Appendix 1 - Acoustic Fact Sheet
Attached to the e-mail MCU17/0524 - Information Response.
FACT SHEET
The Precast Concrete Handbook gives 150 precast concrete wall as complying
values for various common concrete with the BCA 2004 onwards acoustic
wall arrangements (see Tables 1 and provisions.
2 – which are reproductions of Table 9.8
& Table 9.9 from the Precast Concrete This would be fine if people lived in
Handbook-Sept 2002). Added to the acoustic laboratories, but they do not,
Rw values are the spectrum adaptation they live in real apartments. There are
terms Ctr. some walls that perform well in an
acoustic laboratory but do not perform
When dealing with external noise well when installed. The acoustic
intrusion, particularly traffic noise, there laboratory has precise openings built to
is a rule of thumb used in a number of fine tolerances. This does not exist in the
Australian Standards that the effective field.
dB(A) reduction equals the Rw rating
minus 5. If the Ctr spectrum adaptation There are other walls however that
term is used the dB(A) reduction is likely better accommodate site tolerances and
to be closer to the Rw factored down by experience has clearly demonstrated
the Ctr rating. that precast panels lose very little
performance between that tested in
In the case of external noise intrusion a laboratory and that measured in
the external wall is usually a mixture of the field, assuming that the rest of
solid wall and windows and/or doors. the structure is up to the appropriate
The concrete panel has a typical Ctr acoustic standard. What is more
value of -5 which is very good. If double important is the field performance
glazed windows are used the Ctr value (designated as Dntw). The requirement
could be -10 for that component. It is of the current BCA is that the installed
therefore necessary to examine the performance including Ctr should
composite sound transmission loss of exceed 45 dB. In this regard the precast
the solid wall area together with all the element easily achieves this value with
components that make up that wall, in a field result in the range Dntw + Ctr
order to determine the Ctr value for the equals 47 to 48 dB.
composite construction.
The acoustic laboratory measurement
Performance of 150mm precast is essential and is the first starting point
panels in acoustic design, however it is the
A 150 mm thick precast concrete panel installed result in the finished apartment
is an interesting situation in respect or town house that is vital and will
to compliance with the Building Code become the dominant factor in the
of Australia. The typical laboratory future. As previously said, people do not
performance of a 150 thick precast live in acoustic laboratories, they live
wall is Rw 54 and the Ctr is -5 giving an in apartments and it is there where the
overall rating of Rw + Ctr equalling 49 acoustic performance must be delivered.
dB. Technically this does not comply
with the BCA, which requires 50 dB
and there has been experience with
some certifiers that will not approve a
making precast easy