        GENERAL NOTES                                       COMPLIANCE NOTES                                        COMPLIANCE NOTES CONTINUED                          COMPLIANCE NOTES CONTINUED                          COMPLIANCE NOTES CONTINUED

        ALL WORKS TO COMPLY WITH THE BUILDING ACT 1975,     ALL WORKS MUST EITHER COMPLY WITH THE                   CLADDING                                            INSULATION                                          LIVEABLE HOUSING (NEW HOMES ONLY)
        THE NATIONAL CONSTRUCTION CODE (NCC)2022, THE       PERFORMANCE SOLUTIONS SET OUT IN THE NCC 2022           METAL AND PLASTIC SHEET ROOF AND WALL CLADDING      THERMAL INSULATION TO BE SELECTED AND INSTALLED     DWELLING ACCESS TO COMPLY WITH PART 1 OF THE
        QUEENSLAND DEVELOPMENT CODE, LOCAL AUTHORITY        AND STATED BELOW, OR ACHEIVE THE SAME                   TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH     IN ACCORDANCE WITH AS/NZS 4859, PART 13.2 OF THE    LIVEABLE HOUSING DESIGN STANDARD.
        REQUIREMENTS, AND ALL RELEVANT AUSTRALIAN           PERFORMANCE REQUIREMENTS THROUGH COMPLYING              AS/NZS 1562, PART 7.2 OF THE ABCB HOUSING           ABCB HOUSING PROVISIONS AND MANUFACTURER'S          DWELLING ENTRY TO COMPLY WITH PART 2 OF THE
        STANDARDS. ANY OUTDATED STANDARDS LISTED IN         WITH THE DEEMED-TO-SATISFY SOLUTIONS AS DETAILED        PROVISIONS, AND MANUFACTURER'S DETAILS AND          DETAILS AND SPECIFICATIONS.                         LIVEABLE HOUSING DESIGN STANDARD.
        THESE NOTES ARE TO BE TAKEN TO REFER TO THE         IN RELEVANT SECTIONS OF THE NCC 2022.                   SPECIFICATIONS.                                                                                         INTERNAL DOORS AND CORRIDORS TO COMPLY WITH
        CURRENT EDIDITION.                                                                                          METAL DOWNPIPES AND RAINWATER FITTINGS TO BE        HEALTH AND AMENITY                                  PART 3 OF THE LIVEABLE HOUSING DESIGN STANDARD.
                                                            STRUCTURE                                               MANUFACTURED, SELECTED AND INSTALLED IN             INSTALL BUILDING MEMBRANES TO ALL NEW EXTERNAL      THE GROUND OR ENTRY LEVEL OF A DWELLING MUST
        CHECK ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO    ALL NEW STRUCTURAL INSTALLATIONS SHOULD BE IN           ACCORDANCE WITH AS/NZS 2179 AND PART 7.4 OF THE     WALLS IN ACCORDANCE WITH AS/NZS 4200 AND PART       HAVE AT LEAST ONE SANITARY COMPARTMENT, WHICH
        COMMENCING WORKS. COMPLETE SET OUT OF THE           ACCORDANCE WITH AS/NZS 1170 AND PART 2.2 OF THE         ABCB HOUSING PROVISIONS. UPVC DOWNPIPES AND         10.8 OF THE ABCB HOUSING PROVISIONS.                IS TO COMPLY WITH PART 4.2 OF THE LIVEABLE HOUSING
        WORKS AND REPORT AND CLARIFY DISCREPANCIES TO       ABCB HOUSING PROVISIONS. THE STRUCTURAL                 RAINWATER FITTINGS TO BE MANUFACTURED,              ALL MECHANICAL INSTALLATIONS ARE TO BE IN           DESIGN STANDARD, AND PART 6 WHERE RELEVANT.
        THE DESIGNER PRIOR TO COMMENCING WORKS.             INTEGRITY OF THE EXISTING BUILDING TO BE                SELECTED AND INSTALLED IN ACCORDANCE WITH AS        ACCORDANCE WITH AS 1668 AND PART 10.8 OF THE        AT LEAST ONE SHOWER MUST COMPLY WITH PART 5.2
                                                            ADEQUATELY MAINTAINED DURING CONSTRUCTION.              1273 AND PART 7.4 OF THE ABCB HOUSING PROVISIONS.   ABCB HOUSING PROVISIONS.                            OF THE LIVEABLE HOUSING DESIGN STANDARD, AND
        FIGURED DIMENSIONS TAKE PRECEDENCE. DO NOT                                                                  METAL ROOF AND WALL CLADDING TO HAVE                SANITARY COMPARTMENTS TO BE CONSTRUCTED IN          PART 6 WHERE RELEVANT.
        SCALE OFF DRAWINGS.                                 SITE WORKS                                              PROTECTIVE COATING APPROPRIATE TO ENVIRONMENT       ACCORDANCE WITH PART 10.4 OF THE ABCB HOUSING
                                                            REFER TO SITE SPECIFIC SOIL REPORTS OR CLASSIFY         CONDITIONS IN ACCORDANCE WITH AS 1397 AND PART      PROVISIONS.                                         SUSTAINABLE HOUSING REQUIREMENTS
        CHECK SERVICES DRAWINGS INCLUDING HYDRAULIC,        THE SITE IN ACCORDANCE WITH PART 4.2 OF THE ABCB        7.2 OF THE ABCB HOUSING PROVISIONS.                                                                     THERMAL PERFORMANCE OF THIS BUILDING CAN BE
        MECHANICAL AND ELECTRICAL FOR SET OUT AND SIZING    HOUSING PROVISIONS AND AS 2870.                         ENSURE MATERIAL COMPATIBILITY BETWEEN METALS        FIRE SAFETY                                         SATISFIED AS PER NCC VOL 2 SPECIFICATION 42, BY
        OF SERVICES AND DUCTS WHERE APPLICABLE.             NECESSARY EARTHWORKS TO BE UNDERTAKEN IN                SUITABLE TO ENVIRONMENT CONDITIONS IN               SMOKE ALARMS TO BE DESIGNED, INSTALLED AND          ACHEIVING A MIN. ENERGY EFFICIENCY STAR RATING OF
