MATERIALS AND FINISHES
CODE DESCRIPTION FINISH FT3 2m Powdercoated Aluminium Screen XXXX
AWN1 Awning Hood Powder Coated Aluminium Surfmist PV1 Feature Driveway Entry Beauford Crazy Pave
AWN2 Awning Hood Powder Coated Aluminium Surfmist RN1 Render Resene Black White
BAL3 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN2 Render with Sawcuts Concrete Look
BAL4 Solid Balustrade Birch RN3 Render with Sawcuts To Match Surfmist
BAL5 Aluminium and Clear glass balustrade Powder Coated Aluminium Surfmist RN4 Render over cladding Resene Black White
BAL6 Aluminium and Translucent glass balustrade Powder Coated Aluminium Surfmist RN5 Render with Sawcuts over cladding Concrete Look
CLD1 Hardies Oblique XXXX RS1 LYSAGHT Colorbond roof sheet Colorbond Surfmist
CLD2 External Feature Walls - Territory Panel Limed SCN1 Aluminium Batten Screen - angled Powder Coated Aluminium Surfmist
EA CONC Driveway; Exposed Aggregate Concrete Silver Frost SF1 Soffit lining Resene Black White
EG1 Eaves Gutter Stratco Colorbond Surfmist SF2 Soffit lining Pre-finished
EG2 Custom Profile Eaves Gutter Colorbond Surfmist SF3 Soffit lining - Territory Panel Limed
FF1 External Tile Paradise Stone Ivory
FT1 2m High Perimeter Fencing Timber Pailing Resene Black White
FT2 1.4m Screen above Rendered Blockwork XXXX
FT3 2m Powdercoated Aluminium Screen XXXX
4.1 3.1 2.1 1.1
UNIT 102 & 104 A.1 B.1 C.1 D.1
TOWNHOUSE 105 8M HEIGHT LIMIT
UNIT 101 & 103 UNIT 102 & 104 TOWNHOUSE 105
8M HEIGHT LIMIT
RS1 EG2 RS1
EG1 RS1 EG2 EG1 EG1
EG2 EG1
CLD2 CLD1
AWN1 CLD2 AWN1 RN1 AWN1
CLD2 RN5 2400 WINDOW &
W.09 W.03 RN2 W.03 RN2 2400 WINDOW &
W.09 DOOR HEAD HEIGHT TERRACE TERRACE W.03
AD.04 AD.04 DOOR HEAD HEIGHT
CLD1 CLD2 CLD1
RN5
W.06
W.06 UPPER LEVEL
UPPER LEVEL RS1 PERIMETER FENCE CLD2 W.07 UPPER LEVEL
FFL+16.580 BAL4 CLD2 BAL4 CLD1
FFL+16.360 RN2 SHOWN DASHED CLD2 FFL+16.360
RS1 EG1 RS1
EG1 AWN1 RN1
AWN3 AWN3 RN4 AWN3 AWN3 RN4 AWN3
2400 WINDOW &
2400 WINDOW & W.03 W.03 2400 WINDOW &
DOOR HEAD HEIGHT
DOOR HEAD HEIGHT DOOR HEAD HEIGHT
CARPORT
CL CARPORT
W.06 W.06 GARAGE
GROUND LEVEL W.06 GROUND LEVEL RN1
GROUND LEVEL
FFL+13.200 AC
FFL+13.380 AD.01
W.05
FFL+13.200
W.05 RN1 AD.01
RN4 AD.02
AD.09
FINISHED GROUND
NATURAL GROUND NATURAL GROUND FINISHED DRIVEWAY
N BUILDING 1 ELEVATION BUILDING 1 ELEVATION
- Scale 1:100
E
- Scale 1:100
1.1 2.1 3.1 4.1
D.1 C.1 B.1 A.1
8M HEIGHT LIMIT
UNIT 101 & 103
8M HEIGHT LIMIT
TOWNHOUSE 105 UNIT 102 & 104 UNIT 101 & 103
RS1 EG2 RS1 RS1
RS1 EG2
EG2 EG2 EG2 EG1 EG2 EG2
EG2 EG1
SCN1
AWN1 AWN2 AWN2 AWN1 AWN1
2400 WINDOW & CLD2 SCN3 SCN3
RN2 2400 WINDOW &
W.01 W.02 W.02 W.01 DOOR HEAD HEIGHT 2400 WINDOW & W.09 DOOR HEAD HEIGHT
DOOR HEAD HEIGHT
AD.01 AWN1 PRIVACY SCN2
SCN4
CLD1 UPPER LEVEL W.08 UPPER LEVEL
UPPER LEVEL W.12 CLD1 W.10 CLD2
W.07
RN2 FFL+16.580 RS1 RS1 FFL+16.580
FFL+16.360 EG2 EG2
EG1
AWN1 AWN2 AWN2 AWN1 RN4 AWN1
AWN3
2400 WINDOW & RN1 RN1 2400 WINDOW &
PV1 W.01 W.02 W.02 W.01 SHS DOOR HEAD HEIGHT
2400 WINDOW &
DOOR HEAD HEIGHT
DOOR HEAD HEIGHT TERRACE TERRACE
TERRACE
RN1 RN4
GROUND LEVEL GROUND LEVEL
RN1 GROUND LEVEL
FFL+13.380 FFL+13.380
FFL+13.200 AD.04
AD.05 W.04 AD.05 W.04
NATURAL GROUND NATURAL GROUND
FINISHED GROUND
S BUILDING 1 ELEVATION W BUILDING 1 ELEVATION
- - Scale 1:100
Scale 1:100
Notes:
B L A C K Project: Drawing Title: Project No. Drawn By Drawing No.
Rev Date Description Use figured dimensions in preference to scale. Contact information:
1. These drawings represent a concept design for preliminary cost analysis (MAY 2023) and are NOT FOR CONSTRUCTION N 1/12/2023 Council further RFI Issue All dimensions to be varified and checked on
O 5/12/2023 Council further RFI Issue site. These designs, drawings, specifications
PO Box 781 Tewantin Q 4565 79 - 83 Eumundi Noosa Road B1 - ELEVATIONS 202327 PT WD.1.06
2. The drawings and diagrams provided herewith are NOT FOR CONSTRUCTION OR BUILDING APPROVAL and to be used for preliminary D&C tendering only. Architect Registration # 5386 QLD
and the copyright thereof are the property of For CAPITAL PRUDENTIAL
Structure & Services coordination has not been undertaken.
P
Q
24/01/2024
30/01/2024
Council Decision Notice Response
Council Decision Notice Response
Blackwood and must not be used, retained or W O O D Ph: 0416 037 424
[email protected] 79 - 83 EUMUNDI NOOSA ROAD & 26 Scale Date Project Stage Revision
copied without the written authority of
R 4/03/2024 Updated Building Layout Submission Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au HEADLAND DRIVE, NOOSAVILLE QLD 4566 1:100, 1:1 @ A1 4/03/2024 Concept R