Minor Change Request (Planning Act 2016) 111 & 113 Gympie Terrace
Attached to the e-mail SUPESEDED - Change to DA - MCU16/0138.01.
Original PDF page 25, section 1. The text section number identifies this passage in the reader.
29560 4700
1245 3425 11150 2590 11150 2440 860 1400
7010 4140 1200 190 1200 4140 7010
1600 1500 5600 1500
100 thick nom. infill salb Opening
Opening Access Hatch Timber landing of stairs Edge of slab Access Hatch Access Hatch
Refer to engineering drawings for Edge of brickwork
slab & footing construction details. to engineers details. down the face of the and supporting
F.F.L.2.52m blockwork blockwork 840 300
Fixed base pad footing 450
Pad. 2.37m to engineers details. (50mm cavity)
Block retaning/Pool Edge
300
300
Block Fence 1m in from front boundary
2250
Pole Plate to formed pool
Pole Plate
2500
Pole Plate
2950
3950
3860
4460
4460
3860
Block Fence/block retaning
Subfloor ventilation
in accordance with NCC Part 3.4.1
Block work on top of slab - foorting to engineers detail.
Pole Plate Volume 2 . Mechanical vented Pool
7000
Intermediate block
piers to engineers detail. Subfloor ventilation
8515
300
300
in accordance with NCC Part 3.4.1
9085
Reinforced concrete footings Volume 2 . Mechanical vented
Pole Plate to formed pool
to engineers details. 600
Pole Plate
Intermediate block 3090
6835
F.F.L.2.82m piers to engineers detail.
Block work under slab
Pole Plate
Pole Plate
F.F.L.2.52m
12555
Edge of slab
4020
4160
Block up retaining to slab and supporting
100 thick nom. blockwork
Refer to engineering drawings for
5655
14720
F.F.L.2.52m 5610 F.F.L.2.82m
slab & footing construction details. 400
Pole Plate
F.F.L.2.82m 5610
2000
Pad. 2.59m
8095
Approx 1.4m fill to civil engineers details.
300
300
Pole Plate
1440 300
Edge of slab
3900
and supporting
Block Fence/block retaning
3100 blockwork
Pole Plate
Pole Plate
1620
2040
2040
2000
6205
5200
1630
Pool
Edge of footing/
1680
brick face.
Edge of brickwork Block Fence/block retaning
down the face of the
blockwork 50mm cavity, Block Fence
corefilled cavity between
block and brick
2460 2000 1200 300 5790 190 5790 500 3840 1620
5960 11770 - Slab 500 5460
450 3100 1120 600 2460 3200 12570 3840 1620 600 2440 860 1400 1690 1755
24890
37705
PROPOSED FOOTING/SLAB/FOUNDATION LAYOUT
C COPYRIGHT The Drawing and the design depicted on this sheet remains the property of Icon Building design. Reproduction in part or whole is prohibited unless written permission is obtained from Icon Building Design. Plans are design for use on the job address specified in the titleblock only.
Revision Schedule Client Name: J & S Payne
Revision Number Revision Description Revision Date Issued by Project Address: No. 111 Gympie Terrace, Noosaville Sheet Number:14 Project Number:16-024
A WD 1.0 Prelim 29/05/2017 B.Hunt
Climate Zone: 2
B WD 1.1 Prelim 10/08/2017 B.Hunt
Wind Category: To engineers spec.
Footing & Slab Plan
Phone: 0488209840
email: [email protected] Project Issue Date: 11/10/2017 Project Status: WD1.3 Scale: 1 : 100
website: www.iconbuildingdesign.com.au Checked/Signed By Director: Bradley Hunt Drawn By: BJH QBCC LIC# 126221
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.