Council archive · source document
Approved Plans - MCU24 0112 · MCU24/0112
Plans and drawings: the text below has words only, no drawings.
FINISHES LEGEND
CD-01: TIMBER CLADDING
CD-02: METAL SHEETING
APPROVED PLAN
MCU24/0112 A1006 - Overall Street Elevations
CF-01: NATURAL CONCRETE
NOOSA COUNCIL
7 FEBRUARY 2025
FF-01: STONE TILES
FF-02: TIMBER
FF-03: TILES
GL-01: CLEAR GLASS
GL-02: GLASS LOUVRES
MF-01: METAL FINISH (ROOF)
WF-01: MASONRY BRICK WITH TEXTURED RENDER
WF-02: MASONRY BRICK SCREEN
WF-03: TIMBER BATTENS
8M ABOVE NATURAL
WF-04: BASALT STONE CRAZY PAVE MF-01 MF-01 MF-01 MF-01 GROUND LINE AT ROOF
WF-05: BASALT STONE BLOCKS
GL-01 CD-01 GL-01 CD-01 GL-01 GL-01
AC-01: TIMBER FENCE
PROPERTY BOUNDARY
CEILING
PROPERTY BOUNDARY
8.40
LEVEL ONE
CF-01 TOW: 3.800 5.70
CF-01 CF-01 CF-01
TOW: 2.897
TOW: 2.670
GROUND
2110
2.70
1200
RL: 1.470 WF-01 RL: 1.690
NATURAL GROUND LINE
AT FENCE
2500 UNIT D - TYPE 1 UNIT C - TYPE 2 UNIT B - TYPE 2 UNIT A - TYPE 1 2500
SETBACK SETBACK
1 OVERALL ELEVATION - NORTH
DA1001 1 : 200
MF-01 8M ABOVE NATURAL
600 GROUND LINE
AC-02 GL-01 AC-02 GL-01 GL-02 CD-01 AC-02 GL-01 AC-02 GL-01
PROPERTY BOUNDARY
GL-01 CEILING
PROPERTY BOUNDARY
2000 8.40
CF-01 CF-01 CF-01
CF-01 CF-01 LEVEL ONE
7500
1500 5.70
WF-04
4500
WF-03 WF-03 WF-03 WF-04 WF-03 WF-04 WF-04 WF-03 WF-03
+ 2.700
GROUND
+ 2.000 2.70
2500 UNIT A - TYPE 1 UNIT B - TYPE 2 UNIT C - TYPE 2 UNIT D - TYPE 1
STREET2500ELEVATION - SOUTH
LOW LEVEL ACCESS PATH.
REFER PLAN.
SETBACK SETBACK
2 OVERALL ELEVATION - SOUTH
DA1001 1 : 200
24/01/2025 12:27:59 PM
Client Project Name Sheet Name Project No. Date SCALE @A3
100AC-02
Hilton Terrace, Noosaville OVERALL ELEVATIONS WF-05 24016 xx.xx.25 As indicated
CD-01/FF-02/AC-01 WF-01 TOM OFFERMANN
WF-02 FF-01 CD-02 / MF-01 WF-03 GL-02 WF-04 Drawing No.
CF-01
DA1004
Drawn by
GB
Project Address Revision Checked by
©BLIGHT RAYNER ARCHITECTURE PTY LTD ACN 614335956
0 10 0 20 2 30m 6
BlightSet
Document Rayner
ID: 23514021 100 Hilton Tce · TOWNHOUSE DEVELOPMENT APPLICATION 24.01.2025 100 Hilton Terrace, Noosaville, QLD Use figured dimensions only. Do not scale. Check all dimensions on site prior to fabrication or setout.These designs, drawings and specifications are
copyright and must not be used, kept or copied by any means without permission.
02 1:250@A3
SS 16
Version: 1, Version Date: 29/01/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Approved Plans - MCU24 0112Related documentApplication case desk ↗
About this file
- File size
- 5.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.