                                                            ACCORDANCE WITH PART 3.2 OF THE ABCB HOUSING            ACCORDANCE WITH PART 7.2 OF THE ABCB HOUSING        CERTIFIED IN ACCORDANCE WITH AS 3786 AND PART 9.5   7 STARS, OR 6.5 IF IT HAS AN OUTDOOR LIVING AREA
        COORDINATE ALL CONSULTANT DOCUMENTATION AND         PROVISIONS.                                             PROVISIONS.                                         OF THE ABCB HOUSING PROVISIONS. SYSTEMS TO BE       COMPLYING WITH SPECIFICATION 42 PART C2 , OR BY
        IDENTIFY AND CLARIFY DISCREPANCIES WITH RELEVANT    ALL NEW EXTERNAL WORKS TO DIVERT SURFACE WATER                                                              POWERED FROM CONSUMER MAINS POWER SOURCE            COMPLYING WITH THE FOLLOWING PARTS OF THE ABCB
        CONSULTANTS PRIOR TO COMMENCING RELATED             FROM BUILDINGS AND STRUCTURES TO DISCHARGE              TIMBER CLADDING TO BE SELECTED AND INSTALLED IN     AND INTERCONNECTED WHERE THERE IS MORE THAN         HOUSING PROVISIONS—
        WORKS.                                              POINTS COMPLIANT WITH PART 3.3 OF THE ABCB              ACCORDANCE WITH PART 7.5 OF THE ABCB HOUSING        ONE ALARM.                                          PART 13.2, FOR THE BUILDING FABRIC; AND
                                                            HOUSING PROVISIONS.                                     PROVISIONS AND MANUFACTURER'S SPECIFICATIONS.       PORTABLE FIRE EXTINGUISHERS AND BLANKETS TO BE      PART 13.3, FOR THE EXTERNAL GLAZING AND SHADING;
        CHECK ONSITE DIMENSIONS PRIOR TO FABRICATION OF                                                             FIBRE CEMENT BOARD AND SHEET CLADDING AND           PROVIDED DURING CONSTRUCTION IN ACCORDANCE          AND
        WINDOWS, DOORS AND JOINERY.                         SLABS AND FOOTINGS                                      LINING TO BE SELECTED AND INSTALLED IN              WITH AS 2444.                                       PART 13.4, FOR BUILDING SEALING; AND
                                                            CONCRETE SLABS AND FOOTINGS, INCLUDING STEEL            ACCORDANCE WITH PART 7.5 OF THE ABCB HOUSING        ELECTRICAL INSTALLATIONS TO BE UNDERTAKEN IN        PART 13.5, FOR CEILING FANS.
        REFER TO BUILDING APPROVAL FOR SPECIFIC             REINFORCEMENT, TO BE DESIGNED, INSTALLED AND            PROVISIONS, AS/NZS 2908, AS/NZS 1859 AND            ACCORDANCE WITH AS 3000.                            ENERGY EFFICIENT (E.E.) LIGHTING:
        CONDITIONS AND ADDITIONAL REQUIREMENTS.             CERTIFIED IN ACCORDANCE WITH AS 2870 AND SECTION        MANUFACTURERS SPECIFICATIONS.                                                                           A MINIMUM OF 80% OF TOTAL FIXED INTERIOR
                                                            4.2 OF THE ABCB HOUSING PROVISIONS.                     PARTICLEBOARD FLOORING TO BE INSTALLED IN           PLUMBING AND DRAINAGE                               ARTIFICIAL LIGHTING TO THE DWELLING AND ATTACHED
        ALL NEW SERVICES TO CONNECT TO EXISTING ON SITE                                                             ACCORDANCE WITH AS 1860 AND NCC 2022 H1.            PLUMBING AND DRAINAGE INSTALLATIONS INCLUDING       GARAGE SHALL BE ENERGY EFFICIENT LIGHTING TO
        UTILITIES. CONFIRM SUITABILITY AND CAPACITY PRIOR   REINFORCED CONCRETE                                                                                         WATER SERVICES, SANITARY DRAINAGE AND               COMPLY WITH QDC MP4.1.
        TO COMMENCING WORKS.                                CONCRETE AND CONCRETE STRUCTURES TO BE                  GLAZING                                             STORMWATER DRAINAGE TO BE INSTALLED IN              TAPWARE:
                                                            MANUFACTURED, DESIGNED AND INSTALLED IN                 GLASS AND GLAZING TO BE SELECTED AND INSTALLED      ACCORDANCE WITH AS/NZS 3500 AND PARTS 3.3 AND 7.4   ALL SHOWER HEADS AND TAPWARE TO LAUNDRY TUBS,
        ALL PROPIETARY MATERIALS SHALL BE USED AND FIXED    ACCORDANCE WITH AS 3600.                                IN ACCORDANCE WITH AS 1288 AND PART 8.4 OF THE      OF THE ABCB HOUSING PROVISIONS. INSTALLATIONS TO    KITCHEN SINKS AND
        STRICTLY IN ACOORDANCE WITH MANUFACTURER'S                                                                  ABCB HOUSING PROVISIONS.                            ACCOMMODATE FOR POTENTIAL MOVEMENT OF SOIL.         BASINS MUST HAVE A MINIMUM 3-STAR WATER
        WRITTEN INSTRUCTIONS FOR USE UNDER THE              MASONRY                                                 WINDOWS AND EXTERNAL GLAZED DOORS ARE TO BE         REFER TO SOIL REPORTS FOR CLASSIFICATION.           EFFICIENCY LABELLING AND STANDARDS RATING, TO
        CONDITIONS APPLICABLE.                              PROVIDE DAMP PROOF COURSES AND FLASHINGS TO             DESIGNED, MANUFACTURED AND INSTALLED IN             HOT WATER RETICULATION SHALL BE TEMPERATURE         COMPLY WITH QDC MP4.1.
