GENERAL NOTES COMPLIANCE NOTES COMPLIANCE NOTES CONTINUED COMPLIANCE NOTES CONTINUED COMPLIANCE NOTES CONTINUED
ALL WORKS TO COMPLY WITH THE BUILDING ACT 1975, ALL WORKS MUST EITHER COMPLY WITH THE CLADDING INSULATION LIVEABLE HOUSING (NEW HOMES ONLY)
THE NATIONAL CONSTRUCTION CODE (NCC)2022, THE PERFORMANCE SOLUTIONS SET OUT IN THE NCC 2022 METAL AND PLASTIC SHEET ROOF AND WALL CLADDING THERMAL INSULATION TO BE SELECTED AND INSTALLED DWELLING ACCESS TO COMPLY WITH PART 1 OF THE
QUEENSLAND DEVELOPMENT CODE, LOCAL AUTHORITY AND STATED BELOW, OR ACHEIVE THE SAME TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH IN ACCORDANCE WITH AS/NZS 4859, PART 13.2 OF THE LIVEABLE HOUSING DESIGN STANDARD.
REQUIREMENTS, AND ALL RELEVANT AUSTRALIAN PERFORMANCE REQUIREMENTS THROUGH COMPLYING AS/NZS 1562, PART 7.2 OF THE ABCB HOUSING ABCB HOUSING PROVISIONS AND MANUFACTURER'S DWELLING ENTRY TO COMPLY WITH PART 2 OF THE
STANDARDS. ANY OUTDATED STANDARDS LISTED IN WITH THE DEEMED-TO-SATISFY SOLUTIONS AS DETAILED PROVISIONS, AND MANUFACTURER'S DETAILS AND DETAILS AND SPECIFICATIONS. LIVEABLE HOUSING DESIGN STANDARD.
THESE NOTES ARE TO BE TAKEN TO REFER TO THE IN RELEVANT SECTIONS OF THE NCC 2022. SPECIFICATIONS. INTERNAL DOORS AND CORRIDORS TO COMPLY WITH
CURRENT EDIDITION. METAL DOWNPIPES AND RAINWATER FITTINGS TO BE HEALTH AND AMENITY PART 3 OF THE LIVEABLE HOUSING DESIGN STANDARD.
STRUCTURE MANUFACTURED, SELECTED AND INSTALLED IN INSTALL BUILDING MEMBRANES TO ALL NEW EXTERNAL THE GROUND OR ENTRY LEVEL OF A DWELLING MUST
CHECK ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO ALL NEW STRUCTURAL INSTALLATIONS SHOULD BE IN ACCORDANCE WITH AS/NZS 2179 AND PART 7.4 OF THE WALLS IN ACCORDANCE WITH AS/NZS 4200 AND PART HAVE AT LEAST ONE SANITARY COMPARTMENT, WHICH
COMMENCING WORKS. COMPLETE SET OUT OF THE ACCORDANCE WITH AS/NZS 1170 AND PART 2.2 OF THE ABCB HOUSING PROVISIONS. UPVC DOWNPIPES AND 10.8 OF THE ABCB HOUSING PROVISIONS. IS TO COMPLY WITH PART 4.2 OF THE LIVEABLE HOUSING
WORKS AND REPORT AND CLARIFY DISCREPANCIES TO ABCB HOUSING PROVISIONS. THE STRUCTURAL RAINWATER FITTINGS TO BE MANUFACTURED, ALL MECHANICAL INSTALLATIONS ARE TO BE IN DESIGN STANDARD, AND PART 6 WHERE RELEVANT.
THE DESIGNER PRIOR TO COMMENCING WORKS. INTEGRITY OF THE EXISTING BUILDING TO BE SELECTED AND INSTALLED IN ACCORDANCE WITH AS ACCORDANCE WITH AS 1668 AND PART 10.8 OF THE AT LEAST ONE SHOWER MUST COMPLY WITH PART 5.2
ADEQUATELY MAINTAINED DURING CONSTRUCTION. 1273 AND PART 7.4 OF THE ABCB HOUSING PROVISIONS. ABCB HOUSING PROVISIONS. OF THE LIVEABLE HOUSING DESIGN STANDARD, AND
FIGURED DIMENSIONS TAKE PRECEDENCE. DO NOT METAL ROOF AND WALL CLADDING TO HAVE SANITARY COMPARTMENTS TO BE CONSTRUCTED IN PART 6 WHERE RELEVANT.
