Council archive · source document
BISHOP_250522_TENDER SET_compressed (1) · EXE25/0028
Original PDF page 16, section 1. The text section number identifies this passage in the reader.
ABOVE BENCH GPO HEIGHTS ( AB - CODE ) ELECTRICAL CONTRACTOR TO COORDINATE LOCATIONS WITH SELECTED FIXTURES BEING INSTALLED & JOINERY DRAWING DETAILS UNLESS NOTED ON PLANS AS PER BELOW TAG NUMBER
WATER FILTRATION NOTES:
10 = 1000MM AFFL TO CENTRE OF GPO
11 = 1100MM AFFL TO CENTRE OF GPO - BUILDER TO COORDINATE WITH PLUMBER
12 = 1200MM AFFL TO CENTRE OF GPO & ELECTRICAN TO ALLOCATE POWER
13 = 1300MM AFFL TO CENTRE OF GPO
14 = 1400MM AFFL TO CENTRE OF GPO SUPPLY AND BEST LOCATION FOR WATER
15 = 1500MM AFFL TO CENTRE OF GPO FILTRATION UNIT AT LOWER GROUND
16 = 1600MM AFFL TO CENTRE OF GPO FLOOR AREA. FOR CLEAN WATER SUPPLY
FROM WATER TANK SUPPLY
ELECTRICAL LEGEND
MOUNTED AT UNDERSIDE OF GROUND
FLOOR VERANDAH ROOF LINE, LOCATION
ABOVE SHOWN ON THIS LEVEL FOR SINGLE GPO
CONTEXT OF WHAT AREA SPOT LIGHT WILL
DIRECT LUMINANCE. DOUBLE GPO
WP
LED STRIP IN RAKED TWO WAY SWITCH FOR WEATHERPROOF DOUBLE GPO
WALL MOUNTED READING LAMPS CEILING UNDER STAIR STAIR LIGHTS OVER
FOR BUNK BED, FOR TOP AND OV
SPOT
BOTTOM BUNKS GPO - OVEN HT TO SUIT LOCATION
DW
SPOT
GPO - DISHWASHER 600H
W
WM
USB DGPO UNDER TOP GPO - WASHING MACHINE
BUNK FOR LOWER BEDS,
MOUNT ON SHELF UNIT USB
GPO WITH USB
D
DATA
W
W
600 H
300 H 300 H SINGLE SWITCH
W W
USB
DOUBLE SWITCH
USB
USB
USB
THREE SWITCH
D
W W 600 H
S S
SD TV
TWO-WAY SWITCH
BD
USB
SD BIDET POWER POINT
600 H 300 H
USB
MAIN SWITCHBOARD
USB
W
DB
DISTRIBUTION BOARD
W
3 X DOMESTIC 300 H RECESSED LED DOWNLIGHT
LARGE LPG TANKS
CEILING CEILING SD
S SURFACE MOUNTED LED DOWNLIGHT
W
SINGLE SURFACE STRIP LIGHT
AB DOUBLE SURFACE STRIP LIGHT
SPOT
11
600 H 600 H S CABINETRY STRIP LIGHT
TWO-WAY SWITCH TO AFFL AFFL S HARDWIRED HEATED LED STRIP UNDER OVERHEAD CUPBOARDS
LOWER GROUND FLOOR
GARAGE LOCATION ON
TOWEL RAIL FOR BAR BENCH TOP TASK LIGHTING ROUND PENDANT LIGHT
WALL AT BOTTOM OF FR
AB AB AB USB AB USB
STAIR WELL
STRIP PENDANT LIGHT
W
11 11 11 11
600 H
AFFL
DGPO UNDER STAIR LANDING FOR
600 H HARDWIRED HEATED
WINE FRIDGES
AFFL TOWEL RAIL CEILING FAN
S S S S W
W
WALL LIGHT TO UNDER STAIR SUPPLY POWER REQUIRED
STORAGE AREA MOUNT AS HIGH FOR A/C UNITS, QTY TO BE
AS POSSIBLE CONFIRMED BY BUILDER ON SD SMOKE DETECTOR
SITE WITH COORDINATION TO
NOMINAL OPTION OF MECHANICAL ENGINEER OR
EXHAUST FAN
WP
DISTRIBUTION BOARD FINAL
LOCATION TO BE DESIGNED BY LIFT A/C CONTRACTOR W PROPOSED HEAT PUMP
HOT WATER SYSTEM
ELECTRICAL CONTRACTOR WITH
LOCATION SIGNED OF BY CLIENT
DB
SPLIT SYSTEM W W WALL LIGHT
POOL PUMP POOL FILTER
SPOT
WP WP WP WP
SPOT LIGHT
ELECTRICAL NOTES
LIFT CONTROL BOX.
COORDINATE WITH LIFT SUPPLIER
ON CORRECT SIZE FUSE AND CONFIRM SUPPLY CAPACITY PRIOR TO
WIRE DIAMETER TO SUPPLY LIFT
POWER TO AVOID LIFT POWER
COMMENCING CONSTRUCTION
TRIPPING AFTER INSTALLATION GPOS FOR SPECIFIC APPLIANCES AND
EQUIPMENT TO BE SIZED TO SUIT
RELEVANT POWER REQUIREMENTS. REFER
TO MANUFACTURERS SPECIFICATIONS IN
ALL INSTANCES
GENERAL NOTES:
- SMOKE DETECTORS TO COMPLY WITH AS
3786 AND NCC VOL. 2 PART 3.7.5
(d) SMOKE ALARMS MUST BE-
INTERCONNECTED WHERE
THERE IS MORE THAN ONE ALARM.
- FIRST FLOOR WINDOWS TO COMPLY WITH
NCC 2019 VOL. 2 PART 3.9.2
ENERGY EFFICIENT LIGHTING
FLUORESCENT LIGHTS, COMPACT FLUORESCENT
LIGHTS (CFLS)
AND LEDS ARE TO BE USED IN A MINIMUM OF 80%
OF THE
TOTAL INTERNAL FLOOR AREA TO COMPLY WITH
THE QUEENSLAND
DEVELOPMENT CODE MP 4.1.
TOTAL AREA IS TO INCLUDE THE FLOOR AREA OF
THE GARAGE,
WHERE THE GARAGE IS ASSOCIATED WITH A
CLASS 1 BUILDING
OR SOLE OCCUPANCY UNIT.
PROPOSED LOWER GROUND ELECTRICAL PLAN
1 1 : 100
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY
PROJECT REV DESCRIPTION DATE
7 HAPPY JACK CREEK ROAD, RIDGEWOOD QLD P1 ISSUED FOR COORDINATION 14/05/25 ELECTRICAL PLAN LOWER GROUND
22/05/2025 2:30:26 PM
P2 ISSUE FOR TENDER 22/05/25
FLOOR
USE ONLY FIGURED DIMENSIONS
DO NOT SCALE OF DRAWINGS. Drawn: Author Checked: Checker REV
COPYRIGHT ADRIAN RAMSAY CLIENT
QBCC 15256628 BISHOP, GEORGINA & JONATHAN SCALE
1 : 100 @ A2
DRAWING NUMBER
A131
P2
STUDIO 0403 235 604
CREATED WITH GENIUS AT RATWORKS STUDIOS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
BISHOP_250522_TENDER SET_compressed (1).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.