                                                            NEW MASONRY WALL INSTALLATIONS IN ACCORDANCE            ACCORDANCE WITH AS 2047 AND PART 8.2 OF THE ABCB    CONTROLLED TO 50ºC OR BELOW TO BATHS SHOWERS        TOILETS:
        SURFACE WATER DRAINAGE MUST BE PREVENTED FROM       WITH AS/NZS 2904, AND PARTS 5.7.4 AND 12.3 OF THE       HOUSING PROVISIONS.                                 AND BASINS IN ACCORDANCE WITH AS 3500.              TOILET CISTERNS MUST HAVE DUAL FLUSH CAPABILITY
        ENTERING THE BUILDING WITH FGL SLOPING AWAY FROM    ABCB HOUSING PROVISIONS.                                GLAZED PANELS CAPABLE OF BEING MISTAKEN FOR                                                             AND HAVE A MINIMUM 4-STAR WATER EFFICIENCY
        THE BUILDING AND FINISHED SLAB LEVELS               MASONRY STRUCTURES TO BE DESIGNED AND INSTALLED         UNOBSTRUCTED OPENINGS ARE TO BE MADE                TERMITE RISK MANAGEMENT                             LABELLING AND STANDARDS RATING
                                                            IN ACCORDANCE WITH AS 3700 AND PART 5 OF THE ABCB       APPARENT WITH PERMANENT DECALS OR VISION            TERMITE MANAGEMENT BARRIERS AND INSTALLATIONS       TO COMPLY WITH QDC MP4.1.
        ABBREVIATION ON DRAWING SHEETS NOTED AS NCC.        HOUSING PROVISIONS. MASONRY STRUCTURES IN SMALL         STRIPS TO INDICATE ITS PRESENCE.                    TO BE DESIGNED AND INSTALLED TO AREAS WITHIN        RAINWATER TANKS:
        DENOTES NATIONAL CONSTRUCTION CODE FORMALLY         BUILDINGS TO BE DESIGNED AND INSTALLED IN               GARAGE AND LARGE PANEL DOORS TO BE DESIGNED         PROPOSED WORKS IN ACCORDANCE WITH AS 3660, AS       A RAINWATER TANK WITH A MINIMUM STORAGE
        KNOWN AS BCA - BUILDING CODE 0F AUSTRALIA           ACCORDANCE WITH AS 4773 AND PART 5 OF THE ABCB          AND INSTALLED IN ACCORDANCE WITH AS/NZS 4505 AND    2870, AND PART 3.4 OF THE ABCB HOUSING              CAPACITY OF 5000 LITRES MUST BE INSTALLED TO AS
                                                            HOUSING PROVISIONS.                                     PART 2.2 OF THE ABCB HOUSING PROVISIONS.            PROVISIONS.                                         3500 - PLUMBING AND DRAINAGE AND AS
                                                                                                                                                                                                                            PER QDC MP4.2 AND LOCAL AUTHORITY REQUIREMENTS.
                                                            FRAMING                                                 WATERPROOFING                                       WORKPLACE HEALTH AND SAFETY
                                                            TIMBER FRAMED CONSTRUCTION SHOULD BE DESIGNED           WET AREAS TO BE WATERPROOFED IN ACCORDANCE          BUILDER SHALL COMPLY WITH ALL WORKPLACE HEALTH
                                                            AND INSTALLED IN ACCORDANCE WITH AS1684 AND NCC         WITH AS 3740 AND PART 10.2 OF THE ABCB HOUSING      AND SAFETY REQUIREMENTS REQUIRED BY
                                                            2022 PART H1D6.                                         PROVISIONS.                                         LEGISLATION FOR THE CONSTRUCTION OF THE
                                                            TIMBER STRUCTURES ARE TO BE DESIGNED IN                 EXTERNAL WATERPROOFING MEMBRANES TO BE              DWELLING AND SHALL ASSESS ALL WORKPLACE HEALTH
                                                            ACCORDANCE WITH AS 1720.1 AND NCC 2022 PART H1D6.       DESIGNED AND INSTALLED IN ACCORDANCE WITH AS        AND SAFETY ISSUES BEFORE COMMENCEMENT OF
                                                            NAILPLATE TIMBER ROOF TRUSSES TO MANUFACTURERS          4654 AND NCC 2022 PART H2.                          CONSTRUCTION AND LIAISE WITH THE DESIGNER IF
                                                            DETAILS AND AS 1720.5.                                                                                      NECESSARY TO AVOID/MINIMISE RISKS DURING
                                                                                                                    STAIRWAY AND RAMP CONSTRUCTION                      CONSTRUCTION.
                                                            STEEL FRAMED CONSTRUCTION SHOULD BE DESIGNED            SLIP RESISTANCE OF LANDINGS, STAIRS AND RAMPS TO
                                                            AND INSTALLED IN ACCORDANCE WITH AS/NZS 4600 AND        BE IN ACCORDANCE WITH PART 11.2 OF THE ABCB
                                                            NCC 2022 PART H1D6. STEEL STRUCTURES TO BE              HOUSING PROVISIONS AND AS 4586.
                                                            DESIGNED, INSTALLED AND CERTIFIED IN ACCORDANCE
                                                            WITH AS 4100 AND NCC 2022 PART H1D6.




                                                                                                                PRELIMINARY NOT FOR CONSTRUCTION                                                                                                                                                                PRELIMINARY

                                                                                                                PROJECT                                                                                                       REV          DESCRIPTION                DATE
                                                                                                                7 HAPPY JACK CREEK ROAD, RIDGEWOOD QLD                                                                       P1     EXISTING CONDITIONS             27/06/25          NOTES AND LEGENDS




                                                                                                                                                                                                                                                                                                                                          22/05/2025 2:28:52 PM
                                                                                                                                                                                                                             P2     ISSUE FOR TENDER                22/05/25
                                                            USE ONLY FIGURED DIMENSIONS
                                                            DO NOT SCALE OF DRAWINGS.                                                                                                                                                                                            Drawn:           Checked: KW                  REV
                                                            COPYRIGHT ADRIAN RAMSAY                             CLIENT
                                                            QBCC 15256628                                       BISHOP, GEORGINA & JONATHAN                                                                                                                                      SCALE
                                                                                                                                                                                                                                                                                 1 : 100 @ A2
                                                                                                                                                                                                                                                                                                  DRAWING NUMBER
                                                                                                                                                                                                                                                                                                   A001
                                                                                                                                                                                                                                                                                                                                P2
STUDIO 0403 235 604
                                                                                                                                                                                                                                                                                                CREATED WITH GENIUS AT RATWORKS STUDIOS

Used in these records

About this file

File size
9.5 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

BISHOP_250522_TENDER SET_compressed (1).pdf · 9.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.