NEW VERANDAH BEAM RB6 TO STRUCT. ENG'S
DESIGN, DETAILS AND SCHEDULE
ANTICON 60 BLANKET UNDER ROOF
NEW VERANDAH ROOF EXTENSION SHEETING, TO ENERGY REPORT
REQUIREMENTS EAVES GUTTER
NEW STRUCTURAL SUPPORT TO EXISTING TIMBER COLUMN -
CEILING CAVITY INSULATION AS ANTICON 60 BLANKET UNDER
3 1 2 --- REQUIRED TO COMPLY TO TOTAL R- ROOF SHEETING, TO ENERGY
EXISTING ROOF RAFTER VALUE OF ROOF TO ENERGY REPORT REQUIREMENTS
A221 A220 A220 REPORT REQUIREMENTS
CEILING CAVITY INSULATION AS
REQUIRED TO COMPLY TO
EXISTING ROOF FRAMING PROPOSED TIMBER NEW GLAZING & DOOR NEW GLAZING & DOOR NEW GLAZING & DOOR EXISTING GLAZING EXISTING GLAZING & DOOR TOTAL R-VALUE OF ROOF TO
VERANDAH BEAM TO STRUCT. ENERGY REPORT
ENG'S DESIGN DETAIL & EAVES GUTTER
NEW BEAM RB1 TO STRUCT. ENG'S DESIGN, DETAILS AND SCHEDULE REQUIREMENTS
EXISTING ROOF RAFTER EXPRESSED SPECIFCATION
ALONG DECK
PITCHING POINT PITCHING POINT
119400 119400 DINING ENTRY WIR BED 1 EAVES GUTTER
150
LIFT BEHIND
300
1100 300
EAVES GUTTER
EXTERNAL
ENS 1
U/S BEAM RB1
1200
NEW EXTERNAL DOOR WALL PROPOSED 90 X 90
U/S BEAM
CEILING HT
1700
3000
BAL 1 DOWNPIPES TIMBER COLUMNS
2600
2510
TYPICAL TO
2400
2100
VERANDAH BAL1
BALUSTRADE 2 ( BAL 2)
1200
1200H MIN TO POOL DECK EDGE
1000
PERGOLA
820
700
22
GROUND FLOOR FFL 116.36 GROUND FLOOR
116400 116400
145
185
SANDSTONE
RETAINING POOL DECK
WALL FFL 114.39 EXISTING
3400
EXISTING DWELLING EXISTING DECK
407
FFL 114.38 RL 114200 RETAINING WALL
FLOOR FRAMING SOLID HATCH IN BACKGROUND POOL
SOLID HATCH EXISTING
TIMBER SCREEN MOUNTED NGL
BETWEEN SHS COLUMNS
LOWER GROUND FFL 113.20 GARDEN SOIL / FILL LOWER GROUND
200
173
113000 113000
HEIGHT OF GARAGE SLAB
INTERNAL, SHOWN DASHED FOR OUTDOOR COURTYARD AREA
FOR CONTEXT COMPACTED ROAD BASE WITH FINE SANDSTONE RETAINING WALL
GRAVEL TOPPING
Section 6 Section 7
6 1 : 100 7 1 : 100
- ANTICON 60 BLANKET UNDER ROOF
REUSE WHIRLEY BIRDS SHEETING, TO ENERGY REPORT
--- REQUIREMENTS
FLASHING TO WHIRLEY BIRDS
CHIMNEY TO FIRE PLACE SOLAR TUBE
2
CEILING CAVITY INSULATION AS
A223 REQUIRED TO COMPLY TO TOTAL R-
VALUE OF ROOF TO ENERGY
REPORT REQUIREMENTS
FLASHING TO CHIMNEY STACK 90 840
EXISTING DECORATIVE TIMBER, EAVES GUTTER
OPENING OVER BEDROOM DOORS RAKING CEILING
EAVES GUTTER EXTENSION OF EXISTING DWELLING EAVES GUTTER
TO NORTH FACADE BULKHEAD
PITCHING POINT
119400 DINING ENTRY BED 3 BED 2 HALLWAY
DOWNPIPE
ROBE ROBE LINEN
BATH
EXISTING EXTERNAL WALL
PROPOSED OPTION FOR GLASS BALUSTRADE 2 ( BAL 2)
1200H MIN TO POOL DECK EDGE
JASMINE SCREENING
GROUND FLOOR
116400
POOL DECK
EXISTING
POOL
EXISTING
LOWER GROUND
113000
NEW CONCRETE PAD UNDER DECK FOR POOL OVERFLOW TANKS.
Section 8
8
CONFIRM ON SITE FOR LOCATION, EXTENT AND WATER TANK SIZING
1 : 100
PRELIMINARY NOT FOR CONSTRUCTION PRELIMINARY
PROJECT REV DESCRIPTION DATE
7 HAPPY JACK CREEK ROAD, RIDGEWOOD QLD P1 ISSUED FOR STRUCTURAL COORD 25/02/25 PROPOSED SECTIONS
22/05/2025 2:31:08 PM
P2
P3
REVISED ISSUE FOR STRUCT. COORD 26/03/25
ISSUE FOR TENDER 22/05/25
SHEET 3 OF 4
USE ONLY FIGURED DIMENSIONS
DO NOT SCALE OF DRAWINGS. Drawn: Author Checked: Checker REV
COPYRIGHT ADRIAN RAMSAY CLIENT
QBCC 15256628 BISHOP, GEORGINA & JONATHAN SCALE
1 : 100 @ A2
DRAWING NUMBER
A222
P3
STUDIO 0403 235 604
CREATED WITH GENIUS AT RATWORKS STUDIOS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
BISHOP_250522_TENDER SET_compressed (1).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.