engineer
exposed HWD roofing battens as per
—~ Remove existing tiled roof cladding
provide new custom orb corrugated colourbond
Sun ooaare ee
30 detail1 & 2
BAOO
| so nse gf
ea
[SW
to post support ————______
SCALE 1:100
to provide 600mm ohang
Fe
= aiamdive =alsned cone. base
north elevation
extend naw HWO roofing battens
JN
c.co
custom orb cormgated colourbond
roof cladding @ approx. 23° pitch to
match existing on roof battens
on timber truss to manuf. spec
custom orb corrugated colourbond
roof cladding @ 15° pitch on roof battens
on timber rafters to eng. spec 1
NOOSA SHIRE COUNCIL
PLANS APPROVED
SIGNATURE;
DATE:
iN
UU
het ye
refer floor plans for window & door sizes.
rendered block base to 500mm high
off f.f.1 supporting 200x200mm dressed
post to 2100mm H. fix directly/recessed
into post with 90 S.S column for timber
roof beam support
refer floor plans for extent of conc,
paving with square saw cut or tiled finish
fall from house.
all exist. brickwork make good for
new render paint finish
exposed HWD roofing battens as per
engineer
100mm box polystyrene awning
with render finish, fixing to manuf. spec.
ply famed tilt-up panel garago
door (ramote control) - paint finish
galv, steel frame
1540
OFFSET
_OP.
2400
existing
DP:
klip lock 700 roof sheeting @ min 18° pitch
over reftective backed 50mm R2.5 wool blanket
on 50x75 hwd roof battens on rafters
@ 900 ctrs to ang. spec.
2x min 5000 It water tanks
as per to M.S.C code requirements
on conc. base x contractor
allow 1x tank connection to W.C & W.M
with town water top up supply
Remove existing tiled roof cladding
provide new custom orb corrugated colourbond,
roof cladding @ approx. 23° pitch to
existing roof structure.-
iT
tl |
boundar
all exist. brickwork make good for
new render paint finish
east
y
boundar
EXIST.
Pitching_
2400.00
elevation
fail from house
SCALE 1:100
tefer floor plans for extent of conc.
paving with square saw cut or tiled finish
tefer floor plans for window & door sizes
and site conditions Inctuding location
contractor to confirm all dimensions, levels
specification and schedutes of finishes
-dimensions take precedent over scale
all footing, slab and all wall detalls, timber
and stee! framing, including bracing, tie-down
accordance with section 3.8 of the B.C_A
-stairs, handrails & balastrades to be in
timber frame salected paint finish
red Masonry
Battens 25mm spacings
T.C - 190mm wide profile CCA twd
G = Stratco hatf round zincalume gutter
RM = Rende: -painted .
of existing services on site prior to tha -do not scale from drawings and sizing of structural members accordance with section 3.9 of the B.C-A | AWN - F.C Awning 600mm fixed to Timber Cladding or similar approved SW Stidin
commencement of any works. -fefer specification for relevant -provide termite protection in accordance -conceal all vent pipes and waste pipes meta! support FCB - Fibro Cement Sheet SD Stiding Door
Australian Standards with AS 3680 within wall framing unless noted otherwise | R.S - Roof Sheeting (ref. elevations) —_Butt jointed - paint finish - LV
m design.
Michael Broeren
© TR IDEAS AND CONCEPTS CONTARED WITHIN THES
t 07 5 082 126] | Sense A anor en 148 P Alterations and Additions to: BU | LD | NG APPROVAL 071 6 B A-03
m@vg cm. SS el no Persimmon Dve 1700 OAS cy on A het
BSA No. 1050058 a AT Peragian Beach, For John & Liz Harrison |
GENERAL NOTES TO BUILDER ~drawings to be read in association with -fefer to structural engineers drawings for “waterproofing of wet areas to be in, LEGEND dered NRG board fed to Ee eae eee ee hwd Timber REV. oo 1007 peeiilial
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2184 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 558 KB (small file)
- File type
No other editions are linked here.