BATHROOM UNDER FLOOR HEATING ABOVE BENCH GPO HEIGHTS ( AB - CODE ) ELECTRICAL CONTRACTOR TO COORDINATE LOCATIONS WITH SELECTED FIXTURES BEING INSTALLED & JOINERY DRAWING DETAILS UNLESS NOTED ON PLANS AS PER BELOW TAG NUMBER
AS INDICTED BY : (NOTE 1 ) TAG IN ROOM 10 = 1000MM AFFL TO CENTRE OF GPO
11 = 1100MM AFFL TO CENTRE OF GPO
APPROXIMATE SQ M COVERAGE REQUIRED AS INDICATED BY [ GREY HATCH ], BUILDER AND FLOOR HEATING SPECIALIST TO CONFIRM COVERAGE REQUIRED IN EACH BATHROOM 12 = 1200MM AFFL TO CENTRE OF GPO
13 = 1300MM AFFL TO CENTRE OF GPO
TO BE PROVIDED AS AN IN SCREED SYSTEM OR LOW PROFILE UNDER TILE SYSTEM. 14 = 1400MM AFFL TO CENTRE OF GPO
BUILDING CONTRACTOR TO PROVIDE BEST FIT FOR PURPOSE SYSTEM AS RECOMMENDED BY THE UNDER FLOOR HEATING SUPPLIER / MANUFACTURER. 15 = 1500MM AFFL TO CENTRE OF GPO
16 = 1600MM AFFL TO CENTRE OF GPO
ELECTRICAL LEGEND
SINGLE GPO
POWER REQUIRED FOR LED STRIP LIGHTING IN JOINERY
DOUBLE GPO
CUPBOARDS, LIGHTS TO COME ON WHEN DOOR OPEN
WP
WEATHERPROOF DOUBLE GPO
ADDITIONAL DGPO UNDER SINK FOR ANY FUTURE
WATER FILTER OR ZIP UNIT INSTALLATIONS OV
GPO - OVEN HT TO SUIT LOCATION
SPOT
UNDER SINK PROVIDE GROMMET HOLE IN JOINERY DW
CARCUSS TO PASS DW CABLE THROUGH GPO - DISHWASHER 600H
SPOT
WM
GPO - WASHING MACHINE
USB
GPO WITH USB
D
UNDER BENCH PROVIDE GROMMET HOLE IN JOINERY DATA
CARCUSS TO PASS VACCUM CABLE THROUGH TO
W
W
W
W
W
W
DGPO LOCATION TWO-WAY SWITCH TO
LOWER GROUND FLOOR SINGLE SWITCH
WP
W 16 10 10 10 D LOCATION
UNDER SINK PROVIDE GROMMET HOLE IN JOINERY
CARCUSS TO PASS DW CABLE THROUGH VAC
OV BB DW
SINK DW
AB AB AB
TV
WP
S RANGE HOOD S
WP
S
WP
DOUBLE SWITCH
W
ADDITIONAL DGPO UNDER SINK FOR ANY FUTURE OV
WATER FILTER OR ZIP UNIT INSTALLATIONS 3 OFF ABOVE BENCH DGPO REFER JOINERY DRAWING J-2.0 TO J-2.1 THREE SWITCH
TO RIGHT SIDE OF WINDOW TV JOINERY & FIREPLACE
DW
UNDER BENCH TWO-WAY SWITCH
VAC IN DROP DOWN
S S
DW
BD
HATCH
SINK
USB USB USB USB
BIDET POWER POINT
AB
AB
11
11
600 H AFFL 600 H AFFL
BB
BB
W
MAIN SWITCHBOARD
16
MW
POWER REQUIRED FOR LED STRIP TASK LIGHTING W
UNDER OVER HEAD CUPBOARDS
DR
BB
11
10 AB
DB
DISTRIBUTION BOARD
AB
WM
BB
RANGE HOOD
GAS
RECESSED LED DOWNLIGHT
AB
10
FRZ
DR
BB
COOKER
S SURFACE MOUNTED LED DOWNLIGHT
11 AB
W
3 X DOMESTIC
AB
10
WM
BB
LARGE LPG TANKS
S S
FR
600 H WP
AT LOWER GROUND AFFL SD SINGLE SURFACE STRIP LIGHT
FLOOR LEVEL FOR LAUNDRY W
FR/FRZ
10 AB
W
REFER JOINERY
DOUBLE SURFACE STRIP LIGHT
FR
DRAWING J-6.0 TO
SINK
J-6.2
USB USB
CABINETRY STRIP LIGHT
