SELECTED BI-FOLD TIMBER DOOR
SET DOWN SELECTED BI-FOLD
60MM MINIMUM WIDE GRATE TO SELECTED FRAMELESS GLASS BI-FOLD DOOR
TIMBER DOOR INTO A DRAINED SET DOWN SELECTED BI-FOLD TIMBER
TROUGH FOR EXTERNAL
TROUGH. DOOR INTO A DRAINED TROUGH. 60MM MINIMUM WIDE GRATE TO
DRAINAGE TO DOOR THRESHOLD
TROUGH FOR EXTERNAL
EXTERNAL FINISHED FLOOR LEVEL INTERNAL FINISHED FLOOR LEVEL. DRAINAGE TO DOOR THRESHOLD.
TIMBER DECK FLOORING 60 TIMBER TOUNGE & GROOVE FLOORING 20MM DEEP GRATE
INTERNAL FINISHED FLOOR LEVEL. EXTERNAL FINISHED FLOOR LEVEL
GROUND FLOOR TIMBER TOUNGE & GROOVE FLOORING TILE FINISH.
PROVIDE MAXIMUM 20MM SETDOWN FROM
20
116400
50
CUT OUT TO TOP OF GROUND FLOOR INTERNAL TIMBER FLOOR FINISH
(J1) JOIST
50 20
22
CUT OUT TO TOP OF AS REQUIRED 116400
140
TIMBER JOIST (J2)
10
CLOSE OF OPENING WITH BLOCKING
AS REQUIRED TIMBER JOIST (J1)
BETWEEN JOIST (J2)
AS REQUIRED BY STRUCTURAL SETDOWN IN SLAB EDGE TO ACCOMMODATE MINIMUM
ENGINEER @ 450 CENTRES TROUGH DEPTH OVERALL & WITH FALL IN TROUGH
235
TIMBER FLOOR JOIST (J2)
140 X 45 MGP12 H3 TREATED SUSPENDED CONCRETE SLAB TO
STRUCTURAL ENGINEERS DESIGN, DETAILS
STAINLESS STEEL OR INTERGARTED AND SPECIFICATIONS
ALUMINIUM SUBSILL TROUGH TO FULL TIMBER FLOOR JOIST (J1)
EXTENT OF DOOR OPENING. DRAIN 200 x 45 Hyspan @ 450 centres
VIA 50MM SPIGOT CONNECTED TO
FROG TRAP DRAIN
BLOCKWORK WALL UNDER STAINLESS STEEL OR INTERGARTED
CLOSE OF OPENING TO BLOCKWORK AND JOISTS ALUMINIUM SUBSILL TROUGH TO FULL
PAINTED FINISH EXTENT OF DOOR OPENING. DRAIN
COLOUR WHITE VIA 50MM SPIGOT CONNECTED TO
FROG TRAP DRAIN
FLOOR JOIST CONNECTION AS PER
STRUCTURAL ENGINEER'S DESIGN, SUPPORT AS REQUIRED / RECOMMENDED BY BI-FOLD DOOR
DETAILS AND SPECIFICATIONS MANUFACTURER, AND DOOR THRESHOLD DRAIN MANUFACTURER.
SHOWN IN STRUCT. ENGS DRAWING AS 200 PFC
Detail Door Threshold for Timber Bifold Door Detail Door Threshold Frameless Glass Bifold Door
1 1 : 10 2 1 : 10
PRELIMINARY NOT FOR CONSTRUCTION BUILDING
CONSTRUCTION
PRELIMINARY
APPROVAL
PROJECT REV DESCRIPTION DATE
7 HAPPY JACK CREEK ROAD, RIDGEWOOD QLD P1 REVISED ISSUE FOR STRUCT. COORD 26/03/25 DETAIL SECTIONS
22/05/2025 2:31:11 PM
P2 ISSUE FOR TENDER 22/05/25
USE ONLY FIGURED DIMENSIONS
DO NOT SCALE OF DRAWINGS. Drawn: Author Checked: Checker REV
COPYRIGHT ADRIAN RAMSAY CLIENT
QBCC 15256628 BISHOP, GEORGINA & JONATHAN SCALE
1 : 10 @ A2
DRAWING NUMBER
A240
P2
STUDIO 0403 235 604
CREATED WITH GENIUS AT RATWORKS STUDIOS
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
BISHOP_250522_TENDER SET_compressed (1).pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.