Skip to the record
The only place to find full transcripts.

Council archive · source document

10234lb08 - Bunnings Noosa Water Retic Amended Works · OPW14/0145.01

Attached to the e-mail OPW14/0145.01 - Request to Change to Existing Approval (Water Reticulation).

of 5

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

ENGINEERING

intelara

INTEGRATED SOLUTIONS
consultants. managers advisors.

Our Ref: 10234/Ib08/jn

25 October 2014

Noosa Council

Planning and Infrastructure
PO Box 141

TEWANTIN QLD 4565

Attention: Mark Lewis

Email: [email protected]

Dear Mark,

RE: 178 EUMUNDI NOOSA ROAD, NOOSAVILLE QLD 4566 (LOT 101 on SP.241371)
REQUEST FOR MINOR AMENDMENT TO DECESION NOTICE
COUNCIL APPLICATION No: OPW14/0145

We refer to our recent discussions in regards to the water services relocation connection works,
as part of water reticulation Operational Works for the above-mentioned development.

On behalf our client De Luca Corporation Pty Ltd, we hereby request Council’s acceptance to
the minor amendment to the recent Decision Notice of the Development Permit for Operational
Works (Sewerage and Water Main Reticulation) dated 29 May 2014.

In support of this application, please find attached the water reticulation design drawings
showing the revised works and relocation of the water service connection, dated 23 July 2014.

Furthermore, please note these drawings have been sent onto Unitywater to request for
Development Minor Works acceptance.

We trust this is satisfactory and look forward to receiving Council’s amended Decision Notice
shortly.

Should you require any further information, please do not hesitate to contact the undersigned at

this office or email [email protected] faithfully
INTELARA PTY LT!

  
 

James Nation
Associate

Enc.

Head Office Brisbane

Level 3, Northpoint

231 North Quay

Brisbane QLD 4000

p+61 73236 1100

www.intelara.com £ +61 73236 1155
Intelara PtyLtd ABN 70 093 117 232 e [email protected]
Full text of the other 4 pages

Page 2

(02-

e F9294 - Development Minor Works Variations Request Form

Unitywater

ABN: 89 791 717 472

Postal Address Unitywater Internet
PO Box 953 Ph: 1300 0 UNITY (1300 086 489) www.unitywater.com
Caboolture QLD 4510 Fax: 07 5431 8288 [email protected]

 

Consulting Engineer details:

Company:___ (WTR LEA ey Ub,

Name: VAMes Nation -

Daytime contact number:__O7 246 \\©o [oars SZBH S74.
Email: lamer. nnkon Cintelava. COW.

 

Contractor details:

Company:___ Devoe

Name: Mecttlley) WeLDeon -
Daytime contact number:__O7 2364 1600

 

 

 

 

 

 

 

 

Email: mrulaldven CASULA. com. ah

Development Works information:

Unitywater Connection Permit No: If /Ol45. Stage: Wa :

Street address: (7 DI Noosa. Conp Z

Real property description Lot: __ |O( Plan:__ 0. Z44 371.

Customer summary: F

Consulting Engineers Signature: te Date: 2s) ‘o] Zol#.
Contractor Signature: Date:

 

 

 

Variation Justification: (Ptéase specify the reasons for the variation and its impact on Unitywater network).

ZVAOUIN 6 WETER Seb)ice Codec).

 

 

 

 

 

 

 

Page 1 of 2
Document No: F9294 Revision No: 1 Effective date:1/07/2014 Next Review Date: 1/07/2016

 

Page 3

 

Variation Details: (The variation must either be sketched below or shown on a separate drawing and must be legible)

7 Feel To THe ATTACHED ayenper DRAWINGS TWerdeb BY
IHTELAPA PTY LTD, D¥AWING Hob 10264-ces revz 4
(0134-Co4 GAN Z, DATED 23/e7/2014,

 

 

Office use only
The proposed variation is APPROVED / NOT APPROVED.

Reason for Not Approved:

 

 

 

 

 

 

 

 

 

Officer's name: Position:
Signature: Date:
Daytime contact number: Email:

Privacy statement

Unitywater is collecting your personal information for the purpose of providing the requested service. The collection of this information is authorised
under the South East Queensland Water (Distribution and Retail Restructuring) Act 2009. Your information will not be given to any other person or
agency unless required by law or we have your permission in writing.

Page 2 of 2
Document No: F9294 Revision No: 1 Effective date:1/07/2014 Next Review Date: 1/07/2016

 

Page 4

 

 

 

ENVIRONMENTAL NOTES:

VEGETATION PROTECTION

A TREES LOCATED ALONG THE FOOTPATH SHALL BE, TRANSPLANTED
PRIOR TO CONSTRUCTION, OR REPLACED IF DESTROYED.

B. WHEN WORKING WITHIN 4m OF TREES, RUBBER OR HARDWOOD
GIROLES SHALL BE CONSTRUCTED WITH 1.8m BATTENS CLOSELY
‘SPACED AND ARRANGED VERTICALLY FROM GROUND LEVEL. GIRDLES
MUST BE STRAPPED TO TREES PRIOR TO CONSTRUCTION AND
REMAIN UNTIL COMPLETION.

C TREE ROOTS SHOULD BE TUNNELLED UNDER, RATHER THAN
‘SEVERED. IF ROOTS ARE SEVEREO THE DAMAGED AREA SHOULD BE
TREATED WITH A SUITABLE FUNGICIDE, CONTACT RELEVANT COUNCIL
ARBORIST FOR FURTHER ADVICE

 

 

 

 

 

 

 

 

 

 

 

NOTES

1, ALL WORK & MATERIALS SHALL BE IN ACCORDANCE
WITH CURRENT SOUTH EAST QUEENSLAND WATER
SUPPLY CODE SPECIFICATIONS AND STANDARDS.

2. UNLESS SPECIFIED OTHERWISE, ALL MATERIALS & WORK
SHALL COMPLY WITH THE RELEVANT AUSTRALIAN
STANDARDS.

. ADOPT TOP OF KERB AS PERMANENT LEVEL.

, COVER ON MAINS FROM PERMANENT LEVEL TO AS IN
SEQ-WAT-1200-2

, CONDUITS TO BE INSTALLED IN ACCORDANCE WITH
STANDARD DRAWINGS.

. A WATER METER SUPPLIED AT THE DEVELOPERS COST,

 

vorw

s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
    

 

 

 

 

 

 

 

D. _ ANY TREE LOPPING REQUIRED SHOULD BE UNDERTAKEN BY AN IS TO BE INSTALLED AT THE SERVICE POINT OF EACH
APPROVED ARBORIST. LOT IN ACCORDANCE WITH THE STANDAROS DRAWING
SOIL FOR THE SEQ SERVICE PROVIDER
A. TOPSOIL AND SUBSOIL SHALL BE STOCKPHLED SEPARATELY. 7. ALL MATERIALS USED IN THE WORKS SHALL COMPLY
B. CARE SHALL BE TAKEN TO PREVENT SEDIMENT FROM ENTERING THE WITH THE SEQ SERVICE PROVIDERS ACCEPTED PRODUCT
STORMWATER SYSTEM. THIS MAY INVOLVE PLACING APPROPRIATE AND) MA TERIALSILIS THOR/BE AEEROERIATELY, SHOWN
ee a ee (ee, LISTED AND DEFINED IN THE ENGINEERING SUBMISSION
SO THAT THE ALTERNATIVE PRODUCT OR MATERIAL
C. ACID SULPHATE SOILS EXIST IN THE WORKING AREA. THE OUTPUT [ANIGETASSES SEDIAND IAPPROPRIATENAPPRCVEDIBY
UBD MAP REF: SUN 18, £3 FROM THE RISK ASSESSMENT BASED ON THE QUEENSLAND ACID THE SEQ SERVICE PROVIDER "
LOCALITY PLAN SULPHATE SOIL TECHNICAL MANUAL REQUIRES THAT ACID & ALL CONCRETE FOOTPATHS TO BE CLEAR OF WATER
SCALE 14000 SULPHATE SOIL MANAGED AS FOLLOWS: (DELETE IF NO ACID MAINS.
SULPHATE SOILS} 9, TEST/CHLORINATION POINTS TO BE (NSTALLED IN
CREEK CROSSING ACCORDANCE WITH STANDARD DRAWING No.
A. SILTATION CONTROL MEASURES SHALL BE PLACED DOWNSTREAM OF SEW-WAT-1410-1
ANY EXCAVATION WORK. 10, THE CONSTRUCTION OF THE WATER RETICULATION
B. —_ APPROPRIATE SEDIMENT CONTROLS SHALL BE USED TO PREVENT WORK SHOWN ON THIS DRAWING MUST BE SUPERVISED
SEDIMENT FROM ENTERING THE CREEK. BY AN ENGINEER WHO HAS RPEQ REGISTRATION. WORKS
NOT COMPLYING WITH THIS REQUIREMENT WILL NOT BE
C. NO SOIL SHALL BE STOCKPILED WITHIN 5.0m OF THE CREEK
7 PERMITTED TO CONNECT TO THE RETICULATION SYSTEM
REHABILITATION
‘A PREDISTURBANCE SOIL PROFILES AND COMPACTION LEVELS SHALL
BE REINSTATED.
B —_ PREDISTURBANCE VEGETATION PATTERNS SHALL BE RESTORED.
ALL WATER AND SEWER CONSTRUCTION WORK
UNDERTAKEN BY THE CONTRACTOR SHALL
COMPLY WITH ALL APPLICABLE WORKPLACE
HEALTH AND SAFETY LEGISLATION.
AS CONSTRUCTED DETAILS
{CERTIFY THAT THE "AS CONSTRUCTED" DETAILS
SHOWN ON THIS PLAN ARE A TRUE AND ACCURATE
RECORD OF THE WORKS.
SIGNED. DATE,
NAME OF SIGNATORY (PRINT)
RPEQ No.
COMPANY NAME.
SERVICE DETAILS ASSET REGISTER WATER RETICULATION SERVICE DETAILS - ADDRESS
Wo. | SIZE LOT NUMBERS ESTATE/STAGE LOT 102 SERVICING TYPE/DIA. OF SERVICE. 150mm DIA
1_|150mm_|LoT 2 ON SP241371 179-184 EUMUNDI-NOOSA ROAD,
SITE ADDRESS NoosAvelle orntesse PIPE TYPE. PVC
1 fotimn {L072 ON SEZ 137) LENGTH OF SERVICE 16.140
METER TO LOT 2 ON SP241371 TO BE SUPPLIED ON APPLICATION LE ZAPPLICATION Misses Tal 2
(AT APPLICANTS EXPENSE} INS.C DELEGATES APP. DATE DATE COMMENCED, =
CLIENT DE LUCA CORPORATION PTY LTD DATE COMPLETED. a
DRAWING/PLAN No. SIGNATURE.
MAINS DIAMETER MATERIAL LENGTH SER. APPL. No,
DESIGN COST DESIGN COST
CHARGE:
150 pve | 46.140 |
DIAMETER MATERIAL LENGTH LEVELS - MIN COVER 600mm BELOW
DESIGN COST DESIGN COST
50 2430 | REMARKS FOR “WSI" RECORD
DIAMETER METER INSTALLATION BY CONTRACTOR
50 SUPPLY BY UNITY WATER.
FOR
CONSTR! 1
ee
Client Project DISCLAIMER & COPYRIGHT: i
SCALES BEFORE REDUCTION lien ra ject Drawing Title uy hark aod ¢ Miche Ls vgs andy nary id ENGINEERING Pe Ne BL)
ie raven transeittal ae an“) ravings
2_] WATER ALIGNMENT AMENDED [NSH] 274) 23.07.14 LOT 102 SERVICING WATER RETICULATION bea bniitnty ihc ee era ened intelara ik — a — x
40 0 40 80 120 160 =200m)/ 4 | FORCONSTRUCTIONISSUE [NSH] - = [30.05.14 179-184 EUMUNDI-NOOSA ROAD |] GENERAL NOTES AND DETAILS esas’ respuerubiity 18 check coapleteness of al internation en draviegs| INTEGRATED SOLUTIONS 44000 ' FEB. 2014
+4000 Oe B_| REVISED APPROVAL ISSUE | PC] AW | MRL | 19.02% Se Sa Lane Colca ee een LsL3 Northpoint, 231 North Quay ba) -
NOOSAVILLE QLD 4566 ‘Authecied Contralled fee” hard copies fermakly issued by lelara Py, Ltd ee oln tend Draving Non Taaanenr
A_| APPROVAL iSSUE PC - - 14.02.16 pote} ot eas, accordance with the Issue Status of the| ps 617.3236 1100 “7 3236 1155 arawing Number mendment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 5

 

 

LEGEND
SITE BOUNDARY
— — — _ ADJOINING BOUNDARY
— f—E— _ EXISTING ELECTRICAL DERIVED FROM DBYD
—— $—— S5—— _ EXISTING SEWER RETICULATION DERIVED FROM DBYD
— WwW —w — __ EXISTING WATER MAIN DERIVED FROM DBYD
—w ew —— _ EXISTING FIRE HYDRANT DERIVED FROM DBYD
—W >< W — ___ EXISTING VALVE DERIVED FROM DBYD
—— T——T—— ___ EXISTING TELECOMMUNICATION DERIVED FROM DBYD
-------- EXISTING KERB AND CHANNEL
(APPROXIMATE LOCATION)
WW >< )PROPOSED 150 DIA SERVICE

PROPOSED DOMESTIC
50mm METRE AND
WATER SUPPLY

PROPOSED 150mm FIRE
SERVICE CONNECTION

LOT 102
$P241371

SECTION OF EXISTING FOOTPATH TO BE
REMOVED & REINSTALLED ON THE COMPLETION
OF WORKS. REFER TO NOOSA COUNCIL
STANDARDS FOR CONSTRUCTION DETAILS.

CONNECTION TO EXISTING MAIN TO
BE CARRIED OUT BY UNITY WATER.
AT THE DEVELOPERS COST

DETAIL ¢ : 5
SCALE 1100

 

  
 

SP241371

LOT 102

   
 
 

 

HUET

 

 

 

 

(mo hT 4 s

LILLIE LY

 

Fea LULL
TTT TTT

TTTTITL
LULL

 

 

 

 

HET

 

 

 

CULL
. ELE
LI 1Lsle

 

 

 

 

lel |

 

 

TTT

LLL LLL
TTT ITTY

LLL LLL ELL
|

 

 

PULTE

 

 

 

 

 

 

 

SY

 

 

WAREHOUSE
LOT 101
$P241371

EXISTING BUNNINGS

 

 

 

 

WATER RETICULATION LAYOUT PLAN

SCALE 1:500

 

 

 

 

 

   

 

WARNING

BEWARE OF UNDERGROUND SERVICES
THE LOCATION OF EXISTING UNDERGROUND
SERVICES ARE APPROXIMATE ONLY AND THEIR
EXACT POSITION SHOULD BE PROVEN ON SITE. NO
GUARANTEE IS GIVEN THAT ALL EX!STING
SERVICES ARE SHOWN.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCALES BEFORE REDUCTION ZA
1 oo 4 2 3 ks mf 2 | WATER AuicNMENT AMENDED [nsH] 247) 23.07.1%
1:100 1 | FOR CONSTRUCTION ISSUE [NSH] - AS} 300516
. C | RESPONSE TOCOUNCL AFL | PC] AW | MAL | 22.00.16)
S$ 0 §$ 1 15 20 2 m|| B | REVISED APPROVAL ISSUE | PC =| 1902.
1500 ‘A_| APPROVAL ISSUE PC 16.02.%

 

 

 

 

 

 

 

 

Issue Description By | Verif'd | Aprov't| Date

 

 

Client

deluca

Project

LOT 102 SERVICING
NOOSAVILLE QLD 4566

 

 

179-184 EUMUNDI-NOOSA ROAD

Drawing Title

WATER RETICULATION
LAYOUT PLAN AND DETAILS

 

 

   
  

 

 

 

 

 

 

 

 

 

 

4. A LZ
CONSULTANT: INTELARA Pty Ltd
CONTACT: JAMES NATION FOR siete aaa te
TELEPHONE: (07) 3236 1100 CONSTRUCTION
DISCLAIMER & F - .
yrs ad econ he ravings end bynes Phy ENOINEERING — Designed venay
cempiete with deaeing tania ace an “Autborned Cenreled tue" Oravnga| inte ofa PC No
istued electronically in AutoCAD dug tite format are “Uncontrolled Copies”
ed tetare Ply Ue. accepts oo responsibaity for thelr use or distribution, Scale Apprgfes Date
it is Ibe user's Te hack completeness of al information on drawings INTEGRATED SOLUTIONS AS SHOWN FEB, 2014
con eectrericshy| Tranuritted AutoCAD vg ¢raving fies against meee {at .
"wutherined Contrelled Issue” hard copies (ereally issued by Intelara Ply. Lid Daa ec niaah Drawing Nont
and use that information only in accordance with the Issue Status of the] ase ae ey Irawing Number Amendment,
pe whe -
bee vased wiles ‘ihe wri heyhey at iarelars Ply tte w: wwwintelara cam - ABN 07 093 117 232 10234 Co4 2

 

 

 

 

 

Used in these records

About this file

File size
521 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

10234lb08 - Bunnings Noosa Water Retic Amended Works.pdf · 521 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.