SCALE OFF DRAWINGS. SITE WORKS PROTECTIVE COATING APPROPRIATE TO ENVIRONMENT ACCORDANCE WITH PART 10.4 OF THE ABCB HOUSING
REFER TO SITE SPECIFIC SOIL REPORTS OR CLASSIFY CONDITIONS IN ACCORDANCE WITH AS 1397 AND PART PROVISIONS. SUSTAINABLE HOUSING REQUIREMENTS
CHECK SERVICES DRAWINGS INCLUDING HYDRAULIC, THE SITE IN ACCORDANCE WITH PART 4.2 OF THE ABCB 7.2 OF THE ABCB HOUSING PROVISIONS. THERMAL PERFORMANCE OF THIS BUILDING CAN BE
MECHANICAL AND ELECTRICAL FOR SET OUT AND SIZING HOUSING PROVISIONS AND AS 2870. ENSURE MATERIAL COMPATIBILITY BETWEEN METALS FIRE SAFETY SATISFIED AS PER NCC VOL 2 SPECIFICATION 42, BY
OF SERVICES AND DUCTS WHERE APPLICABLE. NECESSARY EARTHWORKS TO BE UNDERTAKEN IN SUITABLE TO ENVIRONMENT CONDITIONS IN SMOKE ALARMS TO BE DESIGNED, INSTALLED AND ACHEIVING A MIN. ENERGY EFFICIENCY STAR RATING OF
ACCORDANCE WITH PART 3.2 OF THE ABCB HOUSING ACCORDANCE WITH PART 7.2 OF THE ABCB HOUSING CERTIFIED IN ACCORDANCE WITH AS 3786 AND PART 9.5 7 STARS, OR 6.5 IF IT HAS AN OUTDOOR LIVING AREA
COORDINATE ALL CONSULTANT DOCUMENTATION AND PROVISIONS. PROVISIONS. OF THE ABCB HOUSING PROVISIONS. SYSTEMS TO BE COMPLYING WITH SPECIFICATION 42 PART C2 , OR BY
IDENTIFY AND CLARIFY DISCREPANCIES WITH RELEVANT ALL NEW EXTERNAL WORKS TO DIVERT SURFACE WATER POWERED FROM CONSUMER MAINS POWER SOURCE COMPLYING WITH THE FOLLOWING PARTS OF THE ABCB
CONSULTANTS PRIOR TO COMMENCING RELATED FROM BUILDINGS AND STRUCTURES TO DISCHARGE TIMBER CLADDING TO BE SELECTED AND INSTALLED IN AND INTERCONNECTED WHERE THERE IS MORE THAN HOUSING PROVISIONS—
WORKS. POINTS COMPLIANT WITH PART 3.3 OF THE ABCB ACCORDANCE WITH PART 7.5 OF THE ABCB HOUSING ONE ALARM. PART 13.2, FOR THE BUILDING FABRIC; AND
HOUSING PROVISIONS. PROVISIONS AND MANUFACTURER'S SPECIFICATIONS. PORTABLE FIRE EXTINGUISHERS AND BLANKETS TO BE PART 13.3, FOR THE EXTERNAL GLAZING AND SHADING;
CHECK ONSITE DIMENSIONS PRIOR TO FABRICATION OF FIBRE CEMENT BOARD AND SHEET CLADDING AND PROVIDED DURING CONSTRUCTION IN ACCORDANCE AND
WINDOWS, DOORS AND JOINERY. SLABS AND FOOTINGS LINING TO BE SELECTED AND INSTALLED IN WITH AS 2444. PART 13.4, FOR BUILDING SEALING; AND
CONCRETE SLABS AND FOOTINGS, INCLUDING STEEL ACCORDANCE WITH PART 7.5 OF THE ABCB HOUSING ELECTRICAL INSTALLATIONS TO BE UNDERTAKEN IN PART 13.5, FOR CEILING FANS.
