Version 3 — March 2013 Form 15—Compliance Certificate for building Design or Specification NOTE This is to be used for the purposes of section 10 of the Building Act 1975 and/or section 46 of the Building Doaulatinn 20Nk USING REGUIaICH 205. RESTRICTION: A building certifier (class B) can only give a compliance certificate about whether building work complies with the BCA or a provision of the QDC. A building certifier (Class B) can not give a certificate regarding QDC boundary clearance and site cover provisions. 1, Property description Street address (include no., street, suburb / locality & postcode) This section need only be completed if 5 Stevens Street ] details of street address and property description are applicable. Postcode 4567 EG. In the case of (standard/generic) 7 TE pool designishell manufacture andlor Lot & plan details (attach list if necessary) patio and carport systems this section aoa eee rea In which local government area is the land situated? The description must identify all land the Noosa Council | subject of the application. The lot & plan details (eg. SP / RP) are shown on title documents or a rates notice. if the plan is not registered by title, provide previous lot and plan details. 2. Description of componentis certified Clearly describe the extent of work covered by this certificate, e.g. all structural aspects of the steel roof beams. Op works, Soil Report Items not certified: Windows and Doors, Balustrading, Pool Fencing Pre-fabricated Roof Trusses, Bracing & Girder Truss Support Roof sheeting or Tiles 3. Basis of certification Data tho Basis Incline ine navtifeate and « AS1170.1 Dead and Live Loads and load Combinations the extent to which Tab ccoctemotn, rules, » AS 4055 Wind Loads for Houses standards, codes of practice and other « AS 4100 Steel Structures publications, were relied upon. e AS1720 Timber Structures e «AS 1684.2 Residential Timber Framed Construction e AS 2870 Residential Slabs and Footings 2 AS 3700 ____ Masonry Structures Loading Criteria: Wind Loading: Region. B Terrain Cat: 2.5 Topographic Class: T4 Shielding: PS — Design Wind Classification: N3 Floor Loading: Internal: 1.5 kPa Balconies: 3.0 kPa 4. Reference documentation ; : ; ’ Clearly identify any relevant documentation, Drawing numbers:- SCG Consulting Engineers - 23360 - OW1 thru OW9 Sc tbe Ba Sa hepa pels) Report numbers:- SCG Consulting Engineers - 23360(S) LOCAL GOVERNMENT USE ONLY Date received Reference Numberis | The Building Act 1975 is administered by the Department of Housing and Public Works
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 1 page
Page 2
5. Building certifier reference number
6. Competent person details
A competent person for building work, means a
person who is assessed by the building certifier
for the work as competent to practise in an
aspect of the building and specification design,
of the building work because of the individual's
experience and qualifications in the
aspect. The competent person must also be
registered or licensed under a !aw applying in
the State to practice the aspect.
If no relevant law requires the individual to be
licensed or registered to be able to give the
help, the certifier must assess the individual as
having appropriate experience, qualifications or
skills to be able to give the help.
if the chief executive issues any gui
assessing a competent person, the building
certifier must use the guidelines when
assessing the person.
Building certifier reference number
Name (in full)
Sean Richardson |
Company name (if applicable) Contact person
SCG Consulting Engineers | | Sean Richardson
Phone no. business hours Mobile no. Fax no.
| 07 5455 5604 | |
| | 07 5455 5696 |
t
Email address
| [email protected]
Postal address
PO Box 1661
Noosa Heads A
Postcode 4567
Licence or registration number (if applicable)
\
7. Signature of competent person
This certificate must be signed by the individual
assessed by the building certifier as competent.
ee
Signature =< ne
Date
i
2410112014
)