SPOT
300 H
AB
10
AFFL UNDER BENCH CEILING MOUNTED
TWO-WAY SWITCH TO SD
IN DROP DOWN ELECTRIC HEATER ROUND PENDANT LIGHT
HATCH
AB
LOWER GROUND FLOOR
10
FOR KITCHEN &
GARAGE LOCATION ON
WALL AT BOTTOM OF PANTRY REFER STRIP PENDANT LIGHT
AB
STAIR WELL JOINERY DRAWING
11
J-1.0 TO J-1.9
S S
W
AB
UP W
CEILING FAN
11
HARDWIRED HEATED W
AB
TOWEL RAIL WALL LIGHT MOUNTED
SD SMOKE DETECTOR
11
TO COLUMNS
EXTERNAL SIDE
W
W
EXHAUST FAN
S
WP
USB USB
INSTANTANEOUS GAS HOT
WALL LIGHT
T
W
W
W
O
WATER SYSTEM WALL SPOT
SP
WP
MOUNTED, SUPPLY POWER
SPOT
SPOT LIGHT
300 H AFFL
W W
WP
ELECTRICAL NOTES
WALL LIGHTS
300 H AFFL MOUNTED TO
COLUMNS EXTERNAL
W
W
W
SIDE
W WP
MOUNTED IN 2600 H SD
CONFIRM SUPPLY CAPACITY PRIOR TO
COMMENCING CONSTRUCTION
300 H AFFL
LOWER CEILING OVER USB 300 H AFFL 300 H AFFL WP WALL LIGHT MOUNTED
DRAWER ( FURNITURE )
W 300 H AFFL TO COLUMNS
SM SM
LOCATION. SEPAERATE SM SM GPOS FOR SPECIFIC APPLIANCES AND
USB
SM SM
SWITCHED FROM HARDWIRED HEATED
EQUIPMENT TO BE SIZED TO SUIT
D
OTHER BEDROOM TOWEL RAIL
LIGHTS IN 3000 H RELEVANT POWER REQUIREMENTS. REFER
USB
TV
CEILING
TO MANUFACTURERS SPECIFICATIONS IN
W
300 H AFFL
300 H AFFL
ALL INSTANCES
SD SD
USB
W
300 H 3 X WALL MOUNTED PICTURE LIGHTS
300 H AFFL
AFFL
W MOUNTED TO JOINERY BULKHEAD
USB
DIRECTLY UNDER CORNICE
W
WP REFER JOINERY DRAWING J-3.0 TO J-3.1
TIMBER BOX FOR SEAT 300 H AFFL TV JOINERY
500MM HIGH LOCATED IN GENERAL NOTES:
THIS ZONE. HIGH OF GPO
TO SUIT NOT CLASHING
SD - SMOKE DETECTORS TO COMPLY WITH AS
3786 AND NCC VOL. 2 PART 3.7.5
W
WITH SEAT
HARDWIRED HEATED
TOWEL RAILS X 2 .
WALL MOUNTED PICTURE LIGHTS MOUNTED
TO WALL LINING DIRECTLY UNDER CORNICE.
W (d) SMOKE ALARMS MUST BE-
300 H AFFL MOTORISED UNDER DECK FLUSH MOUNTED
REFER JOINERY USB USB CENTERED ON WALL
DECK POOL COVER STORE AND ROLLER. INTERCONNECTED WHERE
DRAWING J-4.0 TO J-4.3 300 H AFFL
THERE IS MORE THAN ONE ALARM.
W
ELECTRICAL CONTRACTOR TO CONNECT
MASTER ENSUITE
ELECTRICAL CABLES TO MOTOR MECHANISM AS
WALL MOUNTED PICTURE LIGHTS MOUNTED CLOSER THAN 1.2M FROM POOL SPLASH ZONE - FIRST FLOOR WINDOWS TO COMPLY WITH
NOMINAL OPTION OF DISTRIBUTION TO WALL LINING DIRECTLY UNDER CORNICE.
BOARD FINAL LOCATION TO BE CENTERED ON WALL NCC 2019 VOL. 2 PART 3.9.2
DB
DESIGNED BY ELECTRICAL SD
300 H AFFL
W W
CONTRACTOR WITH LOCATION SIGNED
OF BY CLIENT. CEILING MOUNT TO
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
BISHOP_250522_TENDER SET_compressed (1).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.