REFER TO BUILDING APPROVAL FOR SPECIFIC REINFORCEMENT, TO BE DESIGNED, INSTALLED AND PROVISIONS, AS/NZS 2908, AS/NZS 1859 AND ACCORDANCE WITH AS 3000. ENERGY EFFICIENT (E.E.) LIGHTING:
CONDITIONS AND ADDITIONAL REQUIREMENTS. CERTIFIED IN ACCORDANCE WITH AS 2870 AND SECTION MANUFACTURERS SPECIFICATIONS. A MINIMUM OF 80% OF TOTAL FIXED INTERIOR
4.2 OF THE ABCB HOUSING PROVISIONS. PARTICLEBOARD FLOORING TO BE INSTALLED IN PLUMBING AND DRAINAGE ARTIFICIAL LIGHTING TO THE DWELLING AND ATTACHED
ALL NEW SERVICES TO CONNECT TO EXISTING ON SITE ACCORDANCE WITH AS 1860 AND NCC 2022 H1. PLUMBING AND DRAINAGE INSTALLATIONS INCLUDING GARAGE SHALL BE ENERGY EFFICIENT LIGHTING TO
UTILITIES. CONFIRM SUITABILITY AND CAPACITY PRIOR REINFORCED CONCRETE WATER SERVICES, SANITARY DRAINAGE AND COMPLY WITH QDC MP4.1.
TO COMMENCING WORKS. CONCRETE AND CONCRETE STRUCTURES TO BE GLAZING STORMWATER DRAINAGE TO BE INSTALLED IN TAPWARE:
MANUFACTURED, DESIGNED AND INSTALLED IN GLASS AND GLAZING TO BE SELECTED AND INSTALLED ACCORDANCE WITH AS/NZS 3500 AND PARTS 3.3 AND 7.4 ALL SHOWER HEADS AND TAPWARE TO LAUNDRY TUBS,
ALL PROPIETARY MATERIALS SHALL BE USED AND FIXED ACCORDANCE WITH AS 3600. IN ACCORDANCE WITH AS 1288 AND PART 8.4 OF THE OF THE ABCB HOUSING PROVISIONS. INSTALLATIONS TO KITCHEN SINKS AND
STRICTLY IN ACOORDANCE WITH MANUFACTURER'S ABCB HOUSING PROVISIONS. ACCOMMODATE FOR POTENTIAL MOVEMENT OF SOIL. BASINS MUST HAVE A MINIMUM 3-STAR WATER
WRITTEN INSTRUCTIONS FOR USE UNDER THE MASONRY WINDOWS AND EXTERNAL GLAZED DOORS ARE TO BE REFER TO SOIL REPORTS FOR CLASSIFICATION. EFFICIENCY LABELLING AND STANDARDS RATING, TO
CONDITIONS APPLICABLE. PROVIDE DAMP PROOF COURSES AND FLASHINGS TO DESIGNED, MANUFACTURED AND INSTALLED IN HOT WATER RETICULATION SHALL BE TEMPERATURE COMPLY WITH QDC MP4.1.
NEW MASONRY WALL INSTALLATIONS IN ACCORDANCE ACCORDANCE WITH AS 2047 AND PART 8.2 OF THE ABCB CONTROLLED TO 50ºC OR BELOW TO BATHS SHOWERS TOILETS:
SURFACE WATER DRAINAGE MUST BE PREVENTED FROM WITH AS/NZS 2904, AND PARTS 5.7.4 AND 12.3 OF THE HOUSING PROVISIONS. AND BASINS IN ACCORDANCE WITH AS 3500. TOILET CISTERNS MUST HAVE DUAL FLUSH CAPABILITY
ENTERING THE BUILDING WITH FGL SLOPING AWAY FROM ABCB HOUSING PROVISIONS. GLAZED PANELS CAPABLE OF BEING MISTAKEN FOR AND HAVE A MINIMUM 4-STAR WATER EFFICIENCY
THE BUILDING AND FINISHED SLAB LEVELS MASONRY STRUCTURES TO BE DESIGNED AND INSTALLED UNOBSTRUCTED OPENINGS ARE TO BE MADE TERMITE RISK MANAGEMENT LABELLING AND STANDARDS RATING
IN ACCORDANCE WITH AS 3700 AND PART 5 OF THE ABCB APPARENT WITH PERMANENT DECALS OR VISION TERMITE MANAGEMENT BARRIERS AND INSTALLATIONS TO COMPLY WITH QDC MP4.1.
ABBREVIATION ON DRAWING SHEETS NOTED AS NCC. HOUSING PROVISIONS. MASONRY STRUCTURES IN SMALL STRIPS TO INDICATE ITS PRESENCE. TO BE DESIGNED AND INSTALLED TO AREAS WITHIN RAINWATER TANKS:
DENOTES NATIONAL CONSTRUCTION CODE FORMALLY BUILDINGS TO BE DESIGNED AND INSTALLED IN GARAGE AND LARGE PANEL DOORS TO BE DESIGNED PROPOSED WORKS IN ACCORDANCE WITH AS 3660, AS A RAINWATER TANK WITH A MINIMUM STORAGE
KNOWN AS BCA - BUILDING CODE 0F AUSTRALIA ACCORDANCE WITH AS 4773 AND PART 5 OF THE ABCB AND INSTALLED IN ACCORDANCE WITH AS/NZS 4505 AND 2870, AND PART 3.4 OF THE ABCB HOUSING CAPACITY OF 5000 LITRES MUST BE INSTALLED TO AS
HOUSING PROVISIONS. PART 2.2 OF THE ABCB HOUSING PROVISIONS. PROVISIONS. 3500 - PLUMBING AND DRAINAGE AND AS
PER QDC MP4.2 AND LOCAL AUTHORITY REQUIREMENTS.
FRAMING WATERPROOFING WORKPLACE HEALTH AND SAFETY
TIMBER FRAMED CONSTRUCTION SHOULD BE DESIGNED WET AREAS TO BE WATERPROOFED IN ACCORDANCE BUILDER SHALL COMPLY WITH ALL WORKPLACE HEALTH
AND INSTALLED IN ACCORDANCE WITH AS1684 AND NCC WITH AS 3740 AND PART 10.2 OF THE ABCB HOUSING AND SAFETY REQUIREMENTS REQUIRED BY
2022 PART H1D6. PROVISIONS. LEGISLATION FOR THE CONSTRUCTION OF THE
TIMBER STRUCTURES ARE TO BE DESIGNED IN EXTERNAL WATERPROOFING MEMBRANES TO BE DWELLING AND SHALL ASSESS ALL WORKPLACE HEALTH
ACCORDANCE WITH AS 1720.1 AND NCC 2022 PART H1D6. DESIGNED AND INSTALLED IN ACCORDANCE WITH AS AND SAFETY ISSUES BEFORE COMMENCEMENT OF
NAILPLATE TIMBER ROOF TRUSSES TO MANUFACTURERS 4654 AND NCC 2022 PART H2. CONSTRUCTION AND LIAISE WITH THE DESIGNER IF
DETAILS AND AS 1720.5. NECESSARY TO AVOID/MINIMISE RISKS DURING
STAIRWAY AND RAMP CONSTRUCTION CONSTRUCTION.
STEEL FRAMED CONSTRUCTION SHOULD BE DESIGNED SLIP RESISTANCE OF LANDINGS, STAIRS AND RAMPS TO
AND INSTALLED IN ACCORDANCE WITH AS/NZS 4600 AND BE IN ACCORDANCE WITH PART 11.2 OF THE ABCB
NCC 2022 PART H1D6. STEEL STRUCTURES TO BE HOUSING PROVISIONS AND AS 4586.
DESIGNED, INSTALLED AND CERTIFIED IN ACCORDANCE
WITH AS 4100 AND NCC 2022 PART H1D6.
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY
PROJECT REV DESCRIPTION DATE
7 HAPPY JACK CREEK ROAD, RIDGEWOOD QLD P1 EXISTING CONDITIONS 27/06/25 NOTES AND LEGENDS
22/05/2025 2:28:52 PM
P2 ISSUE FOR TENDER 22/05/25
USE ONLY FIGURED DIMENSIONS
DO NOT SCALE OF DRAWINGS. Drawn: Checked: KW REV
COPYRIGHT ADRIAN RAMSAY CLIENT
QBCC 15256628 BISHOP, GEORGINA & JONATHAN SCALE
1 : 100 @ A2
DRAWING NUMBER
A001
P2
STUDIO 0403 235 604
CREATED WITH GENIUS AT RATWORKS STUDIOS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
BISHOP_250522_TENDER SET_compressed (1).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.