PROVIDED AS A GUIDE. ENSURE A QUALIFIED
PLUMBER/
BBQ EXHAUST PIZZA OVEN HYDRAULICS CONSULTANT REVIEWS THE DOWNPIPE
LAYOUTS
FIRE CHIMNEY EXHAUST
FALL 25°
PRIOR TO CONSTRUCTION.
DOWNPIPE LOCATIONS AS A GUIDE ONLY.
FALL 25°
ROOF SHEETING TYPICAL CORRUGATED LAYOUT TO BE CHECKED FOR COMPLIANCE BY
PROFILE. COLORBOND STEEL. QUALIFIED PERSONS PRIOR TO ORDERING AND
CONSTRUCTION.
COLOUR: SURFMIST
ALL SLOTTED GUTTERS AND DOWNPIPES TO BE
FALL 5° PERGOLA INSTALLED TO
NCC AND OR AS3500 (RELEVANT PARTS). MATERIALS
UNDER
USED ARE TO BE COMPATIBLE WITH ALL COMPONENTS
UPSTREAM AND DOWNSTREAM.
GABLE END
KITCHEN
FALL 25° FALL 25° ISLAND SURFACE WATER DRAINAGE MUST BE PREVENTED
COURTYARD
BENCH
BELOW FROM
FALL 5° GLAZING TO ABOVE WB2 BEAM UP ENTERING THE BUILDING WITH FGL SLOPING AWAY
TO UNDERSIDE OF RAFTERS. FROM THE
BUILDING & FINISHED SLAB LEVELS.
FALL 25°
BULKHEADS TO UNDERSIDE POSITION OF PROPOSED BUILDING TO BE VERIFIED BY
SUN HOOD OVER OF RAKED CEILING BUILDER ON SITE. LOCATION OF EXISTING SERVICES
GLAZING BELOW TO BE
VERIFIED BY BUILDER PRIOR TO CONSTRUCTION.
FALL 25° FALL 25°
FALL 25° FALL 25°
FALL 5° FALL 5° FALL 5°
PLANTER
PLANTER
PLANTER
SUN HOOD OVER SEATING
GLAZING BELOW AREA
FALL 25° STAIR UNDER
PITCH ANGLE TO BE CONFIRMED
ON SITE BY BUILDER TO MATCH
POOL DECK
SOLAR EXISTING TRUSSES TO REMAIN
WHIRLY BIRDS EXISTING
TUBE
move to western side so FALL 25° GABLE DORMA END
hidden from driveway ALL ROOF SHEETING
GABLE DORMA END CORRUGATED PROFILE
COLORBOND STEEL
FALL 25°
COLOUR SURFMIST
FALL 25° FIRE CHIMNEY POOL
PITCH ANGLE TO BE CONFIRMED EXISTING
ON SITE BY BUILDER TO MATCH
FALL 5° EXISTING TRUSSES TO REMAIN FALL 5°
FALL 5° FALL 25° FALL 25° FALL 5°
PITCH MAY REVERT BACK TO 6° PITCH MAY REVERT BACK TO 6°
TO MATCH EXISTING, SELECTED TO MATCH EXISTING, SELECTED
BUILDER TO CONFIRM COST BUILDER TO CONFIRM COST
BENEFIT TO MAINTAIN EXISTING BENEFIT TO MAINTAIN EXISTING
PITCH PRIOR TO DEMOLITION PITCH PRIOR TO DEMOLITION STAIR UNDER
STAIR UNDER
PROPOSED ROOF PLAN
1 1 : 100
RED LINE INDICATES EXISTING
DWELLING ROOF LINE EXTENT PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY
PROJECT REV DESCRIPTION DATE
7 HAPPY JACK CREEK ROAD, RIDGEWOOD QLD P1 EXISTING CONDITIONS 27/06/25 PROPOSED ROOF PLAN
22/05/2025 2:30:18 PM
P2 ISSUED FOR STRUCTURAL COORD 25/02/25
USE ONLY FIGURED DIMENSIONS P3 REVISED ISSUE FOR STRUCT. COORD 26/03/25
DO NOT SCALE OF DRAWINGS. P4 ISSUE FOR TENDER 22/05/25 Drawn: Checked: KW REV
N
COPYRIGHT ADRIAN RAMSAY CLIENT
QBCC 15256628 BISHOP, GEORGINA & JONATHAN SCALE
1 : 100 @ A2
DRAWING NUMBER
A112
P4
STUDIO 0403 235 604
CREATED WITH GENIUS AT RATWORKS STUDIOS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
BISHOP_250522_TENDER SET_compressed (1).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.