Original source · versioned page text
QB1910553 - STG 1 19 Ind Units - Lot 13 (#64) - QB1910553 - MISC - Form 11 Final & Supporting Certificates - 26.11.2021 KW
Very large file: it may take a few minutes
The original of this document is very large (10.4 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.
18556-F16-1A 4. Description of component/s certified Clearly describe the extent of work covered by this certificate, e.g. all structural aspects of the steel roof beams. 5. Basis of certification Detail the basis for giving the certificate and the extent to which tests, specifications, rules, standards, codes of practice and other publications, were relied upon. 6. Reference documentation Clearly identify any relevant documentation, e.g. numbered structural engineering plans. All Structural aspects for Stage 1 buildings, 64 Gateway Drive: - _ Reinforced concrete footings, piers, beams and slabs on grade, - _ Reinforced concrete blockwork walls, - _ Precast concrete wall panels, - Structural steel columns and beams, - Structural steel purlins and rafters, - Structural steel floor joists. Certification of Screwpiles by piling contractor. Inspections of works in progress as per attached site notes. Tod Consulting Project 18556 drawings numbered: 18556-S01 to $17. Tectonic Geotechnical Reports 19201-001 and 002 Revd, 7. Building certifier reference Building certifier reference number Development approval number number and development approval number | QB1910553 | | QB1910553 8. Building certifier, competent Name (in full) Person or QBCC licensee details A competent person must be assessed as competent before carrying out the inspection. The builder for the work cannot give a Stage certificate of inspection. A competent person is assessed by the building certifier for the work as competent to practice in an aspect of the building and specification design, because of the individual's skill, experience and qualifications. The competent person must be registered or licensed under a law applying in the State to practice the aspect. If no relevant law requires the individual to be licensed or registered, the certifier must assess the individual as having appropriate experience, qualifications or skills to be able to give the help. If the chief executive issues any guidelines for assessing a competent person, the building certifier must use the guidelines when assessing the person. [ Hamish Gray — B.Eng, R.P.E.Q, M.LE. Aust | Company name if applicable Contact person | Tod Consulting Pty Ltd ‘| [ Phone no. (business hours) Mobile no. Fax no. | 07 5449 9600 ‘| | [ 07 5449 9494 | Email address | [email protected] Postal address PO Box 61 NOOSAVILLE QLD Postcode 4566 Licence class Licence number R.P.E.Q. | [ 18877 | Date approval to inspect received from building certifier__ __ 20/07/2020. | 9. Signature of building certifier, competent person or QBCC licensee Note: A building certifier must sign this form for temporary swimming pool fencing under section 4 of Schedule 1 of QDC MP 3.4. Date | | 20/07/2021 | Signature L ——S Gs The Building Act 1975 is administered by the Department of Housing and Public